Page 1
2G & 3G PIR / IR BEAM Detector MODEL P I R - I R B E A M...
Page 2
Our 2G/3G PIR or Beam Detector is a standalone alarm system suitable for outdoors or indoor usage. It will alert you using GSM technology by sending you a text message and/or phone call When the sensor has been triggered to your mobile or landline phones. The unit is also enclosed in a IP65 rated box which means it is perfectly weathered for outside installation and has passed testing in high temperature and below freezing conditions.
Page 3
Slide the simcard into the holder making sure that the clipped corner of the simcard lines up with the clipped corner of the simcard holder as picture above. To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the dialler is receiving by texting the command The dialler will perform a test on the signal strength.
Page 4
After inserting your simcard into the Auto-Dialer turn the unit on and wait until you see the LED is on. This will indicate that you have a mobile signal and the unit is ready for use. You will now need to send a text with the contact number Note - To avoid confusion we have colour coded the hash (#) and the equals (=) symbols.
Page 5
You can now change the alarm message for inputs 1 & 2 to your own choosing. To change the message send the text command as follows. Default message #MESS1= YOUR MESSAGE (Input 1 Detected) Input 1 #MESS2= YOUR MESSAGE (Alarm triggered) Input 2 This will change the message to “YOUR MESSAGE”...
Page 6
HOW TO USE THE 2G/3G PIR & IR BEAM The 2G/3G PIR and IR Beam Detector has two independent input’s Input 1 = Detect and Auto Reset & Input 2 = Alarm Detect —-—––––––––––––––-—–-—–––––-—–––-—–-—–––-—–- Input 1: The unit Is always armed and will trigger when the movement is detected, it will automatically reset after 20 Seconds when no movement is detected.
INPUT 2 ONLY CALL+TEXT CALL ONLY RESET To reset the unit back to factory settings you will need to send a text message #RESET# Warning this will reset all of your parameters, only send a reset command when necessary. The green ready led will flash 8x Dipswitch settings Typical Application of Product Dipswitch 1 =...
Page 8
Please make sure you supply a 9 - 24 volts DC from the battery terminals via a 2 amp fuse (for alarm panel installations) Note: Input 3 Not used INPUTS 1 : A u t o D e t e c t 2 : A l a r m D e t e c t 3 : n o t u s e d Relay Ou tput...
Need help?
Do you have a question about the IR BEAM and is the answer not in the manual?
Questions and answers