Manual for panel mount process indicator

Advertisement

Quick Links

USER'S MANUAL
Manual for Panel Mount
Process Indicator
B
R
I R
B -
8
S
- D
Q
E
EQ-DS8B-IRRB
ANKOM INTERNATIONAL
An ISO 9001: 2015 Certified Company
ISO9001:2015
Your Instrument Super Store
Member of SN Registrars (Holdings) Ltd
8327
ISO 9001:2015 CERTIFIED
# 71, Ramachandra Agrahara, Azad Nagar, Chamarajpet, Bangalore - 560 018. INDIA • Phone: 080-2674 1381 Tele/Fax: 080-2674 1382
Website : www.ankom.co.in
E-mail : info@ankom.co.in, sales@ankom.co.in
ANKOM/MAN/IND-36
Page - 1/11

Advertisement

loading

Summary of Contents for Equinox Systems EQ-DS8B-IRRB

  • Page 1 USER’S MANUAL Manual for Panel Mount Process Indicator EQ-DS8B-IRRB ANKOM INTERNATIONAL An ISO 9001: 2015 Certified Company ISO9001:2015 Your Instrument Super Store Member of SN Registrars (Holdings) Ltd 8327 ISO 9001:2015 CERTIFIED # 71, Ramachandra Agrahara, Azad Nagar, Chamarajpet, Bangalore - 560 018. INDIA • Phone: 080-2674 1381 Tele/Fax: 080-2674 1382 Website : www.ankom.co.in...
  • Page 2 When used with Pressure sensor. The Instrument can supply • Applications DC12V auxiliary power & the sensor output is 2mV/V. Select input signal mV. The Instrument can measure any range of Current or Voltage signal input. The user can select data remained or top value remained.
  • Page 3 • Input Signal Specification: • Diagram Connections : Factory Input Signal Range Input Impedance Types Setting A(AA/DA) 0~5A, 0~2A CT configurable Indicate when order 0~1mA, 0~10mA, 4~20mA 4~20mA V(AV/DV) 0~5V, 0~10V, 0~500V 200K DC 0~10V 0~10mV, ±100mV 0~75mV 0~400 , 0~10K 0~400 0.2mA Cu50, Cu100, –50~150°C...
  • Page 4 • Specifications : ower Supply 90~260V AC or 18-30V AC/DC Consumption Accuracy 0.3% F.S. ± 2 digit Analogue Low Value Setting Sampling Rate 8 Times / Second Range : LSP Alarm Relay NO AC 250V/3A or DC 30V /3A cos =1 Input Refer the input signal selection Analogue...
  • Page 5 Press key for more than 3 seconds. can enter / quit from the • Parameter Setting : second grade parameters setting Alarm Setting : In the displaying estate, press and hold SET key for more than 3 seconds, enter alarm mode parameters setting menu.
  • Page 6 • Operation Process : Alarm 2 Setting, Range Power ON Alarm 2 Mode Setting All LED on H : High L : Low Alarm 2 Hysteresis Value Setting Input Signal Type Range : ±50.0 Alarm 3 Setting, Range Up limit Down limit Alarm 3 Mode Setting H : High...