Advertisement

Title
f107
Analog input terminal selection (VIB)
f210
VIB input point 1 setting
f211
VIB input point 1 frequency
f212
VIB input point 2 setting
f213
VIB input point 2 frequency
f216
VIC input point 1 setting
f217
VIC input point 1 frequency
f218
VIC input point 2 setting
f219
VIC input point 2 frequency
f389
PID control reference signal selection
3) Preset speed
[Example of process value setting]
Condition: Pressure control as PID control.
Input the feedback signal of 1 to 2 atm into Terminal VIC by 4 to 20mA signal.
Input the process value into Terminals S1 and S2 by preset speed 1, 2, and 3 settings.
Feedback value
2 atm
1.5 atm
1 atm
4mA
Pressure
Feedback value
(atm)
(4-20mA)
1
1.25
1.5
1.75
2
Title
sr1
Preset speed frequency 1

Preset speed frequency 2

Preset speed frequency 3
f114
Input terminal selection 4A (S1)
f115
Input terminal selection 5 (S2)
f216
VIC input point 1 setting
f217
VIC input point 1 frequency
f218
VIC input point 2 setting
f219
VIC input point 2 frequency
Note) Input process value needs to be less than maximum feedback value.
Function
Feedback value
(Converted frequency)
60Hz
0Hz
20mA
4mA
Preset speed
1 to 3
4
-
8
1
12
2
16
3
20
-
Function
Setting (Example)
0:0-+10V
0(%)
0(Hz)
100(%)
60(Hz)
20(%)
0(Hz)
100(%)
60(Hz)
2: Terminal VIB
Process value
(Converted frequency)
Preset speed 3: 45Hz (1.75 atm)
Preset speed 2: 30Hz (1.5 atm)
Preset speed 1: 15Hz (1.25 atm)
20mA
Process value
S1
S2
terminal
terminal
-
-
ON
OFF
OFF
ON
ON
ON
-
-
Setting (Example)
15(Hz)
30(Hz)
45(Hz)
10: Preset speed 1
12: Preset speed 2
20(%)
0(Hz)
100(%)
60(Hz)
14
E6581879
Converted frequency
(Hz)
0
15
30
45
60