Schoeps M? Series User Manual

Colette modular system. microphone capsules/amplifiers

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Schoeps M? Series

  • Page 1: Table Of Contents

    Colette Modular System MK -- Microphone Capsules CMC -- Microphone Amplifiers Table of Contents page System Overview CMC -- Microphone Amplifiers Phantom Powering Technical Specifications Notes on Electromagnetic Compatibility Block Diagram MK -- Microphone Capsules Capsule Selection Attaching a Capsule Basic Characteristics of Transducers Suggested Capsules for Specific Applications 11 Pressure Transducers...
  • Page 2: System Overview

    RC KC Active Tube (special version) OSIX CI elastic suspension with Active Cable Signal: balanced unbalanced SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 3: Cmc -- Microphone Amplifiers

    Four standard models of CMC amplifier are Tubes have become a mainstay of concert offered to fit the specific type(s) of microphone SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 4 The SCHOEPS CMC 6 amplifier In the realm of film and video sound an series can work with either voltage, switching older system called ”parallel powering”...
  • Page 5: Phantom Powering

    SCHOEPS microphones ade- in which standard phantom powering will en - quately. Where doubt exists, equipment should SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 6 SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 7: Technical Specifications

    If necessary, this coupling can be capacitive. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 8: Block Diagram

    Block Diagram of the CMC 3, 5, 6 Microphone Amplifiers SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 9: Mk -- Microphone Capsules

    If you are using an Active Accessory, attach it to bass response: omni MK 3. the microphone amplifier in a similar man ner. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 10: Basic Characteristics Of Transducers

    (modern, transformerless vacuum-tube circuitry). The operating requirements and range of accessories for these amplifiers vary; for detailed information please see the main catalog or www.schoeps.de. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 11: Suggested Capsules For Specific Applications

    Film and video dialog/effects Double M/S on a boom and possibly a Hamasaki Square for increased envelopment SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 12: Pressure Transducers

    40 kHz. which the levels of direct and diffuse sound are equal in a given space. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 13: Boundary Layer Microphones

    For speech applications such as conference recording, a table top may suffice. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 14 – directional pattern largely constant throughout the frequency range Polar diagram MK 22 Suggested applications: as spot / soloist’s microphone SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 15 This ring must be kept out of the capsule threads, however. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 16 This ring must be kept out of the capsule threads, however. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 17 Intermediate switch positions are Polar diagram MK 5 ”cardioid” position mechanically possible, but are not reproducable or recommended. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 18 Frequency response curve MK 4VXS + CMC 6 – lateral pickup Polar diagram essentially identical to that of the MK 4V SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 19 – compensates for proximity effect – suggested application: speech in a loud environment Polar diagram MK 41S SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 20: Specifications For Complete Microphones

    SPL capability of any usable microphone level in practice. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 21: Care And Maintenance

    (elastic suspension) should be used, and SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 22 – though a few dB of extra hiss is preferable to the risk of hard clipping. Level meters and overload indicators don’t generally SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 23: Warranty

    This guarantee is world-wide. SCHOEPS GmbH · Spitalstr. 20 · D-76227 Karlsruhe (Durlach) · Tel: +49 721 943 20-0 · Fax: +49 721 943 2050 www.schoeps.de · mailbox@schoeps.de...
  • Page 24 Subject to change without notice. Not responsible for errors or omissions. 131203 SCHOEPS GmbH Spitalstrasse 20 D-76227 Karlsruhe (Durlach) Germany Tel: +49 721 943 20-0 Fax: +49 721 943 2050 www.schoeps.de mailbox@schoeps.de Schall...

Table of Contents