Download Print this page
KERN ORA 1UA Operating Manual

KERN ORA 1UA Operating Manual

Analogue refractometer

Advertisement

Quick Links

Operating manual

Analogue refractometer
KERN ORA 1 UA/UB UREA AdBlue Basic
ORA 4 UA/UB UREA AdBlue Combi
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Contents
1

technical data.................................................................................................1

2
Description......................................................................................................2
3

General information .......................................................................................3

3.1 Intended use ...................................................................................................3
3.2 Warranty..........................................................................................................3
4
Basic safety information ...............................................................................4
4.1 Follow the instructions in the operating manual .......................................4
4.2 Warning ........................................................................................................4-5
5
supplied items ................................................................................................5
6
Before the first use ........................................................................................6
7
Use/measurement ........................................................................................6
7.1 Zero point calibration ................................................................................ 7-8
7.2 Additional advice ............................................................................................9
7.3 Measuring procedure ...............................................................................9-10
8
Cleaning and maintenance ........................................................................ 11
9
storage ........................................................................................................ 11
10 service ........................................................................................................ 12
11 Disposal ........................................................................................................ 12
12 Additional information ................................................................................ 12
1. technical data
1 Technische Daten
Abmessungen
Mo d e lle
Mes s bereic h
S kalen-­‐
Models
Measuring range
K E R N
und
t eilu ng
S kalen
Genau ig keit
and Scales
KeRn
160x40x40mm
O R A 1 U B
0 -­‐4 0 % Urea
0 ,2 % Urea
160x40x40mm
O R A 4 U B
Urea: 3 0 -­‐
0 ,2 % Urea
3 5 %
1 °C
EG:   -­‐5 0 °C –
1 °C
oRA 1UA/UB
0-40 % urea
0 °C
5 °C
PG:   -­‐5 0 °C –
0 ,0 1   kg / l
0 °C
urea: 30-35%
C W:   -­‐4 0 °C –
EG: -50°C – 0°C
0 °C
oRA 4UA/UB
BF: 1 ,1 0 –
PG: -50°C – 0°C
1 ,4 0   kg / l
CW: -40°C – 0°C
BF: 1,10 – 1,40 kg/l
Beispiel der Skala für den ORA 1 UB
Example scale
on
ORA 1 UB
2 Gerätebeschreibung
3
2. Description
2 Gerätebeschreibung
2
3
3
1
6
2
1. Prismenabdeckung
2. Prismenfläche
1
3. Justierschraube
4. Okular mit Gummi-Augenmuschel
5. Einstellring des Diopters
6. Optische Röhre mit Gummigriff
1. Prismenabdeckung
2. Prismenfläche
9
3. Justierschraube
4. Okular mit Gummi-Augenmuschel
8
5. Einstellring des Diopters
6. Optische Röhre mit Gummigriff
8
7
7. Aufbewahrungsbox
8. Pipette
9. Refraktometer
Betriebsanleitung
Analoges Refraktometer
KERN
ORA 1 UB
ORA 4 UB
Version 1.0
12/2014
with antifreeze
Tel: +49- [ 0 ] 7433-9933-0
Fax: +49- [ 0 ] 7433-9933-149
Internet: www.kern-sohn.com
ORA_1UB_4UB-BA-d-1410
Nettogewicht
Produkt
Scale gradua-
Dimensions
tions Accuracy
Product
0,140kg
0,140kg
0,2 %
160x40x40mm
0,2 %
1°C
1°C
160x40x40mm
5°C
0,01 kg/l
Beispiel der Skala für den ORA 4 UB
Example scale
on
ORA 4 UB
4
ORA_1UB_4UB-BA-d-1410
1. Prism cover
4
5
2. Prism surface
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
5
6. Optical tubes with rubber grip
6
ORA_1UB_4UB-BA-d-1410
7. Storage box
8. Pipette
9. Refractometer
10
10. Calibration liquid
11
(Distilled water)
9
11. Adjustment tool
12
12. Cleaning cloth
10
11
3. General information
GB
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index of
transparent substances in the liquid or the solid state. It is used to observe the
KERN & Sohn GmbH
Ziegelei 1
Tel: +49-[0]7433- 9933-0
D-72336 Balingen
Fax: +49-[0]7433-9933-149
E-Mail: info@kern-sohn.com
Internet: www.kern-sohn.com
behaviour of light as it passes from a prism with known properties to the substance
being tested.
Use of the refractometer for other purposes is contrary to its intended use and may
UREA AdBlue Basic
be hazardous. The manufacturer shall not be liable for any damages caused
UREA AdBlue Kombi
by improper use.
mit Antifrost
3.2 Warranty
The warranty shall be void in the event of:
4. Basic safety information
4.1 Follow the instructions in the operating manual
4.2 Warning
▸ Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
▸ Thoroughly clean the refractometer after each use.
▸ The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
▸ This refractometer is not a toy. Keep out of reach of children.
▸ Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
▸ The rubber eyeshade may cause irritation when in prolonged contact with the
Net weight
skin. If this happens, consult your doctor.
▸ Do not touch the lenses with your fingers.
0,140kg
5. supplied items
0,140kg
After unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
1
6. Before the first use
Remove the protective film ( if present ) from the prism surface [ 2 ] and check that
the rubber eye-cup [ 4 ] is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
4
2
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
▸ Every language version includes a non-authoritative translation.
The original German document is the definitive version.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Adjustment tool
▸ Cleaning cloth
▸ Calibration liquid (Distilled water)
3
4
5
6

Advertisement

loading
Need help?

Need help?

Do you have a question about the ORA 1UA and is the answer not in the manual?

Questions and answers

Summary of Contents for KERN ORA 1UA

  • Page 1: General Information

    The manufacturer shall not be liable for any damages caused ORA 4 UB UREA AdBlue Kombi by improper use. mit Antifrost KERN ORA 1 UA/UB UREA AdBlue Basic ORA 4 UA/UB UREA AdBlue Combi 3.2 Warranty Version 1.0 12/2014...
  • Page 2: Cleaning And Maintenance

    Calibration value ORA 1UA/1UB: 0 % urea your dealer. The device housing may only be opened by trained service technicians Calibration value ORA 4UA/4UB: 0 °C EG / PG / CW...

This manual is also suitable for:

Ora 1ubOra 4uaOra 4ub