Klereo Kompact Installation Manuals

Klereo Kompact Installation Manuals

Swimming pool monitoring system
Hide thumbs Also See for Kompact:
Table of Contents

Advertisement

SWIMMING POOL MONITORING SYSTEM
Installation manual
Read carefully and keep for future reference. Please study the manual closely, before
bringing the system into service (Version 3)
1 - The content of this booklet may be modified without prior notice.
2 - Printing restrictions mean that the displays shown in this booklet may vary from those
actually appearing on the product.
3 - The content of this booklet may not be reproduced in any way without the manufacturer's
permission.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kompact and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Klereo Kompact

  • Page 1 SWIMMING POOL MONITORING SYSTEM Installation manual Read carefully and keep for future reference. Please study the manual closely, before bringing the system into service (Version 3) 1 - The content of this booklet may be modified without prior notice. 2 - Printing restrictions mean that the displays shown in this booklet may vary from those actually appearing on the product.
  • Page 2: Table Of Contents

    DDITIONAL POSSIBLE CONNECTIONS FOR THE DOUBLE RELAY OUTPUT ..........................21 ONNECTING THE HLRORINATOR 4.7.1 Connecting the cell to Klereo Salt ........................21 4.7.2 Connecting Klereo Salt to Klereo kompact......................22 4.7.3 Connecting K-link communication bus line .................... 22 ..............23...
  • Page 3 ..................................35 EATING 5.13.1 Heating set-up............................35 5.13.2 Adjusting target value for heating ......................36 5.13.3 Matching a Klereo Therm heating pump ....................36 5.14 S ................................39 ENSORS SET 5.15 P ........................... 40 RIORITIES AND SECURITIES SET 5.16 I ................................
  • Page 4: Klereo Kompact Models Description

    Klereo Kompact installation manual V 3 1. KLEREO KOMPACT MODELS DESCRIPTION Kompact regulates the filtering cycles depending on the water temperature and the pool characteristics (volume in m , power and flow rate of the filter pump). It regulates also the pH and disinfectant.
  • Page 5: Klereo Kompact Kits Contents

    A control box unit equipped with 1 or 2 metering pumps according to the selected disinfectant system • 1 Salt Chlorinator for the Klereo Kompact Salt (delivered in a separate box)) • A flow switch sensor mounted on a Ø 50mm T shape collar (for Ø 63mm tube, please order the reference KL10-PCS63) •...
  • Page 6: Usage Limitations

    Pool containing no more than 200 m water by volume. – The Klereo Kompact control box unit is not fitted with electrical modules to drive – directly the filter pump. You need to make the connection with the filter pump control box equipped with a thermal overload circuit breaker and a contactor.
  • Page 7: Installation Diagram

    Klereo Kompact installation manual V 3 3.2 Installation diagram: Figure 5. Kompact installation diagram The flow switch and water temperature sensor as well as pH and ORP probes must be installed: o After the filter o Before the heating system (Heating pump or heat exchanger) as well as before the water treatment injection points or the Salt Chlorinator cell.
  • Page 8: Hydraulic Accessories Positioning

    Klereo Kompact installation manual V 3 3.3 Hydraulic accessories positioning 3.3.1 Holding collars (optional) Install the collars directly onto the existing pipe. There are 2 models: Ø 50mm or Ø 63mm. Probes must be relatively close to each other. Drill a 13mm hole for the probes...
  • Page 9: Fixing The Probes

    Klereo Kompact installation manual V 3 Figure 9. Positioning the probes in the chamber of analysis 3.4 Fixing the probes. The necessary parts to fix the pH, ORP probes and water temperature sensor are detailed as follows: a : probe-holder upper part...
  • Page 10: Installing The Flow Switch

    Klereo Kompact installation manual V 3 3.5 Installing the flow switch The flow switch sensor is factory delivered together with a Ø 50mm T shape collar for mounting. To fix it, cut the pipe to a length of 30 mm. It is very important to respect the right direction by checking the arrow representing the water stream flow.
  • Page 11: Connecting The Pipes Of The Metering Pumps

    Klereo Kompact installation manual V 3 3.6 Connecting the pipes of the metering pumps Transparent Rigide semi- flexible opaque pipe pipe (PVC) (PE) Drawing strainer Injector valve Reducer ½ - 3/8 Figure 14. Metering pump kit presentation Insert both pipes onto the metering pump (check the arrows showing the direction of input of...
  • Page 12: Installing The Water Treatment Tanks And Injections

    Check that the holding collars used to inject the products are sealed. The room must be ventilated. Keep a minimum distance of 1 m between the tanks and the Klereo components, to avoid fumes from the products damaging the system.
  • Page 13 The holding collars used for injecting products must be placed at the end of the filtering circuit before the backflow. Maximum distances between Klereo control box unit and the tanks or the injection points are 2m maximum. Minimum distance between 2 injection points is 40cm.
  • Page 14: Installing The Solenoid Valve For Kompact With Bromine Or Chlorine Tablets

    3.8 Installing the solenoid valve for Kompact with Bromine or Chlorine tablets The Kompact for Bromine regulates disinfection by opening a solenoid valve letting the water going through a brominator filled with bromine or a chlorinator filled with Chlorine tablets.
  • Page 15: Installing The Cell With Klereo Salt Chlorinator

    Install manual valves at the by-pass level for easy maintenance. 3.9 Installing the cell with Klereo Salt Chlorinator The cell is supplied together with the Salt Chlorinator control box unit in a separate parcel. Allow a maximum distance of 1.5m between the cell and the control box unit (it is actually the length of the cable between the 2 units).
  • Page 16: Electrical Installation

    Installation of the Salt Chlorinator cell 4. Electrical installation 4.1 Connecting the sensors Ph and ORP probes, water temperature and flow switch sensors must be connected to the appropriate inputs on the Kompact control box unit as shown below: ORP probe pH probe Connector...
  • Page 17: Connecting The Power Supply

    Klereo Kompact installation manual V 3 IMPORTANT The Kompact salt and active Oxygen kits do not use ORP probe. In order to avoid measure disturbances, do not remove the 50 Ohm plug connected to 4.2 Connecting the power supply the control box unit.
  • Page 18 Kompact control box unit. 3 – The R and RN output is according to the Kompact model: - Connected to the other metering pump located in the front panel of the Kompact liquid Chlorine or active Oxygen control box unit.
  • Page 19: Connecting Filtering

    This output is a normally open contact. The power supply going through should not exceed 10A. Make sure that the electrical circuit is equipped with necessary protections meeting local standards. IMPORTANT Never connect the filter pump directly to Klereo Kompact control box unit V1-V2 inputs. Set the filtering switch in Auto mode...
  • Page 20: Connecting Lighting

    Klereo Kompact installation manual V 3 Figure 29. Example of connection to an existing swimming pool control box unit. 4.5 Connecting lighting The lighting output (M1 M2) must be connected to the electrical circuit supplying the pool lighting transformer. This output is a normally open contact. The power supply going through should not exceed 8A.
  • Page 21: Additional Possible Connections For The Aux Bdouble Relay Output

    Klereo Kompact installation manual V 3 Additional possible connections for the Aux B double relay output. The auxiliary equipment must be connected either to the output K – KN or to the output M1 and M2. The following diagram shows both types of wiring according to the auxiliary equipment amperage.
  • Page 22: Connecting Klereo Salt To Klereo Kompact

    Klereo Salt circuit board is inside Klereo Salt control box unit. Once the wiring is done and when starting-up, if the following message appears: Match Chlorinator, it means that Klereo Salt is not matched with Klereo Kompact. If so, proceed as follows: 1.
  • Page 23: Connecting The Transformer And The Solenoid Valve For Kompact Bromine

    For the connection, you must have the heating system electrical and technical diagrams. 4.10 220V input – IJ input Klereo Kompact control box unit has a 220V input for a monitoring of lighting or filtering outside Klereo in a slave mode.
  • Page 24: Contacts Inputs

    Klereo Kompact installation manual V 3 filtering. Please contact after sales service department for further information on this working mode. • The different working modes for the double relay output for lighting (K/KN +M1 M2) or Aux B are those of a switch: - Either «...
  • Page 25: Start Up

    Steady green when the Kompact control box unit is power supplied and filtering, pH and disinfectant regulation is possible. Flashing red when the Kompact control box unit is power supplied and there is a fault. Refer to the menu « message » to know the fault.
  • Page 26: Main Menu

    Klereo Kompact installation manual V 3 The values of the pH, air and water temperature sensors flash when filtering is stopped. Their display is steady when filtering is running for at least 10 min. Wait for 30 to 90 min with ORP.
  • Page 27: Entering Pool And Filtering Characteristics

    Pump power Mid-day Filtering For the best Klereo regulation performance, it is very important to enter the right characteristics: pool water volume and the filter pump flow rate. The filtering mode can be regulated automatically by Klereo (regulation according to water temperature, pool volume and filter pump flow rate), programmed with time slots or manual ON/OFF).
  • Page 28: Calibration And Checking Of Probes

    Rinse and insert the probe into the probe holder, then place it in its base if OK. After this operation, check the value shown on the Klereo unit when the probe is dipped in water (between pH7 and pH8) Press...
  • Page 29: Checking Orp Probe (When Used)

    5.6 Regulations test Now that all parts of the Klereo Kompact are in place, the various regulations must be checked. Use the button keys below the display to check operation of filtering, lighting and auxiliary A.
  • Page 30: Disinfectant Set-Up

    Water treatment Advanced param. Disinfectant type Liquid Chlorine Klereo1 Salt Chl. Klereo2 Salt Chl. Other Salt Chl. Active Oxygen Bromine None The default disinfectant is the one as ordered. For a non Klereo Salt Chlorinator, select « other Salt Chlor”...
  • Page 31: Ph Correcting Agent Set-Up

    Klereo Kompact installation manual V 3 “Klereo Salt Chlor 1” is a basic Salt Chlorinator no more available for sale. If you have bought a Kompact Salt, it is delivered with a more sophisticated model. Select as disinfectant « Klereo Salt Chlor 2 ». Select then the Klereo Salt Chlorinator model (KL50-S15, KL50- S20, and KL50-S25 ;…) by pressing the screen selection key below «Model».
  • Page 32: Ph Target Value

    When doing the installation, the measured Chlorine concentration must be between 1 and 3mg/l and the Bromine one between 1 and 2 mg/L. Klereo do not measure free Chlorine but the ORP value. To increase or decrease the disinfectant concentration, modify the ORP target value accordingly.
  • Page 33: Orp Security

    Modifying the regulated mode c. ORP security There is an adjustable ORP security when using a Salt Chlorinator treatment (whatever the model, Klereo or another brand) in order to stop Chlorine production when reaching a maximum value. The default value is 800mV.
  • Page 34: Outputs Assignment

    We advise that you program 2 hours filtering cycles minimum. 5.12 Outputs assignment Klereo Kompact outputs are default set up when delivered. Specify the type of equipments connected to the Klereo Kompact system by going to the menu ”Output assignment”. Outputs assignment...
  • Page 35: Heating

    Important: only assign P-Q output as heating in case of « other heating ». When using a Klereo heating pump, you only have to connect the “lin” bus (refer to § 5.13.3). Two « heating » sub-menus are available, one to select the type of heating (go to menu...
  • Page 36: Adjusting Target Value For Heating

    Klereo Kompact installation manual V 3 • Klereo Therm: to select when using a Klereo heating pump that can then be controlled from both the Kompact control box and the Klereo Therm display (refer to the Klereo Therm heating pump manual).
  • Page 37 To match the Klereo Therm heating pump, proceed as follows: 1- Press the orange matching key button (as shown on picture 52) on the Klereo Therm circuit board till LED 2 flashes rapidly then stops and after LED 1 flashes rapidly.
  • Page 38 Klereo Kompact installation manual V 3 Wiring N° 2 and N° 3: Klereo Salt Chlorinator and Kle reo Therm In that case, there are 2 possibilities to connect the Klereo Therm. Matching procedure will remain the same in both wiring cases.
  • Page 39: Sensors Set-Up

    To match the Klereo Salt Chlorinator and the Klereo Therm heating pump together, proceed as follows: For Klereo Salt Chlorinator: 1. Press the orange matching key button (as shown on picture 55) on the Klereo Salt Chlorinator circuit board till LED 2 flashes rapidly. 2. Release the key button 3.
  • Page 40: Priorities And Securities Set-Up

    Default selected when delivered. This two treatment priorities are inactive when Klereo is in “Eco mode”. Boost treat. priority: this option starts immediately the disinfectant boost treatment during 24h and therefore forces filtering.
  • Page 41: Flow Switch

    • Authorize filtering: authorize filtering in case of 220V input (useful when using automatic valve for backwash system) • Slave filtering: to use the Kompact control box unit in slave mode. In this setting-up, filtering is ON when there is 220V input and OFF on the contrary.
  • Page 42: Selecting The Control Modes

    Klereo Kompact installation manual V 3 Figure 56. Outputs setting screens Browse: Definition Used to confirm the change of programming mode and perform the following actions: Stop in manual mode, modify in time slot or timer mode and info in...
  • Page 43: Appendix 1: Menu Map

    Klereo Kompact installation manual V 3 APPENDIX 1: MENU MAP List of messages if Water Kompact pH Kompact ORP Kompact Resynchronisation Sensors validation Regulated Filtering mode Time slots Manual Fill in the value Pool volume Filter pump flow rate Fill in the value...
  • Page 44 Klereo Kompact installation manual V 3 Select Ph probe pH Kompact Select Water temp Water temp. Kompact pH concentration Treat. concentration Boost treat. timelag Balanced pH Calculated from and TH values Heating mode if “other Fill in target value heating”...
  • Page 45 Klereo Kompact installation manual V 3 Messages List of messages Set the date Set the time Interface Language Privilege keylock Contrast Display settings Set-up ON/OFF sensors Water pH tank Treatment tank Pool cover Equipments Indoor Pool Pool cover Pool cover polarity...
  • Page 46 Klereo Kompact installation manual V 3 Slave Filt Priorities / securities Pump protection pH priority Disinfectant priority Boost treat. priority Heating priority Radio matching Tests / Installation Regulation tests Input status Software version. Control box update Display update Save all...
  • Page 47: Appendix 2: Active Chlorine According To Free Chlorine And Ph Levels (Water At 25°C Without Stabilizer)

    Klereo Kompact installation manual V 3...
  • Page 48 Klereo Kompact installation manual V 1.1 5 rue du Chant des Oiseaux 78360 MONTESSON FRANCE Email: contact@klereo.com Tel.: +33 130 15 78 14...

Table of Contents