Safety Precautions ..................4 Explosion Protected Type Specifications ..........10 How to Use Online Manual ............... 23 Preparation to Install YFGW710 Attached Software ......23 Copyright and Trademark Notices ............24 About User’s Manual ................. 25 Information of User’s Manual Revision ..........25 YFGW710 Software License Agreement ..........
This manual (IM 01W01F01-11EN) describes the safety precautions, explosion protected type specifications and the license agreement of attached software for the YFGW710. There are three documents including this one for the YFGW710 listed below. Read them along with this manual.
Page 3
<Read Me First> ATEX Documentation This is only applicable to the countries in European Union. IM 01W01F01-11EN...
If any protection or safety circuit is required for the system controlled by the product or for the product itself, prepares it separately. Be sure to use the spare parts approved by Yokogawa Electric Corporation (hereafter simply referred to as YOKOGAWA) when replacing parts or consum- ables.
Page 5
(d) Maintenance • Please carry out only the maintenance procedures described in this manual. If you require further assistance, please contact the nearest Yokogawa office. (e) Explosion-Protected Instrument • Users of explosion-protected instruments should refer first to “Explosion Proof Specification”...
Page 6
If you need to repair or modification, please con- tact the nearest Yokogawa office. (f) Modification • Yokogawa will not be liable for malfunctions or damage resulting from any modification made to this instrument by the customer. (g) Product Disposal •...
Page 7
Insulation Resistance and Dielectric Strength Test Insulation Resistance and dielectric strength test could not be carried out for YFGW710, due to the circuit ground is connected directly to the frame of YFGW710 via RF cable shield. IM 01W01F01-11EN...
Yokogawa Electric Corporation. Radio and Telecommunications Terminal Equipment Directive (R&TTE) We, Yokogawa Electric Corporation hereby declare that this equipment, model YFGW510 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The CE declaration of conformity for R&TTE for this product can be found at http://www.
Page 9
<Read Me First> NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interferences to radio com- munications.
<Read Me First> Explosion Protected Type Specifications CAUTION This instrument has been tested and certified as being explosion protected. Please note that severe restrictions apply to this instrument’s construction, installation, external wiring, maintenance and repair. A failure to abide by these restrictions could make the instrument a hazard to operate.
Page 11
• To satisfy type of protection and NEMA4X, apply suitable devices to the electrical connec- tion port. • YFGW710 does not have a power switch inside. Prepare a dedicated breaker for the exter- nal power line to turn ON/OFF the device.
Page 12
The type of electrical connection is depends on the model code suffix. The model code suffix is shown on the main label in front of YFGW710. The second character following the letter A shows the type of electrical connection as below.
Page 13
Information of Installation Guidance) and IM (User’s Manuals) should be referenced and the instructions described in the documents should be observed. • YFGW710 does not have the Nonincendive Field Wiring. The conduit wiring is required for the power cable and the metal network cable to be connected to YFGW710.
Page 14
The type of electrical connection is depends on the model code suffix. The model code suffix is shown on the main label in front of YFGW710. The second character following the letter A shows the type of electrical connection as below.
Page 15
Care should be taken to avoid multi-point earthing since the equipment is not galvanically isolated from the power supply. • YFGW710 does not have a power switch inside. Prepare a dedicated breaker for the exter- nal power line to turn ON/OFF the device.
Page 16
WARNING • The instrument modification or parts replacement by other than authorized Representative of Yokogawa Electric Corporation is prohibited and will void the EHSRs. • When Opening the cover, the enclosure should be dry and clean to prevent from ingress water or dust.
Page 17
Specified supply voltage and wattage. NO.: Serial number and year of production YOKOGAWA TOKYO 180-8750 JAPAN: The manufacturer name and the address The third figure from the last of the serial number shows the year of production. For example, the production year of the product engraved in “NO.”...
Page 18
The type of electrical connection is depends on the model code suffix. The model code suffix is shown on the main label in front of YFGW710. The second character following the letter A shows the type of electrical connection as below.
Page 19
Care should be taken to avoid multi-point earthing since the equipment is not galvanically isolated from the power supply. • YFGW710 does not have a power switch inside. Prepare an dedicated breaker for the exter- nal power line to turn ON/OFF the device.
Page 20
WARNING The instrument modification or parts replacement by other than authorized Representative of Yokogawa Electric Corporation is prohibited and will void the certification. • When Opening the cover, the enclosure should be dry and clean to prevent from ingress water or dust.
Page 21
Specified supply voltage and wattage. NO.: Serial number and year of production YOKOGAWA TOKYO 180-8750 JAPAN: The manufacturer name and the address The third figure from the last of the serial number shows the year of production. For example, the production year of the product engraved in “NO.”...
Page 22
<Read Me First> Ground Cable Connection The grounding terminals are located on the inside and outside of the terminal area. Connect the cable to grounding terminal in accordance with wiring procedure 1) or 2). 1) Internal grounding terminal 2) External grounding terminal If the power cable is a shielded cable, the shield should be grounded at the terminal marked...
<Read Me First> How to Use Online Manual It is necessary to install Adobe Acrobat Reader to read the instruction manual (YFGW710 Field Wireless Integrated Gateway: IM 01W01F01-01EN). Install the following Adobe Reader by the administrator authority. • Adobe Reader 9.3 or later Adobe Reader can be downloaded from the Web site of Adobe Systems Incorporated.
Trademark Acknowledgments • CENTUM, PRM, FieldMate, STARDOM and VigilantPlant are either trademarks or regis- tered trademarks of Yokogawa. • Microsoft, Windows, Windows Server, Windows Vista, Visual Basic, Visual C++, Visual Studio and Microsoft NET Framework 3.5 are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
The following printed user’s manual is attached to YFGW710 hardware. • IM 01W01F01-11EN: YFGW710 Field Wireless Integrated Gateway Read Me First The following online user’s manual is stored in the attached DVD-ROM for YFGW710. • IM 01W01F01-01EN: YFGW710 Field Wireless Integrated Gateway Information of User’s Manual Revision...
Yokogawa or licensors to Yokogawa. Ownership of and all the rights in the Software Product shall be retained by Yokogawa or the licensors and none of the rights will be transferred to you hereunder.
Page 27
Software Product is installed. 4.4 The above warranties shall not be applied to and Yokogawa shall not be liable for the defect or noncompliance which is subject to any of the following circumstances: a) the hardware on which the Software Product is installed has ceased to be covered by the warranty or maintenance contract of the hardware supplier;...
Page 28
Yokogawa out of court. The foregoing obligation and indemnity of Yokogawa shall be subject to that i) you promptly notify Yokogawa of the Claim in writing as provided above, ii) you grant to Yokogawa and its designees the full authority to control the defense and settlement of such Claim and iii) you give every and all necessary information and assistance to Yokogawa upon Yokogawa's request.
Page 29
10. Audit; Withholding 10.1 Yokogawa shall have the right to access and audit your facilities and any of your records, including data stored on computers, in relation to the use of the Software Product as may be reasonably necessary in Yokogawa's opinion to verify that the requirements of this Agree- ment are being met.
Need help?
Do you have a question about the YFGW710 and is the answer not in the manual?
Questions and answers