3.1 Unpacking

Inspect shipment for obvious damage then carefully check for other possible shipping damage
such as bent or loose connections that may result in signal leakage.
suspected, notify Cable AML and the shipper before proceeding with installation of the
equipment.
Transmitters shipped installed in a standard EIA Enclosed Equipment Relay Rack may have
foam blocks inserted between modules inside the rack to protect the unit during transportation.
These blocks must be removed before operation otherwise they will impede the flow of cooling
Check the packing list against the parts shipped and verify that the correct material has been
received. Communicate any discrepancies to Cable AML immediately.

3.2 Location

All transmitters should be installed in an area with adequate ventilation to provide the necessary
airflow into the unit.
Position floor-mounted enclosed equipment racks on a flat surface with enough space at the
rear to swing open the access door.

3.3 Input Voltage Requirements

Cable AML transmitters can be equipped to operate on either 120 or 240 VAC at either 50 or 60
Hz. This option is specified by customer request, and each unit is shipped according to this
specification. Some 220/240 VAC units can be connected directly to 220/240 VAC power mains
and some utilize step-down transformers furnished with the unit. If the local power mains are
220/240 VAC and the unit is shipped with a step-down transmitter, connect the mains to
the transformer only!

3.4 Operating and Diagnostic Connections

Figure 4 shows the locations of connectors on the rear and front panels of the transmitter.
Operating Connections
RF Output - The transmitter's output connector on the rear panel is type N coaxial, to
which the output cable to the transmit antenna is connected.
RF Input - The transmitter's input connector on the rear panel is type F female, to
which the VHF inputs are connected.