Summary of Contents for Chore-Time SUPER-Selector PT 40866
Page 1
SUPER-Selector PT Control ‘ SUPER-Selector Control ™ Part No. 40866 and 40866C Installation and Operation Manual CHORE-TIME EQUIPMENT P.O. BOX 2000 - MILFORD, INDIANA 46542-2000 POWER POINT TUNNEL TEMP HIGH ALARM TEMP ALARM DANGER LOW ALARM TEMP ON TIME ON TIME...
Page 2
‘ Support Information The Chore-Time SUPER-Selector PT Control is designed to be used as a tool to manage ventilation in poultry and livestock applications. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury and/or death.
Page 3
Safety–Alert Symbol This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. Chore-Time equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Signal Words Signal words are used in conjunction with the safety–alert symbol to identify...
Page 4
SUPER-Selector PT Control ‘ Programming the SUPER-Selector PT The SUPER-Selector PT front panel is divided into different areas to clarify the types of programming required. Each of the following must be properly set. 1. Setting stage temperatures, timers, and alarm limits. 2.
Page 5
SUPER-Selector PT Control ‘ Control Sensor CAUTION The Control Sensor reads the temperature and determines which stage the control The Control Sensor is in. must be located in the bird or animal area When the master selector is pointed toward CONTROL SENSOR, the display window being controlled.
Page 6
SUPER-Selector PT Control ‘ the absolute temperature of the stage selected by the stage setting knob. These absolute temperatures cannot be edited. The intent of this feature is to aid the user in determining the absolute temperature of each stage. To change the absolute temperatures of the stages, it is necessary to change the temperature offsets between stages.
Page 7
SUPER-Selector PT Control ‘ Heat A and Heat B There are 2 heat stages, H1 and H2. If both brooders and space heaters were used, a good approach would be to attach the brooders to the HEAT A output and set its stage to H1 and the space heaters to HEAT B with its stage H2.
Page 8
SUPER-Selector PT Control ‘ Assigning Stages to Mode Changes On the left of the control panel is a switch which sets the stage that the control goes from power to tunnel mode. Using this switch, it is possible to force the control to stay in power mode (no tunnel), or force the control into tunnel mode (locked in tunnel).
Page 9
SUPER-Selector PT Control ‘ Unlabeled Master Selector Position DISPLAY WINDOW MASTER SELECTOR TEMP HIGH ALARM TEMP ALARM LOW ALARM TEMP ON TIME ON TIME STAGE #1 GREEN - NORMAL TIMER STAGE #1 TIMER OFF TIME OFF TIME RED - EDIT TEMPERATURE CONTROL SENSOR STAGES...
Page 10
SUPER-Selector PT Control ‘ Calibrating the Sensors Note: This procedure is not normally required. In order to calibrate a sensor, it will be necessary to attach an accurate calibration thermometer directly to that sensor for several minutes. Use the same calibration thermometer for each sensor calibrated. From the factory the sensors should be accurate within ±...
Page 11
Wiring the System Chore-Time recommends limiting the load for each relay to 1 H.P. This is to help insure years of trouble-free operation from your control. There are enough relays that no external contactors are required. Because of the concentration of wires into one box, it is recommend that the wire entry into the box be through conduits(s) as opposed to romex connectors.
Page 12
SUPER-Selector PT Control ‘ Backup Considerations While there are differing backup devices and philosophies, there is one indisputable fact. This control is made from mechanical and electrical devices that have a finite lifetime. The question is not "if", but rather "when", will this control stop functioning correctly.
Page 13
SUPER-Selector PT Control ‘ Case #2 To back up more than one output with a single thermostat, it is necessary to add a relay contact for each output backed up and drive the relay coil(s) from a single thermostat. The figure below reflects a control with two outputs backed up by one thermostat and one DPST added relay.
Page 14
SUPER-Selector PT Control ‘ Output Relay Layout FUSED 230V CONTROL INPUT POWER 230V 50/60 HZ TUNNEL CURTAIN OPEN TUNNEL CURTAIN OPEN TUNNEL CURTAIN TUNNEL CLOSE CURTAIN CLOSE ALARM ALARM POWER POWER MODE MODE TUNNEL TUNNEL MODE MODE HEAT SENSOR HEAT SENSOR HEAT SENSOR...
Page 15
SUPER-Selector PT Control ‘ SUPER-Selector PT Internal Wiring Diagram (sheet 1 of 4) FUSED 230V CONTROL INPUT POWER 230V 50/60 HZ A U X TUNNEL CURTAIN OPEN A U X TUNNEL CURTAIN CLOSE A U X ALARM A U X POWER MODE HEAT...
Page 16
SUPER-Selector PT Control ‘ SUPER-Selector PT Internal Wiring Diagram (sheet 2 of 4) FUSED 230V TUNNEL CONTROL CURTAIN INPUT OPEN POWER 230V 50/60 HZ TUNNEL CURTAIN TUNNEL CLOSE CURTAIN OPEN TUNNEL CURTAIN CLOSE ALARM ALARM POWER MODE POWER MODE TUNNEL MODE TUNNEL MODE...
Page 17
SUPER-Selector PT Control ‘ SUPER-Selector PT Internal Wiring Diagram (sheet 3 of 4) FUSED 230V CONTROL INPUT POWER 230V 50/60 HZ TUNNEL CURTAIN OPEN TUNNEL CURTAIN CLOSE ALARM POWER MODE TUNNEL MODE SENSOR SENSOR 2526-356 MV1532-12 1/98 Page 17...
Page 18
SUPER-Selector PT Control ‘ SUPER-Selector PT Internal Wiring Diagram (sheet 4 of 4) FUSED 230V CONTROL INPUT POWER 230V 50/60 HZ TUNNEL CURTAIN OPEN TUNNEL CURTAIN CLOSE ALARM HEAT POWER MODE HEAT TUNNEL SENSOR MODE SENSOR SENSOR 2526-357 SENSOR 2526-358 SENSOR SENSOR 2526-356...
Page 19
SUPER-Selector PT Control ‘ SUPER-Selector PT Control Part No. 40866 and 40866C SUPER-Selector CHORE-TIME EQUIPMENT Part No. 40866 P.O. BOX 2000 - MILFORD, INDIANA 46542-2000 POWER POINT TUNNEL TEMP HIGH ALARM TEMP ALARM DANGER LOW ALARM TEMP ON TIME ON TIME...
Page 20
Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Equipment, A Division of CTB, Inc. P.O. Box 2000, Milford, Indiana 46542-2000 U.S.A. Phone: 219-658-4101 • E-Mail: ctb@ctbinc.com Printed in the U.S.A.