  • Page 1 MIG-V6 seamless switcher User Manual V1.1 △ Before using the product, please read this manual and keep it for future reference. MIG-V6 Series...
  • Page 2 Statement Without the written permission, any corporation or personnel could not copy, imitate, plagiarize or translate this book or part of it. Also could not transmit it in any form or any way(electronic, mechanical, photocopying, recording or other ways) for any business and profitable purpose. The product specifications and information mentioned in this manual is just for reference, will not give prior notice if there is any update.
  • Page 3: Table Of Contents

    ANEL MIG-V6 B · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 9 OARD Control Board ·...
  • Page 4 WARRANTY · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 24 ·...
  • Page 5: Briefs

    Briefs Thanks for your purchasing our MIG-V6 switcher. Do hope you can enjoy the experience of the product performance. The design of the switcher conforms to international and industry standards. But if with improper operation, there will be a personal injury and property damage. In order to avoid the dangerous, please obey the relevant instructions when you install and operate the product.
  • Page 6: Key Features

    Key Features 4 PGM outputs, 16 scaled layers at any position  4 AUX outputs, support mosaic and scaling  3 AUX loop outputs  1 Multi-previewer for monitoring the real-time input and output sources,  customized window layout 1 IP output for real-time monitoring ...
  • Page 7: Using Directions

    Using Directions Accessories Included MIG-V6 accessories User manual Certificate DVI line ×2 DP line×1 Power line ×2 Network cable× ×1 USB disk×1 HDMI line...
  • Page 8: Safety Instructions

    Safety Instructions Please use the correct power voltage, ranging 100~240V AC, 50/60Hz.  Make sure the power is cut whenever pull out any cable from the  machine Make sure the power is off and the signal cables are out before you plug ...
  • Page 9: Function Profile

    4Kx2K/60Hz 4:4:4 options. It allows up to 6 input boards.. It also supports real-time video monitoring for input and output. You can control MIG-V6 via software or console(MIG-H6 or MIG-H8) for fade in/out switching of various layers and presets. This switcher is designed for...
  • Page 10: Technical Specification

    Technical Specification Input signal Input Amount Standards VESA VESA HDMI HDMI-1.3 480i、576i、720p、1080i/p(3G SDI) SDI/VGA SDI×2、VGA×2 Same as SDI and VGA SDI/DVI SDI×2、DVI×2 SDI: 480i、 576i、 720p、 1080i/p (3G SDI) DVI : VESA HDMI/DP HDMI×1、DP×1 HDMI2.0、 DP1.2, 4K2K/60Hz&Custom DP1.1,4K×1K/60Hz&Custom Output signal Output port Amount Resolution...
  • Page 11: Mig-V6

    MIG-V6 The Front Panel 1—Screen:displays the current working status of the machine ,can browse input information、electrical status, etc. 2—Function buttons:Under specific menu ,realize customization function 3—Main buttons :can browse or set menu contents ,Including OK button ,return button and knob.
  • Page 12: The Back Panel

    The Back Panel 1- PGM output 1 11- IP monitoring port 2- AUX output 1 12- F-lock for synchronization between multiple units 3- PGM output 2 13- RS232 4- AUX output 2 14- USB port for upgrading 5- PGM output 3 15- IP control port 6- AUX output 3 16- Link board for cascade and loop the signal...
  • Page 13: Mig-V6 Board

    MIG-V6 Board The control board and output board are included in a standard unit. You can customize the input boards based on your project demand. The output board has 4 types of output port, including PGM output, AUX output, AUX loop output and Multi-previewer output.
  • Page 14: Output Board

    Output Board MIG-V-OUTOSD DVI port Port A is Multiviewer output,port B,C,D are AUX loop outputs Output resolution 1920×1080@60Hz MIG-V-OUTSW DVI port Port A and C are PGM outputs, port B and D are AUX outputs Output resolution 1920×1080@60Hz MIG-V-OUTIP: [IP monitoring] Operation This output board is only for sending the real-time input and mode...
  • Page 15: Input Board

    Input Board MIG-V-INDVI: [DVI×4 input board] Signal format VESA-DVI-D digital signal,support EDID management Port 24+5 pin MIG-V-INHDMI: [HDMI×4 input board] Signal format EIA/CEA-861, HDMI-1.3 Port HDMI, type A MIG-V-INSDI: [SDI×4 input board] Signal format 480i、576i、720p、1080i/p(3G SDI) Port...
  • Page 16 MIG-V-INDP: [DP×2 input board] Signal format DP1.1,3840×1080@60Hz & Custom Port Full size 20 pin MIG-V-INVGA: [VGA×4 input board] Signal format VESA Port 15 pin of D-sub MIG-V-INDP12: [HDMI×1,DP×1 input board] Signal format HDMI2.0,DP1.2,3840×2160@60Hz & Custom Port HDMI type A and full size 20 pin MIG-V-INSDIVGA: [SDI×2,VGA×2 input board] Signal format 2 SDI+2 VGA...
  • Page 17 MIG-V-INSDIDVI: [SDI×2,DVI×2 input board] Signal format 2 SDI+2 DVI Port BNC and 24+5 pin...
  • Page 18: Mig-V6 Menu

    If there is not any setting or the setting is overtime, the machine will stay in the default status. How To Use The Buttons In the front panel of MIG-V6, there are MENU and FUNCTION sections. MENU There are “OK”, ”...
  • Page 19: Default Status

    Default Status After turning on MIG-V6, the screen will show the default window as the below image. 输出板卡 输出信号线已连接 输入板卡 输入信号有效 V6-SWITCHER Input & output board Green part is the output board, blue part is the input board Input port connection...
  • Page 20: Mig-V6 Main Menu

    MIG-V6 Main Menu Press“OK”button, the LCD screen will enter to this window: Menu Status Info Misc Communication Language/语言菜单 About Magnimage There are 5 setting options. Press “OK”for entering, “ ” for returning.
  • Page 21: Status Info

    Status Info Status Info Input Information Output Information Firmware Version Temperature & Fans Electric Report Input Information Page 1/6 1-A 1920×1080 1-B 1920×1080 1-C 1366×768 1-D 1280×1024 2-A 1920×1080 2-B 1920×1080 2-C 1920×1080 Tells the input board information, input connection Input Information and resolution...
  • Page 22 Output Information PRORAM1 AUX PGM1 PROGRAM2 AUX PGM2 PROGRAM3 AUX PGM3 PROGRAM4 AUX PGM4 PREVIEW AUX LOOP1 AUX LOOP2 AUX LOOP3 ETH PVW Output Information Tells the output type...
  • Page 23 Page 1/2 Firmware Version X000e-V6-Sep 6 2018 Output A1587-F9246-9246 Output A1587-F9307-9406 Output A1587-FACC8-ACC8 Output A1587-F9246-9246 Input A1587-F54DA Input A1587-FA0B8 Input A1587-F9003 Temperature & Fans Page 1/2 System Board 28℃ 34℃ Output 45℃ Fan OK Output 43℃ Fan OK Output 44℃ Fan OK Fan OK Output...
  • Page 24: Misc

    Firmware Version Tells the firmware information of the boards Temperature & Fans Tells the temperature and fans status of the boards Electric Report Real-time electric status of the boards Misc Misc LCD Test Pattern Factory Reset LCD Test Pattern Test the LCD screen of V6 Factory Reset Set the machine back to factory status...
  • Page 25: Communication

    Communication Communication Ctrl Board Video On IP Board Ctrl Board IP Address 192.168.1.223 Subnet Mask 255.255.255.0 Apply Cancel Reset Video On IP Board IP Address 192.168.1.237 Subnet Mask 255.255.255.0 Apply Setting Cancel Reset...
  • Page 26: Language/菜单语言

    Ctrl Board To connect MIG-V6 with software or console To display the real-time image of input and Video On IP Board output Default address Control board 192.168.1.223 IP Address IP board 192.168.1.237 Communication Subnet Mask Default address 255.255.255.0 Apply Setting...
  • Page 27: About Magnimage Menu

    About Magnimage Menu About Magnimage Websit Facebook Wechat(Chinese) http://www.magnimage.com/cn/ Website http://www.magnimage.com Wechat(Chinese) Magnimage Facebook(English) Magnimage-ENG...
  • Page 28 Warranty The Whole Unit Warranty One year (from the buying date); If the invoice is lost, the 60 days after the production date will be the warranty start date for the product. Non-warranty Provisions The machine soaking and collisions produced besmirch or surface scratches and other abnormal using causes of malfunction or damage;...

Table of Contents