MM series
4 Regulation Use
Kobold level transducers are used for the continuous level indication and level
control of all kinds of liquids. The simple design with only one moving part (the
float) is suitable for applications that demand reliability. Kobold level transducers
allow the continuous level indication and level control of liquids unaffected by
electrical conductivity, temperature, pressure. The level transducer may only be
used in liquids that will assure free movement of the float. The following points
must be noted:
no large particles
density of the fluid must not be less than that specified for the float type
pressure and temperature to be held within the limits given in the technical
specifications
A variety of transducers in various designs, connecting configurations and
materials are available for the acquisition of the measuring values.
Attention! These units should not be installed in the vicinity of strong
magnetic fields, since this can impair their intended functionality.
5 Float designs
Model
Form
Cylinder
MM05
hollow
Cylinder
MM07
hollow
Cylinder
MM08
hollow
Ball
MM10
hollow
Cylinder
MM13
hollow
Cylinder
MM15
hollow
Cylinder
MM16
hollow
Ball
MM20
hollow
page 4
Float
Materials
Outside
[mm]
PP
42
PVC-U
42
St. steel
44
1.4404
St. steel
52
1.4404
PVDF
38
PP
60
PVC-U
60
St. steel
95
1.4404
Bore
Min. Liquid
Height
Hole
Density
[mm]
[mm]
[kg/dm³]
40
14
> 0.6
40
14
> 0.9
52
15
> 0.65
52
15
> 0.6
60
18
> 0.6
60
18
> 0.4
60
18
> 0.6
95
20.8
> 0.5
Nominal
Max.
Pressure
Temperature
[bar] at
°C
20 °C
-10...+80°C
3 bar
0...+60 °C
3 bar
-20...+130°C
20 bar
-20...+130°C
30 bar
-10...+125°C
2 bar
-10...+80ºC
6 bar
0...+60°C
3 bar
-10...+130°C
15 bar
DT0593