Download Print this page

Tapeswitch PRSU/M2SI Operating Manual page 9

Multifunctional downstream device

Advertisement

Safety related data
EN ISO 13849-1:
Category:
4
PL:
e
MTTF
:
134,5
d
DC
:
99,0
avg
d
:
365
op
h
:
24
op
t
:
3600
cycle
 1
IEC/EN 62061
IEC/EN 61508
IEC/EN 61511:
SIL CL:
3
SIL:
3
HFT
:
1
*)
DC
:
99,0
avg
SFF:
99,6
PFH
:
3,89E-10
D
PFD:
3,27E-05
T
20
1
HFT = Hardware failure tolerance
*)
nfo
The values stated above are valid for the standard type. Safety data for
other variants are available on request.
The safety relevant data of the complete system has to be determined
by the manufacturer of the system.
Demand to our device based on the
evaluated neccessary safety level of
the application.
PL e with
Cat. 3
or Cat. 4
EN ISO 13849-1
PL d with
Cat. 3
SIL CL 3,
SIL 3
IEC/EN 62061,
with HFT = 1
IEC/EN 61508
SIL CL 2,
SIL 2
with HFT = 1
EN 61511, EN 50156-1
SIL 3
Tapeswitch Corporation
e-mail: sales@tapeswitch.com • web: http://www.tapeswitch.com
a (year)
%
d/a (days/year)
h/d (hours/day)
s/cycle
/h (hour)
IEC/EN 62061
IEC/EN 61508 /
IEC/EN 61511
%
%
h
-1
a (year)
Intervall for cyclic test of the
safety function
once per month
once per year
once per month
once per year
once per year
CE-Declaration of Conformity
Approvals and Markings
Phone: 631-630-0442 Toll Free: 800-234-8273
9
TÜV
Baumuster
geprüft
10/2015 EN