Table 13: Environmental tests
Specified service temperature range
Transport and storage temperature range
Operation in dry heat conditions
Operation in dry cold conditions
Damp heat test cyclic
Storage temperature test
Table 14: Encapsulation
REA 101
REA 103
REA 105
REA 107
Table 15: Insulation tests
Dielectric tests according to IEC 60255-5
Impulse voltage test according to IEC 60255-5
Insulation resistance according to IEC 60255-5
Table 16: Electromagnetic compatibility tests
EMC immunity test level meets the requirements listed below:
1 MHz burst disturbance test according to IEC 60255-22-1, class III:
Common mode
Differential mode
Electrostatic discharge test according to IEC 61000-4-2, class IV and
ANSI/IEEE C37.90.3-200:
For contact discharge
For air discharge
Radio-frequency electromagnetic field disturbance test according to IEC 61000-4-3 and
IEC 60255-22-3:
Amplitude-modulated:
Frequency f
Field strength E
Pulse-modulated:
Frequency f
Field strength E
Radio frequency disturbance test according to
IEC 61000-4-6 and IEC 60255-22-6:
Conducted, common mode
Fast transient disturbance tests according to
IEC 60255-22-4 and IEC 61000-4-4
Surge immunity test according to IEC 61000-4-5 and IEC 60255-22-5:
Aux. voltage input, trip outputs:
Line-to-line
Line-to-earth
Signal contacts (IRF), current inputs, RESET input:
Line-to-line
Line-to-earth
Electromagnetic emission tests according to EN 55011 and IEC 60255-25:
Degree of protection, IEC 60529
Weight
Degree of protection, IEC 60529
Weight
Degree of protection, IEC 60529
Weight
Degree of protection, IEC 60529
Weight
REA 10_
1MRS750929-MBG
-10...+55°C
-40...+70°C
According to IEC 60068-2-2
According to IEC 60068-2-1
According to IEC 60068-2-30
r.h. >95%, t = 20...55°C
According to IEC 60068-2-48
IP 20
about 4.6 kg
IP 20
about 1.1 kg
IP 20
about 1.1 kg
IP 20
about 1.0 kg
2 kV, 50 Hz, 1 min.
5 kV, 1.2/50 µs, 0.5 J
>100 MΩ, 500 V DC
2.5 kV
1 kV
8 kV
15 kV
80...1000 MHz
10 V/m (rms)
900 MHz
10 V/m (rms)
10 V, 150 kHz...80 MHz
4 kV
2 kV
4 kV
1 kV
2 kV