Service Connections - Cleveland Steamcraft II Service Manual

Table of Contents

Advertisement

Cleveland Range Company equipment is designed and built to comply with applicable standards for manufacturers. Included among
those certification agencies which have approved the safety of the equipment design and construction are: UL. A.G A., NSF, ASME,
CSA, CGA, and others.
Cleveland Range Company equipment is designed and certified for safe operation only when permanently installed in accordance with
local and/or national codes. Many local codes exist, and it is the responsibility of the owner and installer to comply with the
In no event shall Cleveland Range Company assume any liability for consequential damage or injury resulting from installations which
are not in strict compliance with our installation instructions. Specifically, the Cleveland Range Company will not assume any liability
for damage or injury resulting from improper installation of equipment, including, but not limited to. temporary or mobile installations
Ref. No.
Qty.
Description
1
1
Ground lug for ground w connection
2
1
terminal block for feed wire connection
3
1
Feedwire knockout hole—
4
2
Fuse holders with 2 amp type KTKR-2
fuses (Part No 06344)
5
1
6
1
Drawn plumbing
7
2
Venting outlets—No connections or re-
strictions should be made
ELECTRICAL
Install in accordance with local codes and/or the National Electric Code ANSI/NFPA No 70-1984 (USA) or the Canadian Electri-
cal Code CSA Standard C22.1 (Canada). A separate fused disconnect switch must be supplied and installed. The steamer must be
eiectncally grounded by the installer.
The electric supply must match the power requirements specified on the steamer's rating label. The copper wiring must be
adequate to carry the required current at the rated voltage.
Locate the terminal block cover and "knock-out" plug at the upper left corner of the steamer's back panel. Remove the two screws
securing the terminal block cover and remove the cover. Remove the "knock-out" plug. Feed permanent copper wiring through the
"knock-out." and fasten to the terminal block, in accordance with the wiring diagram affixed to the steamer's back panel. Be sure
to connect the ground wire to the separate ground terminal connecfor (ground lug). Replace the terminal block cover and secure it
with the two screws.
The steamer is— wired for 3-phase delta operation at the facfory. For single phase operation, the installer must change the
Two jumpers on the terminal block to that shown in the accompanying diagram (and on the steamer's wiring diagram label.)
two jumpers on the terminal block to that shown in the accompanying diagram (and on the steamer's winng diagram label)
1 PHASE
AMPS AWG
VOLTS
Watts
206
5000
24
220
4202
19
240
5000
21
410
-
-
WATER
A 1/4" * IPS COLD water line is required. DO NOT USE HOT WATER. Minimum water pressure is 35 psi (2 4 kg/cm2), the
maximum water pressure is 60 psi (4.1 kg/cm2), measuring flow pressure, not static pressure Connect the cold water line to the
input side of the line strainer, located on the outside of the steamer's back panel, toward the top-center of the panel Refer to the
service connection drawing for precise location.
RECOMMENDED PLUMBING (furnished by the installer):
Shut-off Valve' The water supply can be shut off at this valve in the event that the steamer, or a plumbing component, requires service

SERVICE CONNECTIONS

3 PHASE
60 HZ-3 Wire—
WATT
AMPS AWG
S
10
5000
14
14
SUPPLY USE
10
4202
11
14
COPPEB WIRE
ONLY SUITABLE
10
5OOO
12
14
FOR AT LEAST
-
5000
6
14
75 Degrees C