Removal of Fan Motor

4. Removal of Fan Motor
Procedure
Step
Remove the 2 lower
1
screws of the fan motor.
2
Remove the 2 upper
screws.
3
Remove the fan motor.
26
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
2
1
Fan motor
(R10414)
Be sure to remove the lower
screws first. If the upper
screws are removed first, the
fan motor may tilt or fall
because the center of its
gravity is toward the front.
It may cause injuries.
(R6442)
When reassembling, be sure
to place the wire harness
lower.
(R10542)
Si121176
Points
Harness
(R6444)