Advertisement

Quick Links

Manual No. TA3001
Rev. 4 April 2015
oPerAtinG mAnUAl
moDelS:
tA-3
tA-3eA
Air SyStemS internAtionAl, inc.
829 Juniper Crescent, Chesapeake, Va, 23320
Telephone (757) 424-3967
Toll Free 1-800-866-8100
Fax No. (757) 424-5348
http://www.airsystems.com
e-mail: sales@airsystems.com

Advertisement

Table of Contents
loading

Summary of Contents for AIR SYSTEMS TA-3

  • Page 1 Manual No. TA3001 Rev. 4 April 2015 oPerAtinG mAnUAl moDelS: tA-3 tA-3eA Air SyStemS internAtionAl, inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.com e-mail: sales@airsystems.com...
  • Page 2 Always run, store, or ship the compressor in the horizontal position. Never stand the compressor upright as oil will drain from the sump and cause damage to the compressor. Check compressor oil level before each usage. If oil is low, add only Air Systems approved oil. Order P/N HP-268 USDA synthetic lubricant. Do not overfill!
  • Page 3 Set-UP/oPerAtion moDel: tA-3eA RESPIRATOR HOSE GRADE-D FILTRATION 1/2” I.D. BREATHING AIR HOSE CONNECTED TO PRIMARY AIR INLET 2/8” I.D. BREATHING AIR HOSE CONNECTED TO BACK-UP AIR INLET 115 VAC POWER CORD PRESSURE REGULATOR BACK-UP AIR CYLINDER SteP 1) Connect compressor to the primary air inlet on the Grade-D filtration unit using a 1/2” I.D. hose. SteP 2) Connect back-up air regulator to back-up air inlet on the Grade D filtration unit using a 3/8”...
  • Page 4: Oil Change Procedure

    When oil is finished draining, reinstall the drain plug and gasket. SteP 5) Fill compressor with factory approved oil. Use Air Systems part no. HP-268 (approximately .8 liters). Oil should reach the bottom threads of the filler plug/dipstick or just to the top of the sight glass. DO NOT OVERFILL! SteP 6) Reinstall the filler plug/dipstick and gasket.
  • Page 5 rePlAcement oF Air intAKe Filter AIR INTAKE FILTER PLASTIC COWL SEPARATOR CASING RETAINING CLIP SteP 1) Remove the outlet fitting from the compressor. SteP 2) Remove the black plastic cowl from the air end by pulling firmly. SteP 3) Remove the foam air filter and clean or replace. If filter is in good condition it can be cleaned with a mild detergent and water.
  • Page 6: Maintenance Schedule

    Air Systems’ manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for one year from the date of purchase. Any part which is determined by Air Systems to be defective in mate- rial or workmanship will be, as the exclusive remedy, repaired or replaced at Air Systems’...
  • Page 7: Replacement Parts

    rePlAcement PArtS ITEM # DESCRIPTION PART # OUTLET FITTING QDH5SL8M 125 PSI RELIEF VALVE VR4125BR ON/OFF SWITCH ELSW021 10” PNEUMATIC TIRE HDWR108 POWER CORD ELCB008 BACK-UP AIR CONNECTION QDH3SL4MDC CYLINDER PRESSURE GAUGE GA2075KB REGULATOR REG004 CGA-347 STEM HPBR049 CGA-347 NUT HPBR050 150 PSI RELIEF VALVE VR4150BR...
  • Page 8 Air SyStemS internAtionAl, inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.com e-mail: sales@airsystems.com Printed in the U.S.A. ©Copyright Air Systems International, Inc. 2015 All Rights Reserved...

This manual is also suitable for:

Ta-3ea