AMSEC BSL-0601A-W Operating And Installation Instructions

AMSEC BSL-0601A-W Operating And Installation Instructions

Biometric safe lock

Advertisement

Quick Links

Biometric Safe Lock
Operating and Installation
Instructions
Part #4305278
Revised 02/10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BSL-0601A-W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMSEC BSL-0601A-W

  • Page 1 Biometric Safe Lock Operating and Installation Instructions Part #4305278 Revised 02/10...
  • Page 2 Biometric Entry Pad Electronic Actuator 1. Fingerprint Reader Window 2. LCD Screen 3. Digital Pad 4. “Reset” Button...
  • Page 3 American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions ATTENTION: • For indoor use only. • Use one 9V alkaline battery. Manufacturer recommends to use Duracell™ or Energizer® Alkaline batteries. Always use an alkaline battery for high quality performance, otherwise controller might not work well.
  • Page 4: Table Of Contents

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions Contents Enroll the first fingerprint and its bound code for quick start (level 2) ....5 Enroll the second fingerprint and its bound code (level 2) .
  • Page 5: Enroll The First Fingerprint And Its Bound Code For Quick Start (Level 2)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 1. Enroll the first fingerprint and its bound code for quick start (Level 2) Install Battery: In the back of entry pad, you will find a battery case. Install a brand new 9V alkaline battery.
  • Page 6 American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 8.6V 12/11:34 12/11:34 8.6V Lock Open User Code 06 sec Verified Now the actuator is unlocked. 8.6V 12/11:34 Select Menu Press “Menu/OK”. Press “” or “” to select “Enroll New User”.
  • Page 7: Enroll Additional Fingerprint And Its Bound Code (Level 2)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 3. Enroll additional fingerprint and its bound code (Level 2) Place an enrolled administrator’s finger (ID No. 01 or 02) on the reader window and hold. After the fingerprint and its bound code are verified successfully, the LCD screen shows “Select Menu”.
  • Page 8 American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions For example: Time Delay is set 20 minutes and Time Window 10 minutes. Place an enrolled finger (e.g. ID 03) on the fingerprint reader window and hold. After successful fingerprint’s verification, enter its bound code.
  • Page 9: Set/Change Code (Level 2)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 6. Set/Change code (Level 2) Unlock with the enrolled fingerprint and its bound code that you want to set/change code (e.g. ID No. 03). The LCD will show “ID: 03 Verified” and “Lock Open 06 sec”, followed by “Select Menu”...
  • Page 10: Enable User (Level 2)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions Note: Administrators cannot be disabled. 8. Enable User (Level 2) Unlock by an administrator. When the LCD shows “Select Menu”, press “” or “” to select “Enable User”.
  • Page 11: Delete One User (Level 2)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions Note: Two more consecutive invalid codes will restart an additional 4 minute delay period. An attempt to unlock by an enrolled fingerprint will not terminate the delay period.
  • Page 12: Set Security Level

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 12. Set Security Level Unlock the entry pad by an administrator. When the LCD shows “Select Menu”, press “” or “” to select the security level you want.
  • Page 13: Set/Change The First Code For Quick Start (Level 1) (Factory Default)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions Note: For safety and security, all codes will be automatically deleted when security level is changed. ID No. 01 code will be default code 1234567890. 13. Set/Change the first code for quick start (Level 1) (Factory Default) When setting Security Level is changed Level 2 to Level 1, the default code is 1234567890.
  • Page 14: Enroll The First Fingerprint For Quick Start (Level 3)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 8.6V 12/11:34 New Code Enter a code (10 digits). 8.6V 12/11:34 Repeat Enter the same code again. 8.6V 12/11:34 ID: 02 Code Saved The second code with an ID No. 02 is enrolled successfully.
  • Page 15: Set/Change Code (Level 1 & Level 3)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 8.6V 12/11:34 Enroll Press “Menu/OK” again. New User 8.6V 12/11:34 Place Finger Place your finger (different from the first one) on the fingerprint reader window and hold. 8.6V 8.6V...
  • Page 16 American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions fingerprint reader window. The LCD shows “ID No. Verified” followed by Time Delay. For example: Time Delay is set 20 minutes and Time Window 10 minutes. After an enrolled code is verified successfully, the LCD shows: 8.6V...
  • Page 17: Disable /Enable User (Level 1)

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 20. Disable /Enable user (Level 1 & Level 3) Unlock by an administrator. After successful verification, follow the same steps in 7 (Disable user in Level 2) or 8 (Enable user in Level 2).
  • Page 18: Authorize Unlocking Doors

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions 24. Authorize Unlocking Doors Unlock by an administrator. When the LCD screen shows “Select Menu”, press “” or “” to select “Authorize Doors”. 8.6V 12/11:34 Authorize Press “Menu/OK”.
  • Page 19: System Info

    American Security Products Co Part #4305278 AMSEC Biometric Safe Lock Operating Instructions The second letter will flash. Press “” or “” to set “o”. Press “Menu/OK”. Press “Menu/OK” twice to confirm the condition of Door 3 and 4. 8.6V 12/11:34...
  • Page 20 City ___________________ State ______ Zip Code ___________ Telephone #: ___________________________________________ Email Address: _________________________________________ Website: _______________________________________________ If you would like us to send AMSEC Safe information to a friend or have any questions concerning our complete line of security products, please send your request to: AMERICAN SECURITY...

Table of Contents