Gigahertz NFA 1000 Operating Manual

3d low frequency analyzer with data logger
Hide thumbs Also See for NFA 1000:

Advertisement

Quick Links

NFA 1000
NFA 400
3D Low Frequency
Analyzer
with Data Logger
Operating Manual
Version 7.9
About this Manual
e only significant difference between the NFA 1000 and the NFA
400 in this manual is the fact that the NFA 1000 allows a three-di-
mensional potentialfree measurement of the E-field, while the NFA
400 can only be used for one-dimensional potentialfree measure-
ments of the E-field. This distinction is specified in detail in the rel-
evant chapters
NFAsoft
Analysis and
Configuration
Software
Made in Germany

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NFA 1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gigahertz NFA 1000

  • Page 1 About this Manual e only significant difference between the NFA 1000 and the NFA 400 in this manual is the fact that the NFA 1000 allows a three-di- mensional potentialfree measurement of the E-field, while the NFA 400 can only be used for one-dimensional potentialfree measure- ments of the E-field.
  • Page 2: Table Of Contents

    Technical data and specifications are to be found on our website www.gigahertz-solutions.com. Contents Quick Start Guide NFA 1000 Front Cover LEDs / Display / Audio Signals Switches / Push-Buttons / Connectors How to Measure and Data-Log Power Supply „NFAsoft“...
  • Page 3: Quick Start Guide

    To allow a simplified freehand measurement, the meter is pre-adjusted with a 16 Hz high pass filter for the magnetic field and a 50 Hz high pass filter for the electric field (see page 23 for measurements from 5 Hz onwards). - 1 - © Gigahertz Solutions GmbH December 2018...
  • Page 4: Nfa 1000

    Made in Germany 2 Front Cover NFA 1000 and NFA 400 Analogous front cover for NFA 1000 and NFA 400 NFA 1000 AC/DC 3D-NF-Analyser 5 Hz - 1000 kHz Mode Auto Band Freq. „Ey“ NFA 400: Signal Power tRMS TCO-Band...
  • Page 5: Leds / Display / Audio Signals

    With “Freq.” the actual mains frequency can be determined ex- actly. The LED’s for 16.7 Hz, mains frequency and its harmonics up to 2 kHz have a suitable lock-in range to cover mains fluctuations. - 3 - © Gigahertz Solutions GmbH December 2018...
  • Page 6 16.7 Hz for magnetic fields and to 50 Hz for electric fields. Electric fields of the - 4 - December 2018 © Gigahertz Solutions GmbH...
  • Page 7 To make it more ergonomic for the user, frequencies below the nominal display resolution (that is < 0.1 V/m or < 1 nT) are not indicated by an LED-signal but will still be recorded down to the noise level. Hysteresis: 9/12% resp. 45/50%. - 5 - © Gigahertz Solutions GmbH December 2018...
  • Page 8: Switches / Push-Buttons / Connectors

    XYZ = Axis indication Here, the NFA 1000 will show either the magnetic or the electric field in its three individual components depending on the field type from which the switch was set to “XYZ”, whereas the NFA 400 will only show the individual components of the magnetic field.
  • Page 9 1.5 m to the object of measurement. For E-field measurements against earth potential, please plug in the grounding cable and switch to “M3D” (automatic adjustment) on the NFA 1000 switch to “Ey” on the NFA 400. 4.3 Sockets for Inputs and Grounding...
  • Page 10 Socket for the TCO-conformed probe at the front end of the meter This is for the TCO-conformed probe available as an optional ac- cessory from Gigahertz Solutions. No data logging! Mode = Selection of Measurement Mode Selects all measurement and display options of...
  • Page 11 Tolerances are much higher than using the tRMS analysis. It cannot be used with the floating potential E-field measurement for the time being. - 9 - © Gigahertz Solutions GmbH December 2018...
  • Page 12 12 V external battery (motorcycle gel battery (no lithium! ), we have configurated a universal connecting cable for you (“BAK”)”. extensive testing with classical power banks and lithium polymer batteries for flight models showed disappointing results. - 10 - December 2018 © Gigahertz Solutions GmbH...
  • Page 13 NFAsoft to the corresponding recording times in the graphic. In order to be correctly allocated by NFAsoft, the WAV files need to be saved in the same folder as the LOG file. - 11 - © Gigahertz Solutions GmbH December 2018...
  • Page 14: How To Measure And Data-Log

    These recordings can be annotated by real-time audio recordings which will be assigned automatically to the respective measure- ment for replay. The chapters 5.2 and 5.3 are only relevant for the NFA 1000. Guided 9 Point Measurement of Sleeping Areas For alternating electric fields, the guidelines issued by the VDB e.V., Germany, require a...
  • Page 15 “hit“ the measurement point, if you use a holder then withdraw quickly to a minimum distance of 1.5 m and keep still there in order to avoid movement-in- duced "pseudo-fields”. - 13 - © Gigahertz Solutions GmbH December 2018...
  • Page 16 SD-card to “lock” or “write protect” and reinsert it. Note: The data will still be recorded! IMPORTANT: Don't forget to “unlock” the SD memory card finishing a “locked” long term recording! - 14 - December 2018 © Gigahertz Solutions GmbH...
  • Page 17: Power Supply

    Please note that Li-Ion batteries, even when treated with care, will lose some of their original capacity within one or two years and their typical life expectancy is 250-500 complete charge cycles. In this case please always replace both bat- teries. - 15 - © Gigahertz Solutions GmbH December 2018...
  • Page 18 Evaluating the logged data on the PC will potentially show difference that can be corrected, if necessary. extensive testing with classical power banks and lithium polymer batteries for flight models showed disappointing results. - 16 - December 2018 © Gigahertz Solutions GmbH...
  • Page 19: Nfasoft

    (the consecutive numbering is independent from the file type)  LOG00001.TXT log file (long time recording)  LOG00002.9PM 9-Point-Measurement (sleeping area)  LOG00003.6PM 6-Point-Measurement (workplace)  REC00004.WAV audio file (recorded note). - 17 - © Gigahertz Solutions GmbH December 2018...
  • Page 20 Navigation within the Plotted Data Within the plotted data you can easily navigate using a mouse and its scroll wheel. Move the mouse pointer into the data plot. The scale of the x-axis will be - 18 - December 2018 © Gigahertz Solutions GmbH...
  • Page 21 The 95th percentile is calculated heuristically. If the possible deviation exceeds 10%, it will be noted in parenthesis after the figure in absolute terms. - 19 - © Gigahertz Solutions GmbH December 2018...
  • Page 22  Manual – The y-axis scaling can be manually controlled in this mode. Allows for and will assist in analyzing small values (e.g. - 20 - December 2018 © Gigahertz Solutions GmbH...
  • Page 23 When clicking the „ok“ button, the selected criteria and the set value will be transferred into the statistical values of the channel. When re-accessing the menu option “Set edge criteria”, the pre- set values will again be displayed (under construction). - 21 - © Gigahertz Solutions GmbH December 2018...
  • Page 24 “.9PM”. The illustration is frequency specific. Please note that the readings of the channels X, Y and Z as well as “All CH4” are dependent on the position of the instrument and that the - 22 - December 2018 © Gigahertz Solutions GmbH...
  • Page 25 “save as pre-setting for NFAsoft”. All pre-set- tings are stored in the file “NFAsoft.ini” and are available for NFA- soft provided that this file is in the same folder. - 23 - © Gigahertz Solutions GmbH December 2018...
  • Page 26: Firmware-Update

    “Rec.”-key at the same time while switching on the meter. Please differentiate: With „NFAsoft“ the firmware can be configured and the user settings stored in the file „CONFIG.NFA“. This has nothing to do with the firm- ware itself. - 24 - December 2018 © Gigahertz Solutions GmbH...
  • Page 27 Do not switch off the meter during the update process! Don’t forget to unlock the SD-card afterwards! Recalibration of the battery capacity display (please see next page: Chapter 9) - 25 - © Gigahertz Solutions GmbH December 2018...
  • Page 28: What If

    The meter has four measurement channels which always work simultaneously. Three of them are needed for the 3D measurement, the fourth channel can be used for any other required measurement task. - 26 - December 2018 © Gigahertz Solutions GmbH...
  • Page 29 NFA. NFAsoft can write this file, but not read it. Therefore you cannot use NFAsoft to check the configuration of the NFA, but only to instal new configu- rations. - 27 - © Gigahertz Solutions GmbH December 2018...
  • Page 30 These pseudo-readings can be deleted from the graph by opening the 9PM-file with a text editor and replacing the odd value by “0.0”. - 28 - December 2018 © Gigahertz Solutions GmbH...
  • Page 31 NFAsoft. The audio files (.wav) will only be displayed in the diagram if they are stored in the same folder as the LOG-file and if they are not re- named. - 29 - © Gigahertz Solutions GmbH December 2018...
  • Page 32 Made in Germany Manufacturer Gigahertz Solutions GmbH Im Kessel 2 90579 Langenzenn Germany Tel : +49 (9101) 9093-0 Fax : +49 (9101) 9093-23 www.gigahertz-solutions.com Your local partner...

This manual is also suitable for:

Nfa 400