VOLTCRAFT AC Mini VC-520 Operating Instructions Manual page 49

Clamp meter
Table of Contents

Advertisement

Available languages

Available languages

Resistance, overload protection 600 V
Range
400.0 Ω
4.000 KΩ
40.00 KΩ
400.0 KΩ
4.000 MΩ
40.00 MΩ
Capacity, overload protection 600 V
Range
40.00 nF
400.0 nF
4,000 µF
40.00 µF
100.0 µF
Temperature
Range
-20.0 to +760.0 °C
Frequency, overload protection 600 V
Range
10 Hz - 10 kHz
Acoustic continuity tester
Diode test test voltage:
Diode overload protection/continuity tester: 600 V
Accuracy
±(1,3% + 8)
±(1,8% + 8)
±(2,5% + 5)
±(3,5% + 5)
Accuracy
±(4% + 30)
±(3,5% + 15)
±(4% + 20)
Accuracy
±(3% + 60)
Accuracy
±(1,5% + 5)
<100 Ω
1.5V / test voltage approx. 0.3 mA
Definition
0.1 Ω
1 Ω
10 Ω
100 Ω
1 KΩ
10 KΩ
Definition
0.01 nF
0.1 nF
1 nF
0.01 µF
0.1 µF
Definition
0.1 °C
Sensitivity
15 Vrms
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac/dc mini vc-521

Table of Contents