E
D
LECTROSTATIC
ISCHARGE
The SSDs will meet the ESD limits specified in the 61000-4-2 guidelines and the customer's
enhanced ESD procedure. The specification will determine whether the contact or air discharge
method should be used. Performance degradation is defined as a decreased throughput rate. No
data errors are allowed. Table 43 lists the ESD requirements.
Ambient Temperature
Relative Humidity
Atmospheric Pressure
Voltage Level
+/-2 kV
+/-4 kV
+/-6 kV
+/-8 kV
+/-2 kV
+/-4 kV
+/-8 kV
+/-12 kV
+/-15 kV
A
C
CCEPTANCE
RITERIA
The following table lists the acceptance criteria definitions for the ESD limits.
The apparatus will continue to operate as intended, i.e., normal unit operation with no
A
degradation of performance.
The apparatus will continue to operate as intended after completion of the test. However,
B
during the test, some degradation of performance is allowed, provided there is no data lost
or operator intervention to restore apparatus function.
Temporary loss of function is allowed. Operator intervention is acceptable to restore
C
apparatus function.
Note: Hardware failures are not acceptable for any level of the above performance criteria.
76
Zeus
(ESD)
ESD Requirements
Table 43.
Climatic Conditions
o
o
15
C to 35
C
30% to 60%
86kPa (860 millibar) to 106 kPa (1,060 millibar)
Discharge Type
Contact
Contact
Contact
Contact
Air
Air
Air
Air
Air
D
EFINITIONS
Acceptance Criteria Definitions
Table 44.
IOPS
3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0
Pass/Fail Performance Criteria
A
B
B
C
A
A
B
B
C