Commissioning

Assigning Programming ADD and DELETE Key-sticks
In the simple operating mode the Programming ADD and DELETE
Key-sticks must be assigned during commissioning.
Attention!
Ö In order to prevent abuse of the electronic keys by unauthorised
persons: keep Programming ADD and DELETE Key-sticks in a
safe place.
1. Get the green Programming ADD Key-stick and the red DELETE
Key-stick ready.
2. Switch on the Door Terminal Basic by pressing the white button
on the display. The green LED blinks for a few seconds.
3. Hold the green Programming ADD Key-stick in front of the Door
Terminal Basic while the green LED is blinking. The green LED
lights up in confirmation. After removal of the green Programming
ADD Key-stick the red LED blinks.
4. Hold the red Programming DELETE Key-stick in front of the Door
Terminal Basic while the red LED is blinking. The red and green
LEDs light up simultaneously. The Door Terminal Basic switches
off automatically.
If errors crop up during assignment:
Ö Switch on the Door Terminal Basic again.
Ö Assign the Programming ADD and DELETE Key-sticks again.
If errors re-occur:
Ö Contact the Dialock sales office.