Page 1
K5 ES HP PX CONDENSING DRIER USER MANUAL...
Page 2
DO YOU HAVE ANY QUESTIONS OR DO YOU NEED OUR SUPPORT? Please visit www.corroventa.com or call us at +44 (0)161-244 95 23 and speak to an expert. We have the knowledge and the equipment to find a solution as efficiently as possible.
K5 ES HP PX has a built-in pump to allow continuous operation and a bucket for occasions when it is difficult to get rid of condensation water. K5 ES HP PX is compatible with and can be used together with Supervision for remote control and monitoring.
These user instructions contain information protected by copyright laws. No part of this document may be reproduced, stored in an information storage system or transmitted in any way or by any means without Corroventa AB's written consent. Any comments regarding the content of this document must be sent to:...
20. The dryer must not be used with accessories other than those described in this manual or approved by Corroventa Avfuktning AB. 21. The dryer must be placed at a distance of at least half (0.5) a metre from walls and ceilings to ensure that air can circulate.
Overview, controls and connections The images below show Corroventa K5 ES HP PX with its external parts and controls. Connectors for hose Folding handle/ connection Carry handle Process air filter Bucket Filter Durable feet that allow stackability and prevent damage to surfaces.
Electrical connection The machine is connected to the earthed 230V/50Hz socket. K5 ES HP PX can be connected to a 10A, max 16A, fuse. Electronic control delays the start max 2 minutes. Starting and operating • Operating range humidity: 30-100% RH •...
Via the control panel, the user of K5 ES HP PX can optimise the operation for the intended job, set the capacity and volume, control the fan as well as use integrated or external sensors for temperature and relative humidity to achieve the desired effect in combination with the lowest possible energy consumption.
ES product family, menus and operation K5 ES HP PX has an easy-to-use user interface with a display and five buttons. The two larger buttons on each side of the display are used to select between different menus. These buttons are only intended for navigation and cannot be used to change the settings.
Page 14
Start view Normal start When K5 ES HP PX starts up, two options appear for the user on the display: Start: Starts the machine with standard settings, continuous operation with maximum capacity. Previous settings such as use of sensor control, timer etc.
Page 17
Capacity mode The drying capacity of K5 ES HP PX can be optimised for a given work task and situation with three different operating modes. When setting MAX (maximum) the machine works to remove as much water as possible. If the machine's...
Page 18
Timer K5 ES HP PX has an integrated timer function that allows the user to determine when the machine is to run. When the timer function is used, the word Timer appears in the standard view's upper, right-hand corner according to the graphic to the right.
Control mode and hysteresis In addition to the normal, continuous drying operation, the operation of K5 ES HP PX can also be controlled via its built-in sensors for relative humidity and temperature as well as via its external hygrostat or external, networked sensor.
Internal fault. If the alarm remains, contact a service technician. Network functions As a member of the new ES product family, K5 ES HP PX can be included in a network together with other turbines and adsorption dehumidifiers with several functions, such as for example •...
Accessories and consumables The following parts are available as accessories and consumables for K5 ES HP PX: Part number Designation 1003146 Condensation water filter 1002827 Process air filter Fault tracing Fault symptom Probable cause Actions The capacity of the dryer seems Low ambient temperature or Check relative air humidity.
Technical data K5 ES HP PX Operating range, RH, % 30-100% Operating temperature range, °C +3 - +38 700 (incl. additional heater: Rated output, W 2000) Extra heater W 1300 (full temperature control) Actual output at 20°C,60% RH W Max Capacity, l/day Capacity 30°C, 80% RH, l/day...
Page 34
DO YOU HAVE ANY QUESTIONS OR DO YOU NEED OUR SUPPORT? Please visit www.corroventa.com or call us at +44 (0)161-244 95 23 and speak to an expert. We have the knowledge and the equipment to find a solution as efficiently as possible.
Need help?
Do you have a question about the K5 ES HP PX and is the answer not in the manual?
Questions and answers