Inova SV 125 Operating Manual page 150

Fully automatic filling and closing machine for syringes
Table of Contents

Advertisement

Pick up nest nest speed [%]
Entry of the speed with which the nest pick--up device moves to pick--up position.
Lay down XY position [mm]
Entry of the position of the nest pick--up device when placing a nest on the nest
transport table.
Lay down XY speed [%]
Entry of the speed with which the nest pick--up device moves to lay--down position.
Delay lay down XY [ms]
Entry of the delay when placing a nest on the nest transport table.
Changing a parameter
Determine the value through teach--in, see chapter 5.2.60, page 5--137.
1
Touch the input field of the parameter that should be changed.
2
Enter the determined value on the keyboard.
3
Touch control field
4
Control field
The machine drive is switched off.
Screen Format input - - Menu teach servo axes is called up.
Screen Format input - - Pick- -up station [help] is called up.
Screen Main screen is called up.
The previous screen is called up.
Screen Format input - - Pick up station [2/2] is called up.
Version 1.0
5--64
on the keyboard to take over the entry.
Function
Operation
SV 125