REINSTALL
BURNER
ASSEMBLY
To reinstall
burner
assembly:
1. Attach flame sensor to burner
assembly.
2. Install HSI and bracket
to burner
assembly.
3. Insert one-piece
burner
in slot on sides of burner
box and
slide burner back in place.
4. Reattach
HSI wires to HSI.
5. Verify igniter
to burner
alignment.
6. For Silicon Nitride
igniters,
see Fig. 21 and 22.
7. For Silicon
Carbide
igniters,
see Fig. 23.
8. Reattach
Flame
sensor wire to Flame
Sensor.
9/3z'__.q
A05025
Fig. 21 - Igniter
Position
- Side View
1-7/8
(47.6 mm)
A05026
Fig. 22 - Igniter Position - Top View
/
F
W32"
8.7 mm
CELL
PANEL
_HOT
SURFACE
IGNITER
ASSEMBLY
IGNITER
7/8,,
22.2 mm
BURNER
_'_
IGNITER
ASSEMBLY
Fig. 23 - Silicon Carbide Igniters
CONVERT
GAS VALVE
A93347
[]NIT
DAMAGE
HAZARD
Failure to follow
this caution
may result in unit damage
The G or J gas valve must
be converted
and pre-adjusted
before
operating
on natural
gas. The
E valves
must
be
pre-adjusted
before
operating
on natural
gas. If left this
way, sooting
and corrosion
will occur
leading
to early heat
exchanger
failure.
FIRE,
EXPLOSION,
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result
in personal
iniury,
death or property
damage.
Gas
supply
MUST
be
shut
off
before
disconnecting
electrical
power
and proceeding
with conversion.