LG Multi V Water IV Installation Manual page 17

Variable refrigerant flow water source units 6.0 to 48.0 tons
Hide thumbs Also See for Multi V Water IV:
Table of Contents

Advertisement

Table 9: Triple-Frame 208-230V Heat Recovery Units.
Combination Unit Model Number
Individual Component Model Numbers
Cooling Performance
Nominal Cooling Capacity (Btu/h)
Heating Performance
Nominal Heating Capacity (Btu/h)
Operating Range (Entering Water Temperature)
Cooling (°F)
2
Heating (°F)
Synchronous Operation (°F)
Compressor
Inverter Quantity
Oil/Type
Unit Data
Refrigerant Type
R410A Refrigerant Factory Charge (lbs)
Refrigerant Control/Location
Max. Number Indoor Units/System
Sound Pressure dB(A)
Cooling/Heating
3
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cables
Heat Rejected to Equipment Room (Btu/h)
Heat Exchanger (Stainless Steel Plate)
Maximum Pressure Resistance (psi)
Flow at Rated Condition (GPM)
Range of Flow (GPM)
Total Heat of Rejection (Btu/h)
Total Heat of Absorption (Btu/h)
Pressure Drop (ft-wg)
Δt
(°F)
4
Piping
5
Liquid Line Connection (in., OD)
Low Pressure Vapor Line Conn (in., OD)
High Pressure Vapor Line Conn (in., OD)
Water Inlet/Outlet Connection Size (in)
Condensate Drain (in)
Nominal capacity is outside of AHRI Standard 1230 and based on the following conditions:
1
• Cooling – Indoor 80°F DB / 66°F WB
Water Temperature Entering: 86°F
• Heating – Indoor 68°F DB
Water Temperature Entering: 68°F
When entering water temperature is lower than 59ºF, variable water flow control kit PWFCKN000
2
is required.
ARWB Series Heat Recovery Water Source Unit Specifications
ARWB360BAS4
ARWB072BAS4 x 1 + ARWB144BAS4 x 2
1
1
HSS DC Scroll x 3
PVE/FVC68D
12.8 + 12.8 + 12.8
EEV/Indoor Unit
2
280 + 280 + 280
302 + 302 + 302
35.5 + 35.5 + 20.3
36.5 – 137.0
94,400 + 190,100 + 190,100
73,200 + 145,200 + 145,200
3.7 + 9.2 + 9.2
3/8 + 1/2 + 1/2 Braze
7/8 + 1-1/8 + 1-1/8 Braze
3/4 + 3/4 + 3/4 Braze
(1-1/2 + 1-1/2 Fem) x3
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
30.0 Ton
360,000
405,000
23 – 113
14 – 113
23 – 113
R410A
58
56/57
2 x 18 AWG
7,480
640
10.4
3/4 Female
Sound pressure levels are tested in an anechoic chamber under ISO 3745 standard.
3
Value is calculated as follows: Δt = Total Heat of Rejection/(Nominal Flow Rate x 500).
4
Refer to the Refrigerant Piping section of this manual for correct line sizing. Contractor must use LG
5
manufactured Y-Branch and Header Kits only. Designer must verify refrigerant piping design configura-
tion using LG's computerized refrigerant piping software (LATS Multi V) to validate the pipe design.
GENERAL DATA
36.0 Ton
ARWB432BAS4
ARWB144BAS4 x 3
432,000
486,000
23 – 113
14 – 113
23 – 113
HSS DC Scroll x 3
PVE/FVC68D
R410A
12.8 + 12.8 + 12.8
EEV/Indoor Unit
64
58/62
280 + 280 + 280
302 + 302 + 302
2 x 18 AWG
7,992
640
35.5 + 35.5 + 35.5
42.6 – 159.8
190,100 + 190,100 + 190,100
145,200 + 145,200 + 145,200
9.2 + 9.2 + 9.2
10.7
1/2 + 1/2 + 1/2 Braze
1-1/8 + 1-1/8 + 1-1/8 Braze
3/4 + 3/4 + 3/4 Braze
(1-1/2 + 1-1/2 Fem) x3
3/4 Female
17