Table of Contents

Advertisement

6. Feed the 2 wire Romex through the handy box. Using the included wire nuts, tie the black wires
together. Tie the white neutral wires together. Tie your bare copper wire and green ground wires
together.
7.
Carefully reinstall the handy box cover.
Figure 3.1B
Whole House Fan
Whole House Fan
3.2 Two Speed Wiring (for ES-4700)
1. For this installation, you will need (3) 2 wire Romex, an 8 Hour Timer, and a HIGH-LOW-OFF Switch.
2. Using your first 2 wire Romex, tape the white common wire because we are going to use it for low speed.
Attach the white wire to the top gold screw on the right of the switch. Then, attach the black wire to the
bottom gold screw. (see Figure 3.2A)
3. With a piece of bare copper wire, attach it to the green ground screw on the switch.
4. Using the second 2 wire romex that's going to your timer, use one of the supplied wire nuts to tie the
black wire to the black wire on the timer. Tie the white wire from the 2 wire Romex to the white wire on
the timer.
5. Using a wire nut, tie all bare copper wires together with the green ground wire on the timer.
6. Attach the red leg wire from the timer to the top black screw on the switch. Finish up the installation of
the timer and switch and switch cover plate.
7. Begin wiring the ES-4700 by opening up the handy box. Take off the wire nuts within the handy box.
Detach the green ground wire from the power cord. Remove the power cord. Re-attach the ground screw
and wire to the handy box. Cut your green ground wire in half and strip both sides.
(see Figure 3.2B)
8
Tie All Ground & Bare Copper Wires Together
Tie All Ground & Bare Copper Wires Together
All White Common Wires Together
All White Common Wires Together
All Black Wires Together
All Black Wires Together
14-2 Wire
14-2 Wire
QUIETCOOLSYSTEMS.COM
Switch
Switch

Advertisement