Download Print this page

Imbera 5341211 Series How-To Manual

How to change the door opening direction

Advertisement

Quick Links

HOW TO CHANGE THE DOOR OPENING DIRECTION?
1
2
3.
3
4
1.
Remove the front
grill.
2.
Disconnect the
red and black wires
that come out of
the door.
Using a set of
pliers remove the
safety pin from the
selfclosing
cartridge.
4.
Unscrew the 3 hex
head screws and
remove these, the
same with the star
washers.
This instructive applies for the series from:
G319 series 5341211XXXXX
VR10 series 6071112XXXXX
VR12 series 6361112XXXXX
5.
RI-13-008 CHANGE THE DOOR OPENING DIRECTION _R0
5
Remove door from the
cooler and remove the
screws to take out the
bushing that is inside the
door frame.

Advertisement

loading

Summary of Contents for Imbera 5341211 Series

  • Page 1 HOW TO CHANGE THE DOOR OPENING DIRECTION? This instructive applies for the series from: Remove the front G319 series 5341211XXXXX grill. VR10 series 6071112XXXXX VR12 series 6361112XXXXX Disconnect the red and black wires that come out of the door. Using a set of pliers remove the safety pin from the selfclosing...
  • Page 2 HOW TO CHANGE THE DOOR OPENING DIRECTION? 6-7. Repeat the same operation by unscrewing and remove the self-closing cartridge. Switch plastic bushing to self-closing side and vice versa. Remove the top cap. On the bottom insert the wires into the door frame.
  • Page 3 HOW TO CHANGE THE DOOR OPENING DIRECTION? 13. Place the door at an “open position” on the cooler, first on the upper hinge, then on the bottom one (make sure the square washer remains on final position). 16. Pass the red and black wires through the tie and 14.

This manual is also suitable for:

6361112 series6071112 seriesVr10G319Vr12