Rockwell Automation TLSZR-GD2 Installation Instructions Manual
Rockwell Automation TLSZR-GD2 Installation Instructions Manual

Rockwell Automation TLSZR-GD2 Installation Instructions Manual

Guard locking switch
Hide thumbs Also See for TLSZR-GD2:

Advertisement

TLSZR/L-GD2 Guard Locking Switch Installation Instructions
Do not attempt to install this device unless the installation instructions
IMPORTANT
have been studied and understood. This installation instruction sheet is
available in some languages at www.rockwellautomation.com/literature.
Select publication language and type "TLSZR/L-GD2" in the search field.
Ne pas tenter pas d'installer ce dispositif sans avoir étudié et compris les
IMPORTANT
instructions d'installation. Cette notice d'installation est disponible dans
certaines langues sur le site www.rockwellautomation.com/literature.
Sélectionner la langue de la publication et saisir « TLSZR/L-GD2 » dans le
champ de recherche.
Versuchen Sie nicht, dieses Gerät zu installieren, bevor Sie die
WICHTIG
Installationsanleitung gelesen und verstanden haben. Diese
Installationsanleitung steht in mehreren Sprachen unter der folgenden
Adresse zur Verfügung:www.rockwellautomation.com/literature. Wählen
Sie unter "Publication Language" die entsprechende Sprache aus und
geben Sie "TLSZR/L-GD2" in das Suchfeld ein.
Non installare questo dispositivo senza prima avere letto e compreso le
IMPORTANTE
istruzioni per l'installazione. Queste istruzioni per l'installazione sono
disponibili per alcune lingue sul sito www.rockwellautomation.com/literature.
Selezionare la lingua della pubblicazione e digitare "TLSZR/L-GD2" nel campo
di ricerca.
Não instale esse dispositivo sem estudar e compreender as instruções de
IMPORTANTE
instalação. Essa folha de instruções de instalação está disponível em
algumas línguas em www.rockwellautomation.com/literature. Selecione
a língua de publicação e escreva "TLSZR/L-GD2" no campo de pesquisa.
No instale este dispositivo sin estudiar y entender las instrucciones de
IMPORTANTE
instalación. Esta hoja de instrucciones de instalación está disponible en
algunos idiomas en www.rockwellautomation.com/literature. Seleccione
el idioma de publicación e ingrese "TLSZR/L-GD2" en el campo de
búsqueda.

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation TLSZR-GD2

  • Page 1 TLSZR/L-GD2 Guard Locking Switch Installation Instructions Do not attempt to install this device unless the installation instructions IMPORTANT have been studied and understood. This installation instruction sheet is available in some languages at www.rockwellautomation.com/literature. Select publication language and type “TLSZR/L-GD2” in the search field. Ne pas tenter pas d'installer ce dispositif sans avoir étudié...
  • Page 2: Table Of Contents

    TLSZR/L-GD2 Table of Contents Installation Instructions .............................3 Technical Specifications.............................4 Dimensions [mm (in.)] ............................6 Mounting Information [mm (in.)] ........................7 Allowable Approach Directions ......................8 Clearance in Closed Position [mm (in)]....................8 Auxiliary/Manual Release [mm (in.)] ......................8 Minimum Operating Radius [mm (in.)]....................9 Manual Override Key for Power-to-Release Version................9 Connections ................................
  • Page 3: Installation Instructions

    TLSZR/L-GD2 Installation Instructions IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Target Alignment TLSZR/L-GD2 Marks Switch Target Actuator Installation must be in accordance with the following steps and stated specifications and should be carried out by competent personnel. The unit is not to be used as a mechanical stop. Guard stops and guides must be fitted.
  • Page 4: Technical Specifications

    Mission time/PTI: 20 years or 1 x 10 cycles. Certifications CE Marked for all applicable EU directives, cULus (UL 508), and TÜV. Operating Characteristics TLSZR-GD2 Power to release TLSZL-GD2 Power to lock Assured Locking Distance [mm (in.)] Maximum target distance: 13 (0.51)
  • Page 5 TLSZR/L-GD2 Environmental Enclosure Ingress Rating NEMA 3, 4X, 12, 13, IP66, IP67, IP69K Shock and Vibration IEC 68-2-27 30 g, 11 ms/IEC 68-2-6 10…55Hz Radio Frequency IEC 61000-4-3 IEC 61000-4-6 General Housing Material UL approved glass filled PBT Actuator Material Stainless Steel Target Material UL approved glass filled PBT...
  • Page 6: Dimensions [Mm (In.)]

    TLSZR/L-GD2 Dimensions [mm (in.)] 126 (4.96) 105 (4.13) 43 (1.69) 6 (0.24) 14 (0.55) (0.83) 5 (0.2) 17 (0.67) 6.5 (0.26) Target Alignment Mark Status/ M5 x 4 23.2 (0.91) Diagnostic 11.9 (0.75) (0.47) 440G-ATZAE- xxxx 31.5 (1.24) 29.3 (1.15) 52.5 (2.07) 60.5 (2.38) 67.5 (2.66)
  • Page 7: Mounting Information [Mm (In.)]

    TLSZR/L-GD2 Mounting Information [mm (in.)] 7 (0.28) 5.5 (0.22) (1.38) 6 (0.24) 86.5 (3.4) (1.57) 6 (0.24) 13 (0.51) (0.79) (0.75) 3 x M5 1.2 Nm Target (10.62 lb-in.) Actuator 5 (0.20) dia. 2 x M5 15 (0.59) 1.4 Nm (12.39 lb-in.) 1.2 Nm (10.62 lb-in.)
  • Page 8: Allowable Approach Directions

    TLSZR/L-GD2 Allowable Approach Directions The actuator and target should always be mounted as “close coupled” and can approach the switch in any of the three entry slot positions shown. Approach from the underside is not allowed. Clearance in Closed Position [mm (in)] (and Maximum Actuator Insertion Distance for Locking) 2...5 (0.08...0.20) Do not use the switch as a guard...
  • Page 9: Minimum Operating Radius [Mm (In.)]

    (10.62 lb·in) 90° The cover with manual override key is intended for use with a power-to-release version TLSZR-GD2. It provides an auxiliary release function for use when power is not available to achieve automatic/electrical interlocking. 10000302608 Ver 00 July 2012...
  • Page 10: Connections

    TLSZR/L-GD2 Connections 3 Lock Command 2 24V DC+ 8 Safety A+ 1 Aux 4 Safety B+ 8-Pin Micro (M12) 7 0V 5 Safety A 6 Safety B Color Function White Brown 24V DC+ Green Lock 8-Pin Cordset Yellow Safety B+ 889D-F8AB-* or cable version Grey...
  • Page 11: Commissioning

    TLSZR/L-GD2 Commissioning Before use, the switch must first “learn” a new RFID door target. This is not done at the factory, as there are two options: • “Multi-Time” learn: the switch can learn up to eight targets consecutively • “One-Time” learn: the switch can learn just one target, for life, non-reversible* * ”One-Time”...
  • Page 12: One-Time" Learn Process

    TLSZR/L-GD2 “One-Time” Learn Process • Proceed as the “Multi-Time” learn process above except that at the programming finalizing stage withdraw the target and actuator away from the switch until the LED turns to solid Red, then straightaway replace the target and actuator back to the switch. This action must be completed within 15s *.
  • Page 13: Wiring Diagrams

    TLSZR/L-GD2 Wiring Diagrams Troubleshooting Series Circuit Pink Grey Brown Yellow White Pink Grey Brown Yellow White Pink Grey Brown Yellow White Pink Grey Brown Yellow White Pink Grey Brown Yellow White 10000302608 Ver 00 July 2012...
  • Page 14: Unit Response Time

    TLSZR/L-GD2 Unit Response Time (Does not include relay response time) 10000302608 Ver 00 July 2012...
  • Page 15: Application Wiring Example

    TLSZR/L-GD2 Application Wiring Example 24V* * Class 2 Power Source E-Stop LOGIC TLSZR-GD2 Aux. Reset Gate Release *Set for 30 second RANGE OFF Delay (adjustable) DI = 440R-D22R2 =440R-EM4R2D TIME L1 L2 L3 External Switched Ratings Stop/Start Circuit The safety function initiated by the E-Stop meets the safety performance requirements of SIL CL3 per IEC 62061:2005 and has a Category 4 structure that can be used in systems requiring Performance Levels up to PLe per ISO13829-1:2008.
  • Page 16: Recommended Relays

    Europe/Middle East/Africa: Rockwell Automation NV, Pegasus Park, De Kleetlaan 12a, 1831 Diegem, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788 Fax: (852) 2508 1846 Copyright ©...