Download Print this page

A2Z Ozone Systems Aquatic 2 Installation & Operation Manual

Spa ozone generator
Hide thumbs Also See for Aquatic 2:

Advertisement

A2Z Ozone, Inc.
PRODUCT
MANUAL
INSTALLATION & OPERATION MANUAL
CE
www.a2zozone.com
Rev. 02142018

Advertisement

loading

Summary of Contents for A2Z Ozone Systems Aquatic 2

  • Page 1 A2Z Ozone, Inc. PRODUCT MANUAL INSTALLATION & OPERATION MANUAL www.a2zozone.com Rev. 02142018...
  • Page 2: Table Of Contents

    CONTENTS Page • Important Safety Instructions ..• Specifications ........• Installation Instructions ....• Troubleshooting ......... • Warranty ...........
  • Page 3: Important Safety Instructions

    Follow all applicable electrical codes. Be sure the electrical power is shut OFF at the main circuit breaker before installing the Aquatic 2. If the Aquatic 2 electrical connection will be attached to the spa controls, be sure the spa controls are protected by Ground Fault Circuit Interrupter (GFCI).
  • Page 4: Specifications

    SPECIFICATIONS Model Aquatic 2 Electric 85-250 VAC 50/60 Hz Power Ozone Output 300 mg/hour Size 3.6 x 2.5 x 5.7 inches 92 x 62 x 146 mm Weight 0.74 lbs, 330 grams Connection AMP model Cable 5.5 feet Check Valve...
  • Page 5: Installation Instructions

    The injector ports are vacuum sources used to pull the ozone gas out of the Aquatic 2 and into the water. Please keep in mind, at no time should water come in contact with the Aquatic 2. The unit must be mounted and plumbed as described in this manual to prevent water from traveling backwards through the tubing and into the ozone generator.
  • Page 6 Do not connect the Aquatic 2 if there is no vacuum at injector suction. NOTE: If the Aquatic 2 is mounted below the water line, run the tubing to a point above the water line and back down to the vacuum source. Secure the tubing in this position, slide the hose ties on each end into the tubing and secure all tubing connections with the hose ties.
  • Page 7 Figure 1...
  • Page 8 At this point, a vacuum should be created and the suction can be felt on the tube. The Aquatic 2 should be on ONLY when the pump is ON. If your spa did not have an ozonator, then connect the ozone electric wire to the pump wires.
  • Page 9 Test the GFCI breaker protecting the spa for proper operation. Disconnect power to the spa. Connect the Aquatic 2 cord to the mating connector(s) on the spa control box as described in the spa’s installation manual and Figure 2. Where possible, route the power cord away from other electrical lines. Do NOT run the power cord parallel to any low voltage signal wires.
  • Page 10 Once properly installed, the ozone generator requires no further maintenance. It will operate automatically with the spa system. To ensure the highest degree of sanitation at all times, refer to the chart below. Renew your Aquatic 2 as needed with a renewal kit. Daily Use Average Unit Life...
  • Page 11: Troubleshooting

    Aquatic 2. Keep in mind, the Hartford Loop should also be hanging above water level. SYMPTOM: The red LED light is not lit. This means there is no power to the Aquatic 2. Check the electrical connections and then the fuse.
  • Page 12: Warranty

    WARRANTY A2Z Ozone Systems Inc. - ONE YEAR LIMITED WARRANTY The limited warranty set forth below applies to products manufactured by A2Z Ozone Systems Inc. - and sold by A2Z Ozone Systems or its authorized dealers. This limited warranty is given only to the first retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products. A2Z Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven to be defective in materials or workmanship within ONE (1) year from the date of retail purchase of such products.