Field Strength Meter or a TV monitor. The ITX02-2000 transmitter can be equipped to operate on either 120 or 240 VAC at 50 or 60 Hz. This option is specified by customer request, and each unit is shipped according to this specification.
Indoor Broadband Transmitter – ITX02-2000 Reading From 11.5 to 12.5V DRIVER Reading From 0.7 to 1.7V IPS1 TX RF IPS2 Reading From 0.7 to 1.7V AMP 4 IPS3 Reading From Reading From AMP 3 AMP 1 –85 to -200V 0.7 to 1.7V...
Indoor Broadband Transmitter – ITX02-2000 2.0 CIRCUIT DESCRIPTIONS The ITX02-2000 Transmitter consists of the following circuits or modules: MMDS Transmitter Driver Power Amplifier Power Supply System (three +12 VDC current sharing modules and one +24 VDC power supply) Monitoring and Diagnostic Circuits - connectors and switches.
The output connector is designed for use with diagnostic test boxes such as the Cable AML DTB - 1, the WRM-2, or the RM-2A. The test points and corresponding connector pin connections are shown in the Transmitter Block Diagram.
Indoor Broadband Transmitter – ITX02-2000 DC Voltage Diagnostics - DC voltage diagnostic signals can be read using the built- in meter on the front panel. The functions available on the front panel is shown below: +12 VDC of Driver power supply (volts)
3.3 Input Voltage Requirements Cable AML transmitters can be equipped to operate on either 120 or 240 VAC at either 50 or 60 Hz. This option is specified by customer request, and each unit is shipped according to this specification.
Indoor Broadband Transmitter – ITX02-2000 VHF SIGNAL MMDS TX-2000 TRANSMITTER AC POWER Figure 6. MMDS Installation Block Diagram. AC Power Connections This unit is equipped with an AC power cord that is wired for single-phase operation. It is necessary to attach a plug to the power cord before putting the unit into operation.
Indoor Broadband Transmitter – ITX02-2000 SINGLE PHASE WIRING GROUND NEUTRAL HOT or (WHITE or MAIN EARTH BLUE) (BLACK or (GREEN or BROWN) GREEN/YELLOW) THREE PHASE WIRING GROUND NEUTRAL HOT or (WHITE or MAIN EARTH BLUE) (BLACK or (GREEN or BROWN) GREEN/YELLOW) Figure 7.
Indoor Broadband Transmitter – ITX02-2000 Diagnostic Connections Diagnostic connections, not essential to the normal operation of the transmitter, are made at the front panel of the transmitter. • RF Diagnostics - Two RF test point output "N" connectors for Driver RF output and Transmitter Monitor output are provided on the front panel.
To properly operate the transmitter, simply apply the required AC power and input signal. The ITX02-2000 transmitter can be equipped to operate on either 120 or 240 VAC at 50 or 60 Hz. This option is specified by customer request, and each unit is shipped according to these specifications.
Indoor Broadband Transmitter – ITX02-2000 4.2 Ambient Conditions The ITX02-2000 transmitter is designed to operate with no external cooling devices. Internal cooling fans maintain component temperatures at desirable levels when ambient conditions are in the range specified in Section 6.0 - Specifications.
Indoor Broadband Transmitter – ITX02-2000 5.0 MAINTENANCE & TROUBLESHOOTING 5.1 Maintenance Input and output power levels should be measured periodically and adjustments made if necessary. The output power level should be measured and adjusted as described in Section 4.0 of this manual.
Page 25
Indoor Broadband Transmitter – ITX02-2000 Lack of Driver +12 VDC If internal trouble shooting is required due to lack of +12 VDC in the external DC diagnostic test then check for internal +12 VDC on the terminal strip. If 12 VDC is missing, first disconnect the wires from the power supply output terminals and recheck the voltage.