Star Manufacturing International 8I-802H-LP Installation And Operating Instructions Manual

Ultra-max gas hotplate

Advertisement

Available languages

Available languages

Quick Links

ULTRA-MAX GAS HOTPLATE
WARNING:
Improper installation,
adjustment,
alteration,
maintenance can cause property damage,
injury or death.
operating and maintenance instructions
thoroughly before installing or servicing this
equipment.
FOR YOUR SAFETY: Do not store or use
gasoline or other flammable vapors or liquids
in the vicinity of this or any other appliance.
Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Phone: (314) 781-2777
Fax: (314) 781-3636
8I-802H-LP
8I-806H-LP
service
Read the installation,
MODELS
8I-804H-LP
8I-808H-LP
WARNING: This appliance shall be installed
or
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local
gas supplier.
1
Installation
and
Operating
Instructions
2M-Z7923 Rev. -- 6/1/04

Advertisement

Table of Contents
loading

Summary of Contents for Star Manufacturing International 8I-802H-LP

  • Page 1 International Inc. Operating 10 Sunnen Drive St. Louis, MO 63143 Instructions Phone: (314) 781-2777 Fax: (314) 781-3636 2M-Z7923 Rev. -- 6/1/04 ULTRA-MAX GAS HOTPLATE MODELS 8I-802H-LP 8I-804H-LP 8I-806H-LP 8I-808H-LP WARNING: Improper installation, WARNING: This appliance shall be installed adjustment, alteration, service...
  • Page 2: Specifications

    SPECIFICATIONS 8I-802H-LP Type: Manual Control, 2-Burner 2 Controls, 52,000 BTUH Total Propane Gas (30,000 BTUH Nat/26,000 BTUH LP per burner) Approximate Weight: Installed - 70 Lb s (31.7 kg), shipping - 120 Lbs (54.4 kg) Dimensions: 12" - Width, 30 5/8" - Depth, 14 7/8" - Height (30.5 cm - Width, 77.8 cm - Depth, 37.8 cm - Height)
  • Page 3: Safety Symbol

    SAFETY SYMBOL This symbol is intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA NOTICE CAUTION When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with either ANSI Z21.69 or CAN/CGA- This equipment is designed and sold for commercial 6.16 and a quick-disconnect device complying with use only by personnel trained and experienced in its either ANSI Z21.41 or CAN1-6.9.
  • Page 5: Leveling Unit

    LEVELING UNIT CAUTION This hotplate is supplied with 4 feet or floor stand legs which must be screwed into the body. Unit must be DO NOT INSTALL WITHOUT ATTACHING level. Level unit by adjusting the (4) feet which have an FEET OR SUPPLIED STAND LEGS AND SHELF adjustment of 1-3/4"...
  • Page 6 GAS PIPING 4. Set manifold pressure to (5) inch water column. A Gas piping shall be of such size and so installed as to 1/8" pipe plug on the burner manifold can be provide a supply of gas sufficient to meet the full gas removed for attaching a pressure gauge.
  • Page 7 BURNER IGNITION AND ADJUSTMENT COMPLETE SHUTDOWN INSTRUCTIONS 1. To ignite burners turn burner valve knob counter Turn the burner valve knobs to the OFF position to clockwise to "ON"position. turn burners off and close manual valve gas shutoff. 2. Slowly decrease openings of air shutters to give a soft blue flame having luminous tips, then slowly CLEANING increase openings to a point where the yellow tips...
  • Page 8 Visit our Website at: www.star-mfg.com E-mail: service@star-mfg.com For Fax-On-Demand Literature: (800) 807-9814 THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit.
  • Page 10: Parts List

    PARTS LIST 6/1/04 Rev. -- EFFECTIVE 8I-802H-LP, 804H-LP, 806H-LP, 808H-LP Ultra-Max LP Gas Hotplates MODEL Number Part Description and Model Designation Number Number Unit 2F-Z0637 2/4/6/8 GRATE 802 / 804 / 806 / 808 2F-Z5473 2/4/6/8 BURNER SET 802 / 804 / 806 / 808...
  • Page 11 IGNITION DU BRÛLEUR ET AJUSTEMENT INSTRUCTIONS FERMETURE COMPLETES 1. Pour mettre à feu les brûleurs tournent la molette de valve de brûleur dans le sens contraire des aiguilles Pour éteindre les brûleurs, tourner les boutons des brûleurs d’une montre à la position de "ON." sur la position de fermeture.
  • Page 12 TUYAUTERIE À GAZ 4. Régler la pression d’admission sur (5) pouces de La taille de la tuyauterie à gaz et la façon dont elle est installée colonne d’eau. On peut enlever un bouchon de tuyau doivent être telles qu’elle fournisse une alimentation suffisante de 1/8 po.
  • Page 13 ÉQUILIBRAGE DE L’APPAREIL ATTENTION Ce hotplate est assuré avec 4 pieds ou jambes de stand de plancher qui doivent être vissés dans le corps. L'unité N’INSTALLEZ PAS SANS ATTACHER ES PIEDS doit être niveau. Équilibrer l’appareil en ajustant les (4) OU DES JAMBES ET L'ETAGERE FOURNIES DE pieds qui ont un réglage de 1-3/4 po., en vue d’un STAND.
  • Page 14 DONNÉES GÉNÉRALES D’INSTALLATION NOTIFICATION ATTENTION Quand cet appareil est installé avec des roulettes, il doit être installé avec les roulettes fournies, un connecteur étant conforme à la norme ANSI Z21.69 ou au CAN/ Cet équipement n’est conçu et vendu que pour l’utilisation CGA-6.16 et à...
  • Page 15: Entretien Et Réparations

    SYMBOLE DE SÛRETÉ Ce symbole est prévu pour alerter l’utilisateur à la présence des instructions importantes de fonctionnement et d’entretien du manuel accompagnant l’appareil. MAINTENEZ CE MANUEL POUR LA FUTURE RÉFÉRENCE NOTIFICATION Employer n’importe quelle partie autre que les pièces fournies par usine véritable de Star soulage le fabricant de toute la responsabilité.
  • Page 16 St. Louis, MO 63143 Phone: (314) 781-2777 Fax: (314) 781-3636 2M-Z7923 Rev. -- 6/1/04 HOTPLATE DE GAZ ULTRA-MAX MODELES 8I-802H-LP 8I-804H-LP 8I-806H-LP 8I-808H-LP AVERTISSEMENT: L’installation inexacte, le AVERTISSEMENT: Cet appareil sera installé réglage, le changement, le service ou l’entretien selon des règlements actuels et utilisé...

This manual is also suitable for:

8i-804h-lp8i-806h-lp8i-808h-lp

Table of Contents