Freddy OF100 16.1.12 16/1/12 23:19 Page 2 Contents General Description / Physical Specification Page Overview General Description / Physical Specification 1.1.1 Greenwoods OF100GIP is an intermittent or continuously running extract fan, designed to Installation Instructions offer a simplistic approach to meet Building Regulations and provide an energy efficient domestic ventilation solution to improve indoor air quality in dwellings.
Page 3
Freddy OF100 16.1.12 16/1/12 23:19 Page 4 Greenwood HumidiSMART monitors the ambient humidity within the wet room environ- 1.1.6 The appliance is not intended for use by young children or infirm persons unless they have ment and looks for short peaks of humidity made by either cooking, showering or bathing. been adequately supervised by a responsible person to ensure that they can use the This smart technology ensures that your OF100GIP is only running when required, removing appliance safely.
Freddy OF100 16.1.12 16/1/12 23:19 Page 6 Installation Instructions General Preparation 2.1.2 The OF100GIP fan is supplied with a 100mm nominal spigot for connection of ducts for installation. 2.1.1 The OF100GIP fan has been supplied ready for installation, consisting of three main 2.1.3 100mm diameter rigid duct should be used to provide the best performance levels required component sections:...
Page 5
Freddy OF100 16.1.12 16/1/12 23:19 Page 8 2.2.2 The unit must be securely mounted using all four fixing holes provided. (see Figure 1). Using screws provided, ensure For control panel access ensure a minimum of Using the four fixing screws, secure fan body to Position grille assembly onto back plate and secure 100mm free space is left between side of the wall.
Page 6
Freddy OF100 16.1.12 16/1/12 23:19 Page 10 2.5.5 Flexible Ducting - Ensure ducting lengths are kept to a minimum and ducting is pulled taut so that it is smooth and straight. Where bends are necessary, and where ducting is run in restricted areas, ensure the ducting is not crushed.
Freddy OF100 16.1.12 16/1/12 23:19 Page 12 2.6.7 The fan must not be mounted above or closer than 1m to the cooker where it could be Conversion to SELV affected by excessive heat or moisture. 2.7.1 The installation must be carried out by a qualified electrician. 2.6.8 Fan Specifications 2.7.2...
Freddy OF100 16.1.12 16/1/12 23:19 Page 14 • Insert mains cable (A) and clamp using cable clamp provided (B). On Site Commissioning / Set Up From 3.1.1 This section covers set up, configuration of the unit for installation (either intermittent or continuous running) To OF100 GIP mains and altering pre-set factory settings.
Freddy OF100 16.1.12 16/1/12 23:19 Page 16 How Your Fan Can Be Installed Intermittent Mode Continuous Mode How It Works How It Works • • Pullcord turns fan on / off. Automatic switch off after 2 hours. • Pullcord turns fan to boost / trickle. Automatically returns to trickle after 2 hours. •...
All information is believed correct at time of going to press. E&OE. All goods are sold according to Greenwood Air Management Ltd’s Standard Conditions of Sale which are available on request. All dimensions referred to are in millimetres unless otherwise shown.
Page 11
Freddy OF100 16.1.12 16/1/12 23:19 Page 20 Greenwood Air Management Ltd Greenwood House, Brookside Avenue, Rustington, West Sussex, BN16 3LF Main Line Tel: +44 (0) 1903 771021 Technical Services: +44 (0) 1903 777135 Main Line Fax: +44 (0) 1903 782398 Web: www.greenwood.co.uk...