Regulation Use; Float Designs - Kobold MM Series Operating Instructions Manual

Liquid level transducer
Table of Contents

Advertisement

MM series

4 Regulation Use

Kobold level transducers are used for the continuous level indication and level
control of all kinds of liquids. The simple design with only one moving part (the
float) is suitable for applications that demand reliability. Kobold level transducers
allow the continuous level indication and level control of liquids unaffected by
electrical conductivity, temperature, pressure. The level transducer may only be
used in liquids that will assure free movement of the float. The following points
must be noted:
 no large particles
 density of the fluid must not be less than that specified for the float type
 pressure and temperature to be held within the limits given in the technical
specifications
A variety of transducers in various designs, connecting configurations and
materials are available for the acquisition of the measuring values.
Attention! These units should not be installed in the vicinity of strong
magnetic fields, since this can impair their intended functionality.

5 Float designs

Model
Form
Cylinder
MM05
hollow
Cylinder
MM07
hollow
Cylinder
MM08
hollow
Ball
MM10
hollow
Cylinder
MM13
hollow
Cylinder
MM15
hollow
Cylinder
MM16
hollow
Ball
MM20
hollow
page 4
Float
Materials
Outside
 [mm]
PP
42
PVC-U
42
St. steel
44
1.4404
St. steel
52
1.4404
PVDF
38
PP
60
PVC-U
60
St. steel
95
1.4404
Bore
Min. Liquid
Height
Hole 
Density
[mm]
[mm]
[kg/dm³]
40
14
> 0.6
40
14
> 0.9
52
15
> 0.65
52
15
> 0.6
60
18
> 0.6
60
18
> 0.4
60
18
> 0.6
95
20.8
> 0.5
Nominal
Max.
Pressure
Temperature
[bar] at
°C
20 °C
-10...+80°C
3 bar
0...+60 °C
3 bar
-20...+130°C
20 bar
-20...+130°C
30 bar
-10...+125°C
2 bar
-10...+80ºC
6 bar
0...+60°C
3 bar
-10...+130°C
15 bar
DT0593

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mm05Mm07Mm08Mm13Mm15Mm16 ... Show all

Table of Contents