This product has been designed and manufactured for the sole intended use of controlling EasyHeat ILH (interior pipe heating) heating
cable sets. Improper installation, use, operation and or maintenance of these cables can cause fire and/or result in electrical shock.

Warning

1. If after carefully reading these instructions you still have
questions regarding installation or operation of this product,
call the numbers listed below for assistance.
2. The SL-2G contains an integral ground fault circuit interrupter
(GFCI). If the GFCI trips and cannot be reset, a fault exists in
the ILH heating cable set. Do not attempt to bypass the
GFCI. Bypassing the GFCI will result in the risk of fire or
electrical shock.
3. The SL-2G contains an integral temperature sensing bulb.
The sensing wire must not be kinked or compressed during
installation. When used with the ILH product, the sensing wire
must be secured to piping with tape, and not with cable ties
or pipe clamps, as these will damage the sensing wire.
Sensing wire damage will result in improper control of the
heating cables and may result in frozen pipes and the risk of
fire or electrical shock.
4. All ILH cable sets must be installed in compliance with the
latest editions of the: National Electrical Code; Canadian
Electrical Code; State or Provincial Codes;
and Local Codes.
5. These instructions must be saved and made available to
owners or users of this product and transferred to future
owners. If additional copies of these instructions are required,
contact at Easy Heat at the address noted below.
6. Do not connect more than one cable set to the SL-2G
controller, the maximum cable size that can be connected
to the SL-2G is 1440Watts (12 Amps).

LIMITED WARRANTY AND LIABILITY

Easy Heat warrants that if there are any defects in material or workmanship in this product
during the first twelve (12) months after the date of its purchase, we will replace the
product with an equivalent model, not including any labor or other installation costs.
Our obligation to replace the product as described above is conditioned upon (a)
the installation of the product conforms to the specifications set forth in our installation
instructions and (b) the product not having been damaged by unrelated mechanical
or electrical activities.
Product replacement as described above shall be your sole and exclusive remedy for a
breach of this warranty. This limited warranty does not cover any service costs relating
to repair or replacement.
We shall not be liable for any incidental, special or consequential damages as a result of
any breach of this warranty or otherwise, whether or not caused by negligence. Some
states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
The warranty above is exclusive and makes no other warranties with respect to description
or quality of the product. No affirmation of fact or promise made by us, by words or
action, shall constitute a warranty. If any model or sample was shown to you, the model or
sample was used merely to illustrate the general type and quality of the goods and not to
represent that the goods would necessarily be of that type or nature. No agent, employee
or representative of ours has authority to bind us to any affirmation, representation or
warranty concerning the goods sold unless such affirmation, representation or warranty
is specifically incorporated by written agreement.
US
T. (800) 537-4732 / F. (888) 324-2440
CAN T. (800) 794-3766 / F. (800) 361-4574
©2009 EASYHEAT
Thermostat Controller Installation Instructions
Sensing Wire

Specifications

Voltage
Current
Temperature Range
CSA Certified
Any implied warranty of merchantability or fitness for particular purpose that may arise in
connection with the sale of this product shall be limited in duration to twelve (12) months
from the date of purchase. We disclaim all other implied warranties, unless we are
prohibited by law from doing so, in which case all such implied warranties shall expire at
the earliest time permitted by applicable law. Some states do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state or province to province.
To obtain a replacement under this warranty any inoperative product or component
must be returned, with proof of purchase, to Easy Heat at the addresses noted herein.
Buyer is responsible for all costs incurred in removal and re-installation of product and
must pre-pay shipment to factory or point of purchase.
In Canada
Heating Cable Warranty Dept.
99 Union Street
Elmira ON N3B 3L7
www.easyheat.com
Sensing Bulb
120 VAC
12 Amps Maximum
2° C to 25°C ± 2°C
In USA
Heating Cable Warranty Dept.
2 Connecticut South Drive
East Granby CT 06026
14066-001 Rev. 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL-2G and is the answer not in the manual?

Questions and answers

Summary of Contents for EasyHeat SL-2G

  • Page 1 General This product has been designed and manufactured for the sole intended use of controlling EasyHeat ILH (interior pipe heating) heating cable sets. Improper installation, use, operation and or maintenance of these cables can cause fire and/or result in electrical shock.
  • Page 2 The GFCI receptacle indicator light should be off. If the GFCI pipe being heated and controlled. receptacle indicator light is illuminated press the “Reset” Mount the SL-2G to a rigid support such as a wall by way of button on the receptacle, the GFCI receptacle indicator the rear mounting slots.
  • Page 3 Ce produit a été conçu et fabriqué pour être utilisé exclusivement avec l’ensemble de câbles chauffants ILH (chauffage de canalisation interne) EasyHeat. L’installation, l’utilisation, le fonctionnement ou l’entretien inappropriés de ces câbles peut être à l’origine d’un incendie ou de chocs électriques.
  • Page 4 Ce dernier doit être situé à moins de 4 pi (1,9 m) d’une prise incendie ou des chocs électriques. électrique et à moins de 8 pi (3,8 m) de la canalisation à Brancher le cordon du SL-2G dans une prise électrique. Le chauffer. voyant de la fiche du cordon s’allumera, ce qui indique Fixer le thermostat SL-2G sur une surface rigide, par exemple que le thermostat est bien alimenté.

Table of Contents