WaterFurnace SPECTRA SX Series Installation Manual

WaterFurnace SPECTRA SX Series Installation Manual

3/4 through 6 ton commercial and residential geothermal system

Advertisement

Installation
3/4 through 6 ton Commercial
Guide
and Residential Geothermal
System Installation Instructions
Contents
Model
Nomenclature
Safety
pressure and electrical components. Only trained and qualified service personnel should install,
Considerations
repair or service air conditioning equipment.
and replacing filters. All other operations should be performed by trained service personnel. When
working on air conditioning equipment, observe precautions in the literature, tags and labels
attached to the unit and other safety precautions that may apply.
operations. Have fire extinguisher available for all brazing operations.
main power switches to indoor unit. Turn off accessory heater power switch if applicable.
Electrical shock could cause personal injury.
Moving and
units may be moved and stored per the information on the carton, "Do not stack more than 3 units
Storage
in total height." Vertical units are not to be moved, but may be stored one upon another at a
maximum height of 2 units. When the equipment is received, all items should be carefully checked
against the bill of lading to be sure all crates and cartons have been received. Examine units for
shipping damage, removing the units from the cartons if necessary. Units in question should also
be internally inspected. If any damage is noted, the carrier should make the proper notation on the
delivery receipt, acknowledging the damage.
SXV
036 C
Model Type
SXV = Vertical Unit
SXH = Horizontal Unit
Unit Size
036 = 36,000 BTUH Nominal cooling
at 85°F entering water
Design Vintage
B = Commercial Microprocessor Unit Controls
C = ElectroMechanical Unit Controls
Electrical Characteristics
0 = 208-230/60/1 Commercial
1 = 208-230/60/1 Residential
2 = 265-277/60/1 Commercial
3 = 208-230/60/3 Commercial
4 = 460-480/60/3 Commercial
5 = 575-600/60/3 Commercial
Installation and servicing of air conditioning equipment can be hazardous due to system
Untrained personnel can perform basic maintenance functions of cleaning coils and cleaning
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing
WARNING: Before performing service or maintenance operations on system, turn off
Move units in the normal "up" orientation as indicated by the arrows on each carton. Horizontal
SX Series
1
0
0
C
L
T
X
Non-Standard Options
Discharge Air Options
T = T op (Vertical)
E = End (Horizontal)
S = Side (Horizontal)
Return Air Options
L = Left return
R = Right return
Coax Options
C = Copper
N = Cupronickel
Cabinet
0 = Painted Steel Cabinet
1 =Galvanized Steel Cabinet
Hot Water Options
0 = None
1 = Hot Water Generation W/Pump (Residential)
2 = Hot Water Generation Without/Pump (Commercial)
P/N 96P537A01 rev. 4/99

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPECTRA SX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for WaterFurnace SPECTRA SX Series

  • Page 1: Table Of Contents

    P/N 96P537A01 rev. 4/99 SX Series Installation 3/4 through 6 ton Commercial Guide and Residential Geothermal System Installation Instructions Table of Model Nomenclature 1 Initial Desuperheater Start Up 11 Safety Considerations 1 Electrical Connections 11-12 Contents Moving and Storage 1 Unit Electrical Data 13 Physical Data 2 Unit Operating Pressures 13...
  • Page 2: Physical Data

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Physical MODEL SX010 SX013 SX016 SX019 SX024 SX030 SX036 SX042 SX048 SX058 SX068 Fan Wheel 6 X 8 6 X 8 9 X 7 9 X 7 9 X 7 9 X 7 9 X 7 10 X 10 10 X 10 11 X 10...
  • Page 3 SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Vibrator Isolator 3/8" Threaded Rod Washer (by others) Compressor Air Handler Section Section Hex Nuts (by others) Bolt and Lockwasher MODEL MODEL SXH010-013 24.75 42.5 22.5 SXH016-019 24.75 51.5 22.5 SXH022-034 24.75 61.5 22.5 SXH042-048 27.75 70.5...
  • Page 4 SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE For vertical bottom flow units, cut the air discharge floor opening at least 1/2" larger than unit air outlet. Protect opening edges in combustible flooring with sheet metal overwrap. Discharge air only into a suitable supply duct system and do not locate registers or open- ings directly under unit air outlet.
  • Page 5: Boiler/Cooling Tower Closed Loop Systems

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Never use flexible hoses smaller than 1" inside diameter on the unit and limit hose length to 10 ft. per connection. Check carefully for water leaks. Water Quality The unit may be ordered with either a copper or a cupronickel coaxial heat exchanger. Copper is adequate for closed loop and open loop ground water systems which are not high in mineral content.
  • Page 6: General Piping

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Figure 5- Closed Loop Cooler/Boiler System 3/8” Electric heat Threaded rods assembly (6) on AT040-046 (optional) Drain per Flexible Duct Figure 2 On air Collar coil, side or end Drain per Figure 2 To Thermostat Insulate supply To Line plenum and use at...
  • Page 7: Ground Source Closed Loop Systems

    Once piping is completed between the unit, flow center and the ground loop (Figure 7 Source Closed on page 8), final purging and charging of the loop is needed. A WaterFurnace flush cart (at Loop Systems least a 1.5 hp pump) is needed to achieve adequate flow velocity in the loop to purge air and dirt particles from the loop itself.
  • Page 8: Open Loop Ground Water Systems

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Figure 7- Closed Loop: Ground Source Application ® LOOP GEOLINK Auxiliary Heat Unit Supply Polyethylene with Supply ® Armaflex Flexible Duct Collar ® GEOLINK Flow Centre* Auxiliary Heater Knockout Unit Desuperheater Power Connections * For complete Disconnects Geolink Flow (If Applicable)
  • Page 9: Desuperheater Connection

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Figure 8 - Open System: Ground Water Application Unit Supply Aux. Heat Supply Flexible Duct Collar Rubber Bladder Expansion Tank Auxiliary Heater Knockout Desuperheater Connections Water Out Drain Disconnects Water In (If Applicable) Unit Shut Off Power Valves...
  • Page 10 SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Run interconnection copper tubing (1/2” Figure 9 - Water Heater Connection Kit nominal). The recommended maximum distance is 50 ft. between the unit and water heater (see Figures 10 and 11). To prevent air entrapment in the system, install a vent coupling at the highest point of the interconnecting line.
  • Page 11: Initial Desuperheater Start Up

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Water Tank Refill Steps: Close water heater drain valve. Open cold water supply to tank. Open hot water faucet in house to bleed air from system then close when full. Depress handle on pressure relief valve to bleed any remaining air from tank, then close.
  • Page 12 SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE 208 Volt Operation All 208-230 volt units are factory wired for 230 volt operation. For 208 volt operation, the red and the blue transformer wires must be switched between terminal strip PS and contactor CC. Figure 12–...
  • Page 13: Unit Electrical Data

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Unit Electrical Compressor Residential Commercial Model Rated Voltage Motor Total Unit Min. Circuit Max. Max. HACR Total Unit Min. Circuit Max. Max. HACR Data Voltage Min./Max. Ampacity Fuse* Breaker* Ampacity Fuse Breaker SX010 208-230/60/1 197/254 23.0 10.8...
  • Page 14: Wiring Schematic

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Typical Electromechanical Wiring Schematic 208-230/60/1 97P585A01 1/25/99 C o m p r e s s o r N O T E 4 D e s u p e r H e a t e r O p t i o n N O T E 3 P S C P S C...
  • Page 15 SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Typical Commercial Wiring Schematic 208-230/60/3 and 460/60/3 C o m p r e s s o r P S C F a n N O T E 5 M o t o r B r n P S C G r n 97P577A03 12/1/98...
  • Page 16: Thermostat

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Installation Thermostat Position the thermostat backplate against the wall so that it is level and the thermostat wires protrude through the middle of the backplate. Mark the position of the backplate mounting holes and drill holes with a 3/16" bit. Install supplied anchors and secure plate to the wall.
  • Page 17: Unit Start Up

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Unit Start Up Before Starting Unit, Check The Following: High voltage is correct and matches nameplate Fuses, breakers and wire size correct Low voltage wiring complete Piping completed and water system cleaned and flushed Air is purged from closed loop system Isolation valves are open, water control valves or loop pumps wired Condensate line open and correctly pitched...
  • Page 18: Preventive Maintenance

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Initiate a control signal to place the unit in the heating mode. Heating set point must be set above room temperature. 10) First stage heating will energize after a time delay. 11) Check the temperature of both the supply and discharge water. Refer to Table 2 on page 17.
  • Page 19: Troubleshooting

    SPECTRA COMMERCIAL AND RESIDENTIAL INSTALLATION GUIDE Condensate Drain - In areas where airborn bacteria produce a slime in the drain pan, it may be necessary to treat chemically to minimize the problem. The condensate drain can pick up lint and dirt, especially with dirty filters. Inspect twice a year to avoid the possibility of overflow.
  • Page 20 In Canada Call: 1-800-463-8108 P/N 96P537A01 4/99 WaterFurnace has a policy of continuous product research and development and reserves the right to change design and speci- fications without notice. WaterFurnace is a registered trademark and Spectra is a trademark of WaterFurnace International, Inc.