1.3 Standard Equipment/Components

Your system will come with the following equipment included:
1. W.E.S base station
2. Signaling transmitter
1.3.1
W.E.S Base
The W.E.S. base is a polycarbonate enclosure housing status lights, stop button, reset button
antenna and mounting points.
Internally there is a user replaceable 250V 15A Fuse
1.3.2
Signaling transmitter
The signaling transmitter may be one of a handful of transmitters designed for functionality in
different environments. See documentation specific to the handheld device assigned to your
base unit.
Note: The handset and and a W.E.S. unit are normally configured to work together. Some
units are programmed to restrict which handsets will trigger the alarm state. Always test and
ensure you are using the correct handset for your system. If in doubt test it to ensure it will
work.

2 Installation

See Helios W.E.S. E5 Install Guide

3 Operation

3.1 Base Unit:
When power is supplied to the base unit the red "Alarm" LED will be on, And the relay contacts will be
open (In the alarm state the output relay contacts will be open). The base unit will always start in the
"Alarm" state when powering up.
To Enable: Press and hold the "Reset Button" until the green "Enable" led comes on and the red
"Alarm" LED goes out. (In the enable state the output relay contacts are closed)
If the panel will not turn on the "Enabled" light when pressing the reset button, check to ensure the
push stop button is not depressed or that there are no handsets with an active alarm.
While the system is displaying the green "Enabled" LED the relay contacts are closed and the equipment
wired to the base should be functional depending on your installation and procedures.
Activating the E-Stop Alarm
An E-Stop can be initiated in two ways, locally via the E-stop switch located on the front of the unit and
remotely via the wireless remote.
Pressing the Large Red E-stop button on the face of the unit will open the relay contact, the
"Alarm" LED will come on and the "Enable" LED will turn off.