Summary of Contents for Ag Leader Technology DirectCommand
Page 1
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity DirectCommand Montana Parruda 4100574 Sprayer Kit Installation Instructions 2005923 Cable Installation Kit 2000901-1...
Page 2
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Important You will save time and prevent wrong installation of components by closely Ag Leader following these step-by-step instructions. If you have questions, call Notices Technology at 515-232-5363 x 1. Direction words (LEFT and RIGHT) are commonly used when describing an installation procedure.
Page 3
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit Components installation in the sections that follow. Blue Brown Seal Seal CAN Bus connectors 1.Terminator PN: 4000141 2.Dust Plug PN: 4000136 – Not all applications 3.Y Splice PN: 4000137 1. Boom Valve Relay Module 2.
Page 4
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Component and Cable Layout PN: 2005923 Rev C December 2013 Page 4 of 17...
Page 5
Secure cables with nylon wire ties. IMPORTANT: Disconnect the Display, DirectCommand components and flow meter from electrical system when welding on or jump starting equipment to prevent component damage due to power surges or excessive current.
Page 6
• (1) RAM 2461U – Display Mount PN: 4000280 • (1) RAM 238U – Diamond Base PN: 4001149 Step–by–step Important: If this DirectCommand kit is being installed on a Montana instructions for Parruda sprayer with a positive displacement pump the Main Valve Switch mounting Control Switches to the Cable PN: 4001480-12 must be installed.
Page 7
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit Assembled Pump Switch Bracket 2. Place the Display face down on a stable surface. Align one hole in the RAM Display Mount PN: 4000280, Switch Console Bracket PN: 4001657 and the assembled Pump Switch Mounting Bracket.
Page 8
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Display with RAM mount, Switch Console and Main Valve Switch brackets 5. Align the two threaded holes in the Switch Console PN: 4000434 with the two holes in the Switch Bracket start two Phillips head screws with lock washers and tighten the screws securely.
Page 9
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit to the connector on the back of the InSight or EDGE Display, or the connector labeled MAIN on the back of the Ag Leader INTEGRA Display. 8. Route the Display Cable and the 10 Boom Switch Console Cable down to where the Cab Box will mount.
Page 10
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Boom Valve Relay Module mounting hole layout 2. Follow the layout for the mounting holes to be drilled in the Cab Box PN: 4000598. If mounting one module, mount it in the solid end of the Cab Box. De- burr the holes and clean out the Cab Box.
Page 11
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit 7. Remove the box and cut a 1/2” (13mm) slot in the floor mat on the marked locations. 8. Use the nylon Barbed Locking Retainers PN: 2002267 to secure the Cab Box to the floor by pressing them through the holes of the Cab Box and into the rubber floor mat underneath.
Page 12
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Installing the Parts required for procedure: Power Cable DirectCommand From the Kit: • (1) Montana Power Cable 10 ft.------------------ PN: 4001476-10 • (1) Cable Install Kit----------------------------------- PN: 2000901-1 Step-by-Step 1. Open the access panel on the catwalk floor leading to the batteries.
Page 13
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit 3. Remove the 2-pin Weather Pack Dust Plug from the Montana Power Cable. Connect the 2-pin Weather Pack receptacle on the Main Valve Switch Cable to the 2-pin Weather Pack plug on the Montana Power Cable.
Page 14
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit Installing the Parts required for procedure: DirectCommand From the Kit: Rate Control • (1) Deutsch Dust Receptacle 8-pin--------- PN: 2002975-8C Cables • (1) Deutsch Dust Receptacle 12-pin------- PN: 2002975-12C • (1) Boom Valve Relay Module Cable------...
Page 15
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit Dust Plug from the Montana Cab Cable. Connect the black 2-pin Deutsch plug on the Main Valve Switch Cable, to the black 2-pin Deutsch receptacle on the Montana Cab Cable. 11. Connect black 12-pin Deutsch plug of the Montana Cab cable to the black 12-pin Deutsch receptacle marked AUXILIARY on the Liquid Product Control Module.
Page 16
Ag Leader Technology DirectCommand Installation Montana Parruda Sprayer Kit 3. Route the boom valve and flow control leads of the Montana Flow Control Cable towards the components at the rear of the sprayer. 4. Route the control cables avoiding pinch points, sharp edges and allowing extra slack where needed.
Page 17
DirectCommand Ag Leader Technology Installation Montana Parruda Sprayer Kit NOTE: The Montana flow meter signal output and the Display Ag Leader requirements are both in pulses per unit of product applied. NOTE: The Display boom widths can be programmed in feet or meters.
Need help?
Do you have a question about the DirectCommand and is the answer not in the manual?
Questions and answers