- Install any fixed control at heigh of at least 1,5m and within sight of the door but away from mooving parts
- Make sur you have a second pedestrian access to your property.
Remember: in case of power failure or any problem with your opener you might be unable to operate it
from outside your property
- Save the unlocking key in a safe place out of reach of childrens, in order to permit to manually unlock
(from inside) the gate and operate it manually in case of power failure or other problem.
Ensure safety and prevent injuries:
- Place warning labels on the wall next to door control. permanently fix a label warning against entrapment
in a prominent place or just near any fixed control
- Without a properly working safety system, people (particularly small children) can be SERIOUSLY
INJURED or KILLED by a closing door. After installation ensure that the mechanism is properly adjusted.
- Never permit anyone to cross the path of a closing garage door. No one should go close to a stopped,
partially open door.
- Never leave children unsupervised near a door opener, whether moving, open, closed or stopped.
- Never permit children to play with the door opener's remote control buttons or transmitters, and do not
allow children to use them to operate the door opener.
Always keep remote controls out of reach of children.
- Install wall-mounted door controls (optional) out of the reach of children and away from moving parts of
the door.
- Always keep the door in sight until completely closed.
- While the door is closing, do not attempt to stop it by hand. This is extremely dangerous.
MOUNTING HARDWARE:
To compleete the installation you need following material:plastic hammer; pinching for Seeger; level; Cross
screwdriver PH2; flat screwdriver 2,5 mm; adjustable wrench; electric cable H07NRF length according to
the connection of the two actuators to the control box; 4 bolts for fixing plates with the gate with a diameter
8 mm length according to the thickness of the-gate; 4 bolts for fixing plates with the pillar with a diameter
8 mm length according to the thickness of the pillar; pinching; vice; cable clamp. Cables for additional
connections (0,5mm2)Prepare all the tools and material of use necessary to the installation. Tools must
be in perfect state and in conformity with the safety rules indicated by the national law.Prepare and install
an insulated underground ICT25 mm shealth to pass the actuator cable ( 2 X 1 mm2) to the contol box as
well as the photocells cables.
3. GENERAL INSTALLATION SCHEME ,PILLAR DIMENSIONS & STOP LIMITS
The diagram on page 3 shows an example of a typical automatic system.
Referring to this diagram, determine the approximate location where you will install each component
envisaged in the system and the most appropriate connection diagram.
The motors are to be connected with outdoor pole cable type H07NRF min. 0,75mmq
The accessories are connected with a bipolar outdoor cable min.0,35mmq
Useful components for an ideal automatic system:
1= Control box with containing electronic board with on board radio receiver, toroidal transformer, inner
battery compartment.
2 = actuators
3 = blinking light
4 = external antenna
5 = key switch
6 = radio remote control
7 = radio keypad
8 = solar panel
9 = pair of photocells ( receiver + transmitter)
WARNING: READ AND UNDERSTAND PAGE 4:
Pillar dimension, how to determinate measure A & B in case of gate opening towards inside or
outside, Gate stop limits.
For installation on gates opening to the outside, you need to use telescopic actuators and install referring
to the mounting scheme of fig.12 on pg. 6. Remember that with a gate opening towards the outside is
necessary to reverse the polarity of the motor cables (blue/brown cable). Check the feasibility of such
a system taking into account the overall dimensions. Make sure that the gate do not open onto a public
passageway. It is advisable to prepare a plant with safety photocells to be placed in such a way that the
doors, opening towards the outside do not create damages to things and people who are on the outside of
the property, such as parked vehicles.
4. POST MOUNTING BRACKETS (read carefully page 4)
4.1 – Pillar/ Coloumn/ fence post: determinate the position where to install the post mounting
bracket
According to the actuator model, and to the pillar dimension, calculate the ideal fixing position of the rear
bracket by consulting the installation schema of your actuator's model
HC312............page 5
HC418............page 9
HC412............page 6
HC518............page 10
HC512............page 7
HC618............page 11
HC612............page 8
EVO 700............page 14
EVE 900 FC...............page 16
EVO 700T .........page 15
EVE 900 T FC............page 17
The post bracket fixing position is extremely important as it shall determinate the gate opening angle and
speed and actuator thrust strenght. See the limit measures "A and "B"
Remind: with a high "B" measure, the opening will be slower. To fix the plate on the pillar use anchors
accordingly to the pillar construction material.
Take into account that the actuator must be installed perfectly horizontal and at a height such that the front
fixing plate corresponds to a reinforced area of the gate. It is recommended to install the actuator not less
than at 15cm from the ground.
Important! to allow a linear movement of the automation A & B measures should be similar.
Warning: if the structure is impossible to comply with the dimensions stated in the table ( ex. big masonry
pillar ), you will need to carry out masonry works to allow the correct positioning of the actuator.
4.2. FIx the bracket to the Pillar/ Coloumn/ fence post
Each actuator model is provided with specific brackets.
Mark middle of post bracket slots on pillar/ coloumn/ fence post.
Fix the bracket on the pillar. Use bolts anchors or screws suitable for the structure (tubular iron / pillar
masonry / concrete)
4.3 FIx the actuator to the post bracket:
Fasten the actuator to the bracket of the rear fixing with the pin and seal ring
- for EVE actuators see pag..19
- for "HC" actuators see pag.20
- for "SW" & EVO actuators see pag.21
SW400............page 12
SW400T..........page 13
25