Electrical Connection - Summit CREK2B Instruction Manual

2-burner electric cooktops
Table of Contents

Advertisement

ELECTRICAL CONNECTION

The electrical connection must be performed by a qualified technician. The connection must comply
with all local, state and national standards and regulations.
Electrical Requirements
Power supply
Circuit
Minimum
Conduit
Model
input
breaker
wire size
size
CREK2B
200-240 V AC
¾"
15 Amp
16 AWG
50/60 Hz
CREK2W
You can find the identification plate with the electrical specifications on the underside of the
appliance
Identification
plate
Connect Electrical Supply
WARNING: Disconnect power before servicing.
The electrical power supply should be a 1-phase, 3-wire system with ground connection. Install
suitable junction box (not furnished). Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit connector.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
Black (L1) to black
Red (L2) to red
Green (ground) to ground.
WARNING: Always connect the ground wire.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Crek2w

Table of Contents