Advertisement

Quick Guide NaviPad
GB
Document in original language | 151671 · A002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NaviPad and is the answer not in the manual?

Questions and answers

Summary of Contents for SystemAir NaviPad

  • Page 1 Quick Guide NaviPad Document in original language | 151671 · A002...
  • Page 2 © Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. 151671 | A002...
  • Page 3: Table Of Contents

    ........6 3.1.3 Temperature control .....7 3.1.4 Fan control ......7 3.1.5 Demand control ......7 3.1.6 Fire/smoke ......7 3.1.7 Humidity control ....8 Flow chart .........8 Language..........8 Time Settings........8 Configuration........9 Advanced NaviPad Settings ...... 10 No communication ........11 151671 | A002...
  • Page 5: General

    Editable text and values are shown in blue and differs depending on user level. Important The air handling unit and the NaviPad has to be connected on a local network with the same IP subnet Fig. 1 (1) Home button, (2) USB connection, reboot button, (3) power supply and communication Fig.
  • Page 6: Start-Up Wizard

    Note the serial number on the device (AHU), to be sure that the correct device (AHU) is paired with NaviPad. If the start-up wizard is cancelled it will start again during next power up of the NaviPad, this will continue until start-up wizard is successfully finished.
  • Page 7 General | Table 2 Version: PR1.2 Start-up wizard started ↓ Scan for devices User input ↓ Connect to only devices in Show devices Numbers of devices Set Time & → ← 0 1 → network + system selection menu detected Date overview dashboard >1...
  • Page 8: Key Board

    | General Note: You can always return to system overview dashboard by pressing the home button, figure 1, (1). Key board When a name, value or password need to be changed/written a key board will appear at the bottom of the touchscreen.
  • Page 9: Alarms

    Alarms | Alarms A LED-light in the home button, figure 1, (1) indicate the status of the air handling unit. • Fixed green — Status ok (no active alarms). • Flashing red — Active/returned alarms in one or several air handling units. •...
  • Page 10: Controller Settings

    | Controller settings Controller settings Data & Settings 3.1.1 Operation overview Value of active signals I/O signals and operation mode. • Temperature • Air flow/pressure • CO2 • RH • Heating • Exchanger • Cooler • Recirculation 3.1.2 In- and output status I/O status Total overview of: •...
  • Page 11: Temperature Control

    Controller settings | 3.1.3 Temperature control Settings for temperature. • Limit values • Setpoint for current control type (Example 1) • Min/max limitation • Outdoor temperature values Example 1 Setpoint for current control type 3.1.4 Fan control Settings for fan control. •...
  • Page 12: Humidity Control

    | Controller settings 3.1.7 Humidity control Setpoints and settings for dehumidification and humidification Flow chart Dynamic flow chart of current configured air handling unit. Active sensors and components are visible with values shown in real time. When pressing on values or items marked in blue you will be forwarded to related settings and/or overview page.
  • Page 13: Configuration

    Controller settings | Configuration • System settings • Function configuration (Example 2) • I/O allocation settings • Alarm configuration (Example 3) • PID controllers Example 2 Function configuration To activate a function go to Function activation. Choose function to activate and set the characteristics on the function.
  • Page 14: Advanced Navipad Settings

    Advanced NaviPad Settings Return to system overview dashboard by pressing on the home button, figure 1, (1). Go to and choose Advanced NaviPad settings. Login required — 1111 • Available devices (Example 4) • Change Password • Restore NaviPad Factory Settings (Example 5) •...
  • Page 15: No Communication

    Example 4 Available devices (AHU) The device (AHU) will appear, press the button to select the device to pair it with the NaviPad. If there are several devi- ces (AHUs) at the same IP subnet, a list of available devices will be presented.
  • Page 16 Systemair Sverige AB Industrivägen 3 SE-739 30 Skinnskatteberg, Sweden Phone +46 222 440 00 Fax +46 222 440 99 www.systemair.com...

Table of Contents