Safety Information Preventing injury Safety Symbols Safety Symbols Safety Symbols Explaining the symbols This is the Read Instruction Manual symbol. This symbol indicates that you must read the instruction manual. Indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury.
For your safety Fire and/or explosion hazard Control Panel Power connections: DC and AC Pressure limits and power issues Specifications Hazardous voltage inside. Risk of electric shock or burn. The control panel should only be removed by authorized electrical technicians.
Sales sales@meriam.com Website www.Meriam.com Local Meriam Representatives Use this link to help you find Meriam representative on this world map: LOCATOR. Find a local Meriam representative Or, you may use this full website address to go to the same location: http://www.meriam.com/representatives-map/...
Power, Computer, and Measure. Data Panel The Data Panel displays in the PIT5000 application on the right side in all tabs. The panel displays different information including flashing red alarms and the following four buttons: Start Program, Begin Test, End Test, and Add Notes.
Page 10
RTD is an abbreviation of Resistance Temperature Detectors. Strip Chart Strip Chart is a tab in the PIT5000 application that displays a live plot of pipe pressure (Press), ambient temperature (T-Amb) and pipe temperature (T-Pipe) versus time in order to record the hydrostatic test and its duration.
Receiving, unpacking, and setting up the PIT5000 Receiving and unpacking Receiving the PIT5000 Unpacking the PIT5000 Don’t lose any of the components a small 316SS adaptor fitting Gear Kit ...
Power On button The On / Off button is behind the Plexiglas panel. Computer Windows 10, PIT5000 Application Nameplate PIT5000 serial number, Meriam address, power. Computer power For the computer. and USB cables Documentation Onsite Setup Guide and NIST pouch Certificates.
Control panel Control Panel Control Panel description Item Description Power pane Two power connections, toggle switch, LCD display Computer pane Two auxiliary USB ports Measure pane Stroke counter connection, connections for pressure and temperature. Control panel plate The control panel should only be removed by authorized electrical technicians.
Page 17
LCD unreliable. Input voltage list It reminds you of three levels: 1. The highest allowable is 15.0 V. 2. An audible alarm sounds when the battery voltage goes below 10.5 V. 3. The PIT5000 shuts off at 10.0 V.
Page 18
DC power Standard: Optional: Note: It can be used to power the PIT5000 anywhere a compatible 12 V dc car adapter is available. This can be especially useful when hydrostatic tests run longer than anticipated and the battery level gets low.
Page 20
Measure Stroke Counter Note: The PIT5000 has a digital counter that is equipped to supply power and count the strokes made by high- pressure, plunger pumps during pressurization of the pipe section under test and the subsequent pressure test.
Page 21
5. Control panel Control panel plate Hazardous voltage inside. Risk of electric shock or burn. The control panel should only be removed by authorized electrical technicians.
Page 22
6. Industrial Keyboard Keyboard Note: No mouse is included. 7. Serial number label Serial number label...
Software First—check the computer’s time Time impacts data logging and reports Important: You cannot change the time zones, only the time. One easy step to check the time Window Window Second—zero the pressure...
Page 24
If the time is incorrect Set the time in Windows 10 End Test Date and time settings Time & Language...
Second—zero the pressure Zero the pressure Note: Since ambient air pressure depends on altitude and weather, you should use the PIT5000 application to zero for the current conditions. Setup PC Setup Zero Pressure Flexibility in the PIT5000 application No required edit boxes to fill-in...
Setup tab The Setup tab has five (5) sub-tabs the Setup sub-tabs Start Program Setup tab locked Setup Start Program Begin Test Note: The information remains viewable. A small button appears to the right of the main tabs. It has a down- arrow to view the various sub-tabs.
Page 27
Test Info sub-tab—Report 1 (the original report) Test Info sub-tab Report 1 Active Report Report 2. Test Info figure for Report 1 Change engineering units in Test Info Pressure Temp, Length Start Program Pressure psi, kg/cm , kPa, bar Temperature deg F, deg C Length feet, meters...
Page 28
Test Info sub-tab—Report 1 (continued) T-Pipe Required button T-Pipe Required T-Pipe Not Required Data Save Interval in minutes Data Save Interval in minutes Data Save Interval in minutes Examples: Data Reports 1 and 2...
Page 29
Pump Info sub-tab Enter pressure pump information Stroke Count Required Pump Model Number Pump Serial Number If the stroke count function is required Stroke Start Pressure Note: This number appears in the Stroke Start view-only box in the Test Limits sub-tab. Stroke Rate Target.
Page 30
Pump Info sub-tab (continued) If the stroke count function is not required Stroke Count Required Site Info sub-tab—Report 1 (the original report) Report 1 Report 1 Test Info Enter one pressure and several elevation points Note: The application uses this information to calculate the pressures at the other elevations.
Page 31
Note: The Test Time appears as Elapsed Time in the Data Panel after you click Start Program or Begin Test buttons PTest Instrument Pressure: PIT5000 Pressure Site Info Note: Once a test begins, the PTest edit box in the Data Panel flashes red when the pressure goes above or below the PTest Limits.
Page 32
PC Setup sub-tab The Get Cal Data button PC Setup Note: Measurement device serial numbers are not stored in the computer’s memory. They are retrieved from the measurement device each time you click the Get Cal Data button. The Communication Port Get Cal Data COM3...
Page 33
PC Setup sub-tab (continued) Build Report button...
Page 34
Locked data View locked information Setup Start Program Setup Note: The button is located to the right of the Stroke Count tab. Example of a locked data sub-tab Test Info Data Panel Note: the flashing red alarm in the Data Panel indicates the range is above or below the range that you specified.
Report 2—the enhanced report The advantage of Report 2 Test Info tab for Report 2 Report 2 Site Info tab for Report 2 Site Info Report 1 Next Site Info tab has a second page Back...
Data Panel (continued) What does the Data Panel display after you click the Start Program button? Note: This data is logged in a report. The stroke count would be included in the logged data at this time if you had entered that information in the Pump Info sub-tab.
Data Panel (Continued) What does the Data Panel display when a timed-test is complete? Time Complete Note: Data logging continues until you click the End Test button. The Data Panel also displays flashing red alarms Setup...
Add Note button What is the Add Note button? Add Note Start Program Begin Test When can notes be added? Note Add Note Note: A note has a limit of 60 characters. Add Note Data Notes Examples of notes added to the data log...
1. Yes, I want to STOP the test. Note: Clicking YES stops the test, saves the reports, and closes the PIT5000 application. The application will continue to display until the reports are saved. The longer the data log, the longer you will have to wait for the application to finish saving the files.
Strip Chart tab View a live plot of pressure and temperature Start Program Strip Chart Press T-Amb T-Pipe Strip Chart colors White Press T-Amb Green T-Pipe Strip Chart scales Temperature Pressure Time Begin Test Data Save Interval in Minutes Test Info Autoscale Graph On...
Data tab Data tab overview Between Start Program and Begin Test: Between Begin Test to Time Complete: Test Info After Time Complete: Data logging stops at End Test. Pressure Rate information Pressurization Testing Depressurization...
Details tab The Details tab Important: Live readings display in this tab only after you click Start Program. The Time boxes before “Start Program” Start Program The Time boxes between “Start Program” and “Begin Test” Time Start Time Estimated Finish Test Limits ...
Estimated Finish = Start Time + Test Time. Note: The Timed Test resumes until you reach the new Estimated Finish. Calibration data Start Program PC Setup sub-tab What does the path name mean? Details D:\PIT5000\Data. Test Info Mega Pipeline Section 103_ 08122016_ 0528_...
The tabular data Pump Info Stroke Start Pressure Stroke Rate Target Reset Connect your set of dry contacts Note: The PIT5000 supplies +5 V dc output to the dry contact set and counts pump strokes based on contact closures.
Stroke Count tab (continued) The function of the animated toggle switch Describing the animated toggle switch figure Counts A Counts B Note: When the toggle switch points right, then Counts A represents the previous interval stroke count and Counts B represents the current interval stroke count.
Stroke Count tab (continued) Counts A and Counts B Reset Reset Note: the Count Reset buttons do not affect the Total Count edit box. User Count User Count User Count User Volume User Counts A ...
Send the e-mail to: returnforms@meriam.com Return Material Authorization Do not send any unit for repair unless you contacted Meriam for a Return Material Authorization (RMA) number. Important: If you have not received this number and have not clearly marked it on the package being shipped back, we will return the unit at your expense.
Replace charger if needed. does not charge. operation (output should be 12 V dc). The PIT5000 power toggle switch Move the PIT5000 power toggle may be in the Off position. switch to the On position. Turn the The voltmeter on the computer on.
Page 54
Chart’s x-axis is Time zones are not used. Only computer clock for displaying incorrect. Universal Coordinated Time (UTC) time. is used. The PIT5000 Start the PIT5000 application Double click the PIT5000 icon on application did not manually. desktop. automatically start.
The PIT5000 application does not alert you to pressure limits. Stroke Counter PIT5000 supplies +5 V output to pump for Stroke Counter function. M12 connection to PIT5000 through the Meriam cable with number 8 spade terminals for connection to dry contacts.
Specifications (continued) Application update rates Strip Chart The Strip Chart updates once every two (2) seconds. Data Logging Between Start Program and Begin Test: Data is automatically saved in one-minute intervals. Between Begin Test to Time Complete: The green indicator appears in the Data Panel when a timed test is complete.
Part numbers Contact Meriam about these part numbers sales@meriam.com + 1 216 281 1100 (800) 817-7849 Part Descriptions Numbers Replacement parts Z9A686 Battery Charger Assembly. Z9A821 RTD Probe Assembly. Pt100, 4-wire, class A, Alpha Coefficent 0.003 85 Z9A1383 RTD Cable Assembly, 150 Ft.