Download Print this page

PTAC WALL SLEEVE Installation Instructions

Advertisement

Quick Links

The wall sleeve must be installed before the air conditioner or heat pump chassis can be
When 230/208 volt units are to be installed, the power
supply may be either cord connected or permanent
wiring. Permanent wiring may be done through the hard
wire junction box, or the accessory subbase.
When 265 volt units are to be installed, the power supply
must be permanent wiring. Permanent wiring may be
done through the accessory hard wire junction box, or
the accessory subbase. An exposed cord connection
on 265 volt units is not permitted.
The subbase accessory includes leveling legs. If added
wall sleeve support is required and the subbase is not to
be used an accessory leveling leg kit may be installed.
KIT ACCESSORIES ..................................................................................................... 2
D
K
RAIN
S
UBBASE
PRE-INSTALLATION CONSIDERATIONS .................................................................. 3
O
UTDOOR
WALL SLEEVE INSTALLATION .................................................................................. 4
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during installation or repair it is possible to place yourself in a
Remember, it is your responsibility to install the product safely and to know it well enough to be able to
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual, the
Part No. A3495105
Printed in USA
PTAC W
I
NSTALLATION
set in place. Read the instructions thoroughly before proceeding.
....................................................................................................... 2
IT
, L
L
, M
EVELING
EGS
AIN
E
P
R
NCLOSURE
ANEL
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
includes all safety precautions and related items.
position which is more hazardous than when the unit is in operation.
instruct a customer in its safe use.
specific good safety practices...follow them.
precautions listed here take precedence.
S
ALL
LEEVE
I
NSTRUCTIONS
Contents
D
,
H
UCT
AND
YDRONIC
.............................................................. 3
EMOVAL
Made in USA
H
K
........................ 2
EAT
ITS
August 2005

Advertisement

loading
Need help?

Need help?

Do you have a question about the WALL SLEEVE and is the answer not in the manual?

Questions and answers

Summary of Contents for PTAC WALL SLEEVE

  • Page 1 LEEVE NSTALLATION NSTRUCTIONS The wall sleeve must be installed before the air conditioner or heat pump chassis can be set in place. Read the instructions thoroughly before proceeding. When 230/208 volt units are to be installed, the power supply may be either cord connected or permanent wiring.
  • Page 2 KIT ACCESSORIES RAIN An indoor/outdoor drain kit is available as an accessory item. When a drain kit is to be installed, do so before installing the wall sleeve in the wall. See the drain kit for actual installation instructions. UBBASE EVELING...
  • Page 3 • If installed in a concrete or masonry wall, a lintel must be provided in the wall opening for support. Do not use the wall sleeve as a lintel. See Figure 5 for a typical lintel construction. • When installed in the opening, the wall sleeve...
  • Page 4 Alternative sleeve. Fastening Method (Field Supplied) 2. Slide the wall sleeve into the wall opening. Do not dis- tort the cabinet shape to fit the wall opening; the unit Wood Screw Toggle Bolt chassis must fit snugly and uniformly into the wall...