MasterCool 53010 Manual page 2

Automotive nitrogen pressure regulator leak testing kit

Advertisement

• 100 - 4500 PSI (7 - 300 Bar) High side
• 30 – 1000 PSI (2 – 70 Bar) Adjustment range
• Integrated Shutoff Valve
Safety Relief Valve: 725 PSI (50 Bar)
Gauge Diameter: 2 5/8 (68 mm) Not including guard
WARNINGS
WARNING
• Only use with nitrogen gas (N2).
• The regulator is not to be used with liquid nitrogen.
Wear Safety Goggles
• Do not modify the regulator. Doing so could result in personal injury.
• Do not over-pressurize the regulator. This could cause leakage, part
damage or personal injury due to bursting of pressure-containing
parts.
• Keep the regulator clean and free of oil.
Avoid Contact with Refrigerant
• Do not use a damaged regulator. Except for replacing the gauges, do
not attempt to repair the regulator.
• Failure to follow instructions can result in personal injury and/or
damage to the equipment.
• Do not install this regulator where service conditions can exceed the
specifications of any applicable local, state, or federal codes and
regulations.
• Wear safety glasses and gloves.
REGULATOR CONNECTION AND USE
Note: The nitrogen regulator can be used with a charging hose and leak
testing gauge assembly or a charging and testing manifold.
• Make sure the cylinder connection (1) is clean and free from damage.
• Turn the T handle (6) all of the way out (counter clockwise, looking
from the bottom).
• Open the output control valve (4) to release any pressure, and then
close it.
• Install the nylon gasket or O-ring, if the connection requires one.
• Install the regulator onto the cylinder. Do not over tighten the nut on
gasketed connections.
• Connect the yellow charging hose (11) from the regulator to the leak
testing gauge assembly, making sure the ball valve connection (9) is
closed.
(If using a manifold, connect the yellow charging hose (15) of the
manifold to the regulator.)
• Connect the other end of the leak testing gauge assembly (8) to the
system.
(If using a manifold, connect the low side hose (14) from the manifold
to the system.)
• Slowly open the cylinder valve. The high side gauge (2) should read the
cylinder pressure.
• Adjust the regulator pressure by turning the T handle (6) clockwise
until the required pressure (based on the system's refrigerant) is
shown on the low side (output) (3) pressure gauge.
NOTE: This is a non-reliving regulator. To adjust the output pressure
lower, some nitrogen will have to be released from the output (e.g. with
no hoses connected, turn the T handle counter-clockwise, then open the
output control valve and close it. The output gauge should read a lower
pressure.)
• If using the leak testing gauge assembly, turn the red needle to the
required refrigerant pressure.
2
WARNING
Wear Safety Goggles
WARNING
Wear Safety Goggles
Avoid Contact with Refrigerant
Avoid Contact with Refrigerant