Web Panels with TFT Display User manual UM EN WEB PANELS...
Page 2
Web Panels with TFT Display 2014-07-01 Designation: UM EN WEB PANELS Revision: Order No.: — This user manual is valid for: Designation Order No. WP 04T 2913632 WP 06T 2913645 WP 07T/WS 2700307 WP 09T/WS 2700309 WP 10T 2700934 WP 15T...
Page 3
The receipt of technical documentation (in particular user documentation) does not consti- tute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observ- ing the applicable standards and regulations.
The user manual, in particular the safety notes, must be observed by all personnel wor- king with the device. – Observe the accident prevention rules and regulations that apply to the operating site. – Installation and operation must only be carried out by qualified and trained personnel. 8361_en_02 PHOENIX CONTACT...
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Intended Use – The device is designed for use in the industry. – The device is state-of-the art and has been built to the latest standard safety require- ments.
Unpack all parts carefully and check the contents for any visible damage in transit. Also check whether the shipment matches the specifications on your delivery note. If you notice damages in transit or discrepancies, please contact Phoenix Contact immedi- ately.
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Connecting the Device 2.3.1 Supply Voltage The supply voltage is supplied via pin strip X1. A suitable socket strip is supplied. Refer to the technical data for the permissible supply voltage of the operating device.
Fit the stripped wires - depending on the type of device - with a slip-on sleeve or a ring cable lug. Plug the slip-on sleeve on the flat tab or mount the ring cable lug with the nut to the threaded bolt. Figure 2-21 Noiseless ground / protective ground 8361_en_02 PHOENIX CONTACT...
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Switching On The operator panel is equipped with the Windows CE operating system, on which the Microbrowser runs. 2.4.1 Loading Procedure on Windows CE Operating System The operating device allows you to make changes to the configuration at start procedure with the buttons.
Page 31
Start URL below after... http://192.168.0.2/entry.html Info Page Restore Save Test Settings OS Settings... Quit Info Page Device Name: WP 04T Serial Nr.: 200907210055 MicroBrowser Ver.: 1.5.15.130 5.0.1400.3 Platform: uBCE Display: 320 x 240, 16 BPP < Test Page...
Page 32
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T The last change is undone. Settings, Save: The settings are stored. Settings, Test Settings: The following tests are possible: Buzzer on/off, backlight on/off, brightness 1/15/32. Settings, OS Settings...: The operating mode setup main is started.
Page 33
Touch Screen & Registry: Touch Screen & Registry Save Registry Home Settings Change Backlight Display Mode Properties Start SNTP Calibration Settings Figure 2-27 Touch Screen & Registry Touch Screen & Registry, Save Registry Settings: The entire registry is saved. 8361_en_02 PHOENIX CONTACT...
Page 34
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Touch Screen & Registry, Change Display Mode: Change Display Mode Current Mode Cancel LCD Saver Figure 2-28 Change Display Mode Set-up of display adjustment. LCD Saver switches the brightness to the lowest value, if no user operation occures for at least one hour.
Page 35
Device Name: MyName DHCP enabled Gate: 000.000.000.000 1. DNS: 000.000.000.000 2. DNS: 000.000.000.000 1. WINS: 000.000.000.000 2. WINS: 000.000.000.000 Figure 2-32 TCP/IP Info The following informations are displayed: – MAC address – IP address – Subnet mask address 8361_en_02 PHOENIX CONTACT...
Page 36
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T – Device name – DHCP status – Gateway address – 1. DNS address – 2. DNS address – 1. WINS address – 2. WINS address Network Settings, Fix Settings, IP Address:...
Page 37
Save registry and restart device to work with new parameters Figure 2-37 DHCP You may enable DHCP service. You must save this setting when exiting of by using „Save Registry Settings“. This entry is able to be password-protected. 8361_en_02 PHOENIX CONTACT...
Page 38
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Network Settings, FTP Settings, Add new user: Add new user Enter User MyName Enter Password **** Confirm Password **** Cancel Figure 2-38 Add new user You may enter a new user name. You have to assign a password to the user name and to confirm it.
Page 39
Selection of color depth for TFT displays. This entry is able to be password-protected. Settings, Date / Time: Date / Time Current Time 15:00:00 AM Time Zone (GMT +01:00) Amsterdam,Berlin,Bern,Rome Automatically adjust clock for daylight saving Apply Figure 2-43 Date / Time 8361_en_02 PHOENIX CONTACT...
Page 40
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Set the date, time and time zone. Settings, Password: Password Current Password Enable Password Change Cancel Figure 2-44 Password The password can be activated, deactivated or redefined. When the password is activated, all password-protected dialog boxes can only be accessed if the password has been en- tered successfully.
Page 41
Network Server Login You can save login data for network printing. This enables auto-login when printing without manual input at the operating device. Enter a user name, password and domain. This entry is automatically stored in the registry. 8361_en_02 PHOENIX CONTACT...
If the display is damaged, avoid touching, swallowing or breathing in the liquids or gases which may leak out! Pixel failures, which can occur with TFT displays, are due to production and no complaint reason! The operating device is equipped with different displays depending on variant. 8361_en_02 PHOENIX CONTACT...
Interfaces of the Device Interfaces of the Device Standard Interfaces Figure 4-1 Rear view Ethernet Female Connector X5 (Ethernet) Female Connector X9, X10 (USB Host - Type A) Threaded Bolt for Protective Grounding Connector X1 (Supply Voltage) 8361_en_02 PHOENIX CONTACT...
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T 4.1.1 Ethernet (X5) A 10/100Base-T Ethernet interface is located at the operating device. 4.1.1.1 Pin Assignment Connector in the operating device: RJ45 female connector. Table 4-1 Assignment of the Ethernet interface...
This includes input devices intended for home and office use. 4.1.2.1 Cable For the specification of a suitable cable, please refer to the „Universal Serial Bus Specifi- cation Rev. 2.0“. NOTICE Use industrial-suited USB cables with a length of maximally 2.5 m (8.202 feet). 8361_en_02 PHOENIX CONTACT...
At an ambient temperature of 20 °C (68 °F), the regeneration takes approximately 20 seconds. The higher the ambient temperature, the longer the regeneration takes. 8361_en_02 PHOENIX CONTACT...
- 25 °C to + 70 °C (-13°F to + 158°F) storage, transport Relative air humidity for operation and 20 % to 85 %, no condensation storage Application area Degree of pollution 2, overvoltage category III No direct solar radiation 8361_en_02 PHOENIX CONTACT...
Page 52
WP 04T, WP 06T, WP 07T/WS, WP 09T/WS, WP 10T, WP 15T Standards and Guidelines Interference immunity DIN EN 61000-4-2 DIN EN 61000-4-3 DIN EN 61000-4-4 DIN EN 61000-4-5 DIN EN 61000-4-6 DIN EN 61000-6-2 Emitted interference DIN EN 55011 limit value class A...
Technical Data WP 04T Display Size (diagonal) in cm (inch) 8.89 (3.5) Type TFT (color) Resolution (pixels) 320 x 240 Colors 65536 Reading angle (vertical / horizontal) 150° / 130° Backlight Half-life backlighting 40,000 h Brightness in cd/m Display area (H x W) in mm (Inch) 52.5 x 70 (2.066 x 2.755)
Mounting cutout (H x W) in mm (Inch) 139 x 195 (5.7472 x 7.677) Mounting depth in mm (Inch) About 42 (1.654) Standard / Field Bus Interface: About 54 (2.126) Degree of protection Front: IP65 Rear: IP20 Total weight About 1000 g 8361_en_02 PHOENIX CONTACT...
Mounting cutout (H x W) in mm (Inch) 212 x 287 (8.346 x 11.299) Mounting depth in mm (Inch) About 55 (2.165) Standard / Field Bus Interface: About 67 (2.638) Degree of protection Front: IP65 Rear: IP20 Total weight About 1800 g 8361_en_02 PHOENIX CONTACT...
Need help?
Do you have a question about the WP 04T and is the answer not in the manual?
Questions and answers