Download Print this page

ZURN Sundara Z5006.03 Installation, Maintenance, And Parts Manual

Tide triple basin hand washing system

Advertisement

Quick Links

Sundara
Tide Triple Basin
®
Hand Washing System
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Atlanta, GA, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantabi-
lity is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to
a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists
are approximate and are not guaranteed.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
NOTE: The information in this manual is subject to change at any time without notice. Installations may
be performed at different times of construction by different individuals. For this reason, these instructions
should be left on-site with the facility or maintenance manager.
NOTE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
ZURN INDUSTRIES, LLC 5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541
In Canada: ZURN INDUSTRIES LIMITED 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292
Rev. A
Date: 7/27/2018
C.N. No. SAN008319
Z5006.03
Sundara
Hand Washing System
Installation, Maintenance,
and Parts Manual
PATENT(S) PENDING
LIMITED WARRANTY
Prod. | Dwg. No. FV658
Tide Triple Basin
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sundara Z5006.03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZURN Sundara Z5006.03

  • Page 1 NOTE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT. ZURN INDUSTRIES, LLC 5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541 In Canada: ZURN INDUSTRIES LIMITED 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292 Rev. A Date: 7/27/2018 C.N.
  • Page 2 Specifications: Sundara Tide triple basin lavatory system manufactured by Zurn Industries. Lavatory shall be mounted at standard height to ® conform with ANSI, UFAS, TAS and ADA Accessibility Standards. Counter and integral basin to be constructed of Sundara ®...
  • Page 3 Z5006.03 Parts List Item Name Basin Optional Shroud Shroud Wall Bracket Mounting (L) Bracket "Wall Hanger Bracket (Available only for Retrofit)" Solid Top Open Grid Drain Water Supply Items P Trap Assembly Sensor Faucet 10 Soap Dispenser (If Ordered) 11 "5/16-18 Screw for Mounting L Bracket to Basin"...
  • Page 4 Plumbing and Electrical Rough-Ins FV658 Rev. A 7/27/2018 Page 4...
  • Page 5: Required Tools

    Required Tools: Torx Wrench: Socket Wrench: Non-toothed Wrench T10 & T25 5/16” & 3/8” L Brackets Installation For ease of installation, lay basin on its top surface on a cushioned surface. Use socket wrench to torque the screws (approximately 4-5 complete turns bottom out approximately 5 ft-lbs of torque). Warning: Do not overtighten the screws.
  • Page 6 Soap Dispenser Installation For ease of installation, lay basin on its back. Install the soap spout on right or left soap hole as applicable. Refer to soap dispenser installation guide for details. Grid Drain Installation For ease of installation, lay basin on its back. Place grid draininto drainage opening.
  • Page 7 Retrofitting Hanger Bracket Installation Wall Stud Plywood 3 1 2 [89] 3 1 2 [89] 4 [99] 3 1 2 [89] 3 1 2 [89] 4 [99] Bolt supplied by 1 [25] Hanger Bracket installer to attach the plywood to 1 [25] wall studs Wall Stud...
  • Page 8: Installing Mounting Bracket

    Installing Mounting Bracket • Secure the mounting bracket to the plywood cut-out with supplied washers, bolts and toggle an- chors on the plywood. Wall Stud Plywood Mounting Bracket Bolt supplied by installer to attach the plywood to wall studs Warning: Must be handled by at least 3 people Warning: Ensure the basin back edge is completely supported in the wall bracket.
  • Page 9 Installing with Carrier Option Z1240-EZR Carrier System Optional Waste Line Sleeve (-WL) Warning: Must be handled by at least 3 people Avertissement : s’y prendre à trois minimum. Refer to Carrier Rough-in & Installation guide for details. Soap Dispenser Bracket and Bottle Installation Refer to soap dispenser installation guide for details.
  • Page 10: Shroud Installation

    P Trap Installation & Water Supply Connection to Faucet Connect the tail piece to Grid Drain (threaded connection) Then attach P-Trap to tailpiece Adjust the tail piece base on drain outlet on the wall. Shroud Installation: Step 1 Pivot Point Pivot Point •...
  • Page 11 Shroud Installation: Step 2 • Remove the wall bracket and drill 3/4” holes into the center of the holes previously marked. Ensure that wall studs are not immediately behind the marked hole locations prior to drilling. • Install anchor toggle bolts into previously drilled holes in walls. Step 3 •...
  • Page 12 Shroud Installation: Step 4 • Place shroud on hanger hooks of wall bracket as shown. Then, insert each clevis pin through the 2 pivot points. (Note: the shroud will likely need to be rotated upward slightly in order to install each pivot. •...
  • Page 13 Repair Instructions: • Zurn recommends that damages should be repaired by certified solid surface fabricator or repair agents. • Blemishes to the basin surface (such as scratches, burn marks, and minor chipping) can be repaired by sanding with super-fine(800 or 1000 grit) sand paper and/or maroon Scotch-Brite™...