Valeo SC600 Revo-E Byd Hybrid Operating Instructions Manual

Bus body electronics

Advertisement

Quick Links

BUS BODY ELECTRONICS
SC600 REVO-E BYD HYBRID
Operating instructions
- Busdriver
Rev. 21.11.2018
Id.No. DOK30609

Advertisement

Table of Contents
loading

Summary of Contents for Valeo SC600 Revo-E Byd Hybrid

  • Page 1 BUS BODY ELECTRONICS SC600 REVO-E BYD HYBRID Operating instructions - Busdriver Rev. 21.11.2018 Id.No. DOK30609...
  • Page 2: Table Of Contents

    BUS BODY ELECTRONICS Contents Contents List of Figures List of Tables Introduction Intended purpose Symbols used Description of the control panel Description of the display Mode overview Activation/deactivation 2.1.1 Activation 2.1.2 Deactivation Auto mode 2.2.1 Activation 2.2.2 Deactivation Configuring the blowers manually Fresh air/recirculating air function Dehumidify Setting the temperature...
  • Page 3: List Of Figures

    BUS BODY ELECTRONICS List of Figures Figure 1 - SC600 control panel .................. 4 Figure 2 - SC600 display ..................4 Figure 3 - SC600 mode overview ................5 Figure 4 - SC600 start display ................... 6 Figure 5 - SC600 deactivation ................... 6 Figure 6 - SC600 Auto mode activated ................
  • Page 4: Introduction

    BUS BODY ELECTRONICS 1 Introduction 1.1 Intended purpose The SC600 is a system intended to control the HVAC components (heating, ventilation, air - conditioning) in buses, for example roof-top air-condition systems, heating devices, etc. It con- sists of a control panel (control device as an interface between human and machine) that is integrated into the dashboard.
  • Page 5: Description Of The Control Panel

    BUS BODY ELECTRONICS 1.3 Description of the control panel The control panel components are depicted and described in the following image. Figure 1 - SC600 control panel 1. Display 5. Function status light 2. On/off button 6. Blower button 3. UP 7.
  • Page 6: Mode Overview

    BUS BODY ELECTRONICS 1.5 Mode overview The SC600 system includes 2 different modes – Operating mode and Error mode. SC600 Error detection Operating mode: Includes all of the mode: Mode to display all functions and infor- errors that occurred mation summarized and their probability under point 2 as of occurrence.
  • Page 7: Use

    BUS BODY ELECTRONICS 2 Use 2.1 Activation/deactivation 2.1.1 Activation Press button ➔ Sets the last configured temperature; Auto mode off Figure 4 - SC600 start display (Figure 4). 2.1.2 Deactivation Press button ➔ Display deactivated. Press button for 2 seconds until OFF appears ➔...
  • Page 8: Deactivation

    BUS BODY ELECTRONICS 2.2.2 Deactivation Press button if Auto mode is on ➔ Mode is off - corresponding status light and function symbol are off (Figure 9). Note Figure 9 - SC600 Auto mode deactivated When Auto mode is deactivated, the air conditioning com- pressor (after a run time of 90 seconds max.) and the heater are turned off.
  • Page 9: Dehumidify

    BUS BODY ELECTRONICS 2.5 Dehumidify Press button for 2 seconds ➔ Dehumidify air function is on (Figure 11). Note Figure 11 - SC600 dehumidify activated Dehumidify can only be activated when Auto mode is on. 2.6 Setting the temperature Press button ➔...
  • Page 10: Error Overview

    BUS BODY ELECTRONICS ➔ Reset the counter with (after resetting, the coun- ter shower the value 1 if the error persists). 2.7.1.3 Ending Press buttons for 2 seconds ➔ Normal operating display appears (Figure 15). Figure 15 - SC600 normal operating display 2.7.2 Error overview...
  • Page 11 Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 – 82198 Gilching - Germany - Tel. +49 (0)8105 7721-0 - Fax 49 (0)8105 7721-889 www.valeo-thermalbus.com - service-valeobus@valeo.com...