Radio Description
3.5.2
Heat Dissipation
The radio is convection cooled and designed for outdoor installation. Table 7
shows the radio output power and maximum heat dissipation. Indoor installation
in a room without adequate ventilation and cooling must be avoided.
Table 7
Unit
Radio 2217 B1
Radio 2217 B3
Radio 2217 B8
Radio 2217 B20
Radio 2217 B28A
Radio 2217 B5
Radio 2218 B39A
Radio 0208 B1
3.5.3
Vibration
This section describes the radio tolerance to vibrations. The radio operates
reliably during seismic activity as specified by test method IEC 60068-2-57 Ff.
Maximum level of Required Response
Spectrum (RRS)
Frequency range
Time history signal
The radio operates reliably during random vibration as specified by test method
IEC 60068-2-64 Fh
Random vibration, normal operation
3.5.4
Materials
This section contains information about materials.
All Ericsson products fulfill the legal and market requirements regarding the
following:
22
Radio Heat Dissipation
Material declaration
Output Power (W)
2 x 40
2 x 40
2 x 40
2 x 40
2 x 40
2 x 40
2 x 40
N/A
50 m/s
1–35 Hz
Verteq II
0.3 m
2
181/1551-LZA 701 6001-1-V1 Uen PC3 | 2016-01-13
Maximum Heat
Dissipation (kW)
0.22
0.22
0.22
0.25
0.25
0.32
0.27
0.036
2
within 2–5 Hz for DR=2%
/s
3