Problem: Kiln switch box ½
amp fuses keep blowing.
What size fuse are you using? Correct fuse:
AGC ½ A 250V AC
If the fuse is the correct size, perform the following test:
Kiln Switch Box ½ Amp Fuse Power Test
UNPLUG the kiln/disconnect the power. Remove
the 4 screws holding the controller board faceplate
to the switch box. Lift faceplate out of box and let the
board hang on the outside of the box with the back
of the board facing you. Disconnect both wire plugs
from the back of the controller. Then plug the kiln
back in. Apply power to kiln. If the ½ amp fuse
blows, replace the transformer. (If the fuse does not
blow, the problem is a board or relay. Go to step 2.)
Connect the INPUT plug (orange, blue, and white
wires) to the board again. Leave off the OUTPUT
wire plug (the one with the red and black wires).
Program the controller to fire to 1000°F at FULL
rate in Ramp-Hold mode. Press
blows, replace or service the board. (If the fuse does
not blow, the problem is caused by a short in the coil
of a relay. Go to step 3.)
UNPLUG kiln/disconnect power. Reconnect the
OUTPUT wire plug. Reinstall the board in the
switch box. Replace the relay.

Index

Add Hold Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
bAdP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
calibrating the controller . . . . . . . . . . . . . . . . . . . . . . . . 12
casting temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
clicking sound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 8, 14
cooling segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CPLt (complete) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Delay timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
display dot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3, 13
editing target temperature . . . . . . . . . . . . . . . . . . . . . . . . 9
element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
EtH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
FAIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
FE error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
figuring firing time of a segment . . . . . . . . . . . . . . . . . . . 5
FtL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13, 15
hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 6
HtdE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
lost wax burnout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PF 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PF 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PF 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
power failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 12
power surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Program Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ramp-Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
repeating a firing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
scrolling numbers rapidly . . . . . . . . . . . . . . . . . . . . . . . . . 4
Single Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Skip Segment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
tC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
tCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
tCOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
tCr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
temperature display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
temperature over-shoot . . . . . . . . . . . . . . . . . . . . . . . . . . 6
temperature, °F and °C. . . . . . . . . . . . . . . . . . . . . . . . 3, 13
thermocouple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3, 11
thunder storms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
time display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. If the fuse
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents