Page 1
ATC-5000NG ATC/DME Test Set Getting Started Manual Issue-4 EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry...
Page 2
Getting Started Manual PUBLISHED BY Aeroflex COPYRIGHT Aeroflex 201 7 All rights reserved. No part of this publication m ay be reproduced, stored in a retrieval system , or transm itted in any form or by any m eans, electronic , m echanical, photocopying, recording or otherwise without the prior perm ission of the publisher.
Page 3
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l This m anual contains essential inform ation relating to initial use of the Unit. Aeroflex recom m ends the operator becom e fam iliar with the Operation Manual contained on the accom panying CD -ROM.
Page 4
For continued EMC com pliance, all external cables m ust be shielded and 3 m eters or less in length. Nomenclature Statement In this m anual, ATC-5000NG, Test Set or Unit refers to the ATC-5000NG ATC/DME Test Set . Declaration of Conformity The Declaration of Conform ity Certificate included with the Unit should rem ain with the Unit.
Page 5
Category II. Safety Identification in Technical M anual The ATC-5000NG should be protected from liquids such as This m anual uses the following term s to draw attention to spills, leaks, etc. and precipitation such as rain, snow, etc.
Page 6
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Safety Symbols in M anuals and on Units Case, Cover or Panel Removal CAUTION: Refer to accom panying docum ents.
Page 7
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Case, Cover or Panel Rem oval Use of Probes Opening the Case Assem bly exposes the operator to To prevent electrical shock or dam age to equipm ent: Verify electrical hazards that m ay result in electrical shock or that all the connections between the equipm en t and a device...
Page 8
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Pow er Cords The AC Power Cord included with the Test Set , or an appropriate replacem ent, should be used to connect the Test Set to a grounded AC power supply.
Page 9
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l EM I (Electromagnetic Interference ) LES GENERATEURS DE S IGNAUX ATTENTION SIGNAL GENERATORS CA N BE A SOURCE PEUVENT CONSTITUER U NE...
Page 10
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Input Overload Toxic Hazards REFER TO PRODUCT SPE CIFICATIONS FOR SOM E OF THE COM PONEN TS USED IN MAXIMUM INPUT RATING S FOR INPUT THIS EQUIPM ENT M AY I NCLUDE RESINS...
Page 11
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Toxic Hazards (cont) BERYLLIA OXYDE DE BERYLLIUM BERYLLIA (BERYLLIUM OXIDE) IS USED IN AVERTISSEM ENT DU BERYLLIUM (OXYDE DE THE CONSTRUCTION OF SOM E OF THE...
Page 12
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Toxic Hazards (cont) OXYDE DE BERYLLIUM AVERTISSEM ENT SOYEZ PRUDENT LORS D E LA DEPOSE ET DE LA M ISE AU REBUT DE CES COM POSANTS.
Page 13
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Toxic Hazards (cont) BERYLLIUM COPPER CUPROBERYLLIUM SOM E M ECHANICAL COM P ONENTS W ITHIN AVERTISSEM ENT CERTAINS COM POSANTS THIS INSTRUM ENT ARE M ANUFACTURED...
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Static Sensitive Components Table of Contents Service Upon Receipt of Material ........ 12 Unpacking............
SERVICE UPON RECEIPT OF MATERIAL Unpacking Special -design packing m aterial inside the shipping container provides m axim um protection for the ATC-5000NG. Avoid dam aging the shipping container and packing m aterial during equipm ent unpacking. Use the following steps to unpack the T est Set:...
114114 em ail: am ericas.service@ cobham .com Refer to the ATC-5000NG Operation Manual for Optional Ite m s available for the ATC-5000NG ATC/DME Test Set . S ubject to E xpor t C ontr ol , see C over P age for detai l s.
Page 17
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l ATC-5000NG M anual, Getting Started M anual, Operation Pow er Cable (AC)
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SPECIFICATIONS (S peci fi cations ar e subj ect to change wi thout noti ce. ) ENVIRONM ENTAL / PHYSICAL AC INPUT POW ER Overall Dimensions...
The following safety precautions m ust be observed during DO NOT USE A THREE -PRONG TO TW O- installation and operation. Aeroflex assum es no liability for PRONG ADAPTER PLUG. DOING SO failure to com ply with any safety precaution outlined in this CREATES A SHOCK HAZARD BETW EEN m anual.
Rack Mount where bodily injury or death m ay result. Contact Aeroflex for inform ation on installing the ATC-5000NG in a rack . S ubject to E xpor t C ontr ol , see C over P age for detai l s.
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l EXTERNAL CLEANING This section contains routine instructions for cleaning the outside of the Test Set.
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l CONTROLS, CONNECTORS AND INDICATORS Name Description Front Panel Controls, Connectors and Color LCD Used to interact with the Test Indicators...
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l Rear Panel Connectors Refer to Num erical Reference Charts for connector cross - Name Description reference.
Page 24
(100 to 240 VAC, 50 to 60 Hz). Connects (I) or disconnects (O) Pow er Sw itch external AC power from the ATC-5000NG. S ubject to E xpor t C ontr ol , see C over P age for detai l s.
Verify the Power Switch Indicator illum inates. W ait while the Test Set com pletes the power-up sequence. The ATC-5000NG Main Menu is displayed. Pow er OFF Test Set S T E P P R OC E D U R E Press the Power Switch (Front Panel) to power OFF the Test Set.
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l TOUCH SCREEN SCREEN FEATURES AND ICONS The ATC-5000NG contains a resistive Touch Screen that is responsive to the touch of a hum an finger. Gloves can be worn when utilizing the Touch Screen or a writing instrum ent (e.g.
Page 27
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SCREEN FEATURES AND ICONS (cont) Icon Description Icon Description External equipm ent is connected to the An error has occurred.
Page 28
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l SCREEN FEATURES AND ICONS (cont) Feature Description Feature Description Local Mode - All controls on the Norm al Mode - Controls are m odified Touchscreen are enabled.
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS M ain M enu M ulti-Receiver M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
Page 30
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS (cont) Transponder M enu DM E M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
Page 31
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS (cont) UAT M enu System M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s .
Page 32
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l MENUS AND SCREENS (cont) Support M enu ( T h i s s c r e e n i s a r e p r e s e n t a t i o n o f t h e s c r e e n t h a t a p p e a r s . ) S ubject to E xpor t C ontr ol , see C over P age for detai l s.
Page 33
A T C - 5 0 0 0 N G G e t t i n g S t a r t e d M a n u a l THIS PAGE INTENTIONALLY LEFT BLANK. S ubject to E xpor t C ontr ol , see C over P age for detai l s.
Page 34
We reserve the right to make design changes without notice. Go to http://ats.aeroflex.com/contact/sales-distribution for Sales and Service contact information. EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774.
Need help?
Do you have a question about the ATC-5000NG and is the answer not in the manual?
Questions and answers