Dometic HC302 Installation And Operating Manual

Health care refrigerator

Advertisement

Quick Links

PROFESSIONAL COOLING
PHARMACEUTICAL
HC302, HC502
Health care refrigerator
EN
Installation and Operating Manual. . . . . . . . 9

Advertisement

Table of Contents
loading

Summary of Contents for Dometic HC302

  • Page 1 PROFESSIONAL COOLING PHARMACEUTICAL HC302, HC502 Health care refrigerator Installation and Operating Manual..9...
  • Page 3 HC302, HC502 HC302FS HC302BIU HC502FS HC502BIU...
  • Page 4 HC302, HC502 chapter 6.3...
  • Page 5 HC302, HC502 chapter 6.3 chapter 6.3...
  • Page 6 HC302, HC502...
  • Page 7 HC302, HC502...
  • Page 8 HC302, HC502 HC302 chapter 6.3 FS: 450; BIU: 440 HC502 chapter 6.3 FS: 494; BIU: 484...
  • Page 9: Table Of Contents

    HC302, HC502 Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. Table of contents Explanation of symbols .
  • Page 10: Explanation Of Symbols

    Explanation of symbols HC302, HC502 Explanation of symbols DANGER! Safety instruction: Failure to observe this instruction will cause fatal or serious injury. WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury.
  • Page 11 HC302, HC502 Safety instructions • This device can be used by children aged 8 years or over, as well as by persons with diminished physical, sensory or mental capacities or a lack of experience and knowledge, providing they are supervised, or have been taught how to use the device safely and are aware of the resulting risks.
  • Page 12: Scope Of Delivery

    Scope of delivery HC302, HC502 NOTICE! • Do not use electrical devices inside the cooling device unless they are recommended by the manufacturer for that purpose. • Do not place it near naked flames or other heat sources (heaters, direct sunlight, gas ovens etc.)
  • Page 13: Intended Use

    HC302, HC502 Intended use Intended use The refrigerator is designed to store medicaments and medical products which may be stored at temperatures +2 °C and +8 °C. CAUTION! The refrigerator is not suitable for the storage of blood. Technical description Function description All materials used in the refrigerator are compatible for use with medicines.
  • Page 14: Installing And Connecting The Refrigerator

    Installing and connecting the refrigerator HC302, HC502 Control elements No. in fig. 1, Explanation page 3 Door lock Door Digital thermometer (see fig. 2, page 3) Cooling unit cover Drawers Interior light Foot frame Key to fig. 2, page 3 Explanation Current inner temperature (in °C)
  • Page 15 HC302, HC502 Installing and connecting the refrigerator Installing freestanding version Observe the following instructions when installing: • Install the refrigerator so that the warm air produced can easily flow away, either upwards or to the sides. • Leave the device to stand for at least four hours before you connect it to the power supply so that the refrigerant can flow back into the compressor.
  • Page 16: Using The Refrigerator

    Using the refrigerator HC302, HC502 ➤ Insert the battery into the thermometer (see chapter “Replacing the battery of the thermometer” on page 17). ✓ The display turns on. For the first two seconds the display will not show temperature values; it shows “--.-”.
  • Page 17 HC302, HC502 Using the refrigerator After the first start, after replacing the battery or after switching off the refrigerator for a longer time the display of the digital thermometer (fig. 2, page 3) shows the cur- rent ambient temperature. When the inner temperature reaches the operating range the thermometer should be reset to avoid showing wrong maximum temperature value.
  • Page 18 Using the refrigerator HC302, HC502 Defrosting the refrigerator NOTE In high ambient temperatures, the refrigerator may operate continuously, which can lead to excessive formation of frost on the rear wall of the refrigerator compartment. Humidity can cause frost to form in the interior of the refrigerator or on the vaporiser.
  • Page 19: Cleaning And Maintenance

    HC302, HC502 Cleaning and maintenance Removing the drawers You can remove the drawers, e.g for cleaning. Proceed as follows (fig. 0, page 7): ➤ Open the door (A). ➤ Pull out the drawer (B). ➤ Push the fixing pins from the outside to the inside (C) ➤...
  • Page 20: Troubleshooting

    Troubleshooting HC302, HC502 Troubleshooting Water in or under the refrigerator Fault Possible cause Remedy Water is leaking into the The condensate drain duct is clogged. Clean the drain. inside of the refrigerator. Medicines are preventing the water from Make sure that medicines do flowing to the collector.
  • Page 21: Warranty

    HC302, HC502 Warranty Warranty The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer. For repair and guarantee processing, please include the following documents when you send in the device: •...
  • Page 22: Technical Data

    Technical data HC302, HC502 Technical data HC302 HC502 Gross capacity: 33 l 49 l Capacity: 29 l 43 l Connection voltage: 220 – 240 V Energy consumption: 0.42 kWh/24 h 0.44 kWh/24 h Power consumption: 0.54 A Cooling capacity: +2 °C to +8 °C...
  • Page 24 Dometic (Pty) Ltd. Dometic Austria GmbH MEXICO Regional Office Neudorferstraße 108 Dometic Mx, S. de R. L. de C. V. South Africa & Sub-Saharan Africa A-2353 Guntramsdorf Circuito Médicos No. 6 Local 1 2 Avalon Road  +43 2236 908070 Colonia Ciudad Satélite...