AC Line Filter Specifications

AC Line Filter
Voltage
Cat. No.
Rating
2198-DB08-F
2198-DB20-F
480V AC
2198-DB42-F
three-phase
50/60 Hz
2198-DB80-F
2198-DB290-F
(1) Tolerance for this value is +10%.

Additional Resources

These documents contain additional information concerning related products from
Rockwell Automation.
Resource
Kinetix 5700 Servo Drives User Manual,
publication
2198-UM002
Kinetix 5500 Servo Drives User Manual,
publication
2198-UM001
System Design for Control of Electrical Noise Reference Manual,
publication
GMC-RM001
EMC Noise Management DVD, publication GMC-SP004
Industrial Automation Wiring and Grounding Guidelines,
publication
1770-4.1
Product Certifications website,
You can view or download publications at http://www.rockwellautomation.com/literature. To
order paper copies of technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.
Rockwell Automation maintains current product environmental information on its website at
http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, Kinetix, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 2198-IN003B-EN-P - March 2015
Supersedes Publication 2198-IN003A-EN-P - July 2012
Current Rating
A @ 50 °C (122 °F)
7.5
20
(1)
42
80
290
http://www.ab.com
Power Loss
Leakage
@ Rated Current
Current, typ
W
mA
3.6
2.5
5.1
5.2
14.7
4.0
18.3
13.0
32.7
19.4
Description
Information on installing, configuring, starting, and
troubleshooting your Kinetix 5700 servo drive system.
Information on installing, configuring, starting, and
troubleshooting your Kinetix 5500 servo drive system.
Information, examples, and techniques designed to
minimize system failures caused by electrical noise.
Provides general guidelines for installing a Rockwell
Automation® industrial system.
Provides declarations of conformity, certificates, and other
certification details.
Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Weight,
Operating
approx
Temperature
kg (lb)
0.77 (1.70)
1.63 (3.59)
0...50 °C
2.70 (5.95)
(32...122 °F)
3.95 (8.71)
4.20 (9.26)

Advertisement